[ALSA] ice1712 - Fix word clock status control on Delta 1010LT
The 'Word Clock Status' control on Delta 1010LT checks the CS8427 error register too strictly and almost always returns 1 (unlocked). It should check only the lock status bit. Signed-off-by: Takashi Iwai <tiwai@suse.de> Signed-off-by: Jaroslav Kysela <perex@perex.cz>
This commit is contained in:
parent
7829d0eccb
commit
1005f66fd7
|
@ -405,7 +405,7 @@ static int snd_ice1712_delta1010lt_wordclock_status_get(struct snd_kcontrol *kco
|
|||
if (snd_i2c_sendbytes(ice->cs8427, ®, 1) != 1)
|
||||
snd_printk(KERN_ERR "unable to send register 0x%x byte to CS8427\n", reg);
|
||||
snd_i2c_readbytes(ice->cs8427, ®, 1);
|
||||
ucontrol->value.integer.value[0] = (reg ? 1 : 0);
|
||||
ucontrol->value.integer.value[0] = (reg & CS8427_UNLOCK) ? 1 : 0;
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in New Issue