[ARM] pxa/hx4700: fix hx4700 touchscreen pressure values
hx4700 touchscreen events were being dropped in ads7846_rx() because their pressure values consistently exceeded the platform maximum of 512; a sample of 256 pressure values were in the range 531 to 815. Doubling the platform maximum to 1024 allows hx4700 touchscreen events to pass the test. Signed-off-by: Paul Parsons <lost.distance@yahoo.com> Signed-off-by: Eric Miao <eric.y.miao@gmail.com>
This commit is contained in:
parent
9da4ea69f2
commit
10d5d99e88
|
@ -604,7 +604,7 @@ static struct platform_device gpio_vbus = {
|
|||
static const struct ads7846_platform_data tsc2046_info = {
|
||||
.model = 7846,
|
||||
.vref_delay_usecs = 100,
|
||||
.pressure_max = 512,
|
||||
.pressure_max = 1024,
|
||||
.debounce_max = 10,
|
||||
.debounce_tol = 3,
|
||||
.debounce_rep = 1,
|
||||
|
|