ASoC: kirkwood-dma: remove restriction on sample rates
This is part of a patch found in Rabeeh Khoury's git tree for the cubox. The kirkwood DMA hardware for ASoC does not impose any restrictions on the sample rates available, so it's silly to impose an artificial set in the DMA code. The restrictions come from the availble clocks to the I2S module, which are already handled in the I2S part of the driver. Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
parent
d8d11ba566
commit
0aa5e47d1f
|
@ -22,8 +22,10 @@
|
|||
#include "kirkwood.h"
|
||||
|
||||
#define KIRKWOOD_RATES \
|
||||
(SNDRV_PCM_RATE_44100 | \
|
||||
SNDRV_PCM_RATE_48000 | SNDRV_PCM_RATE_96000)
|
||||
(SNDRV_PCM_RATE_8000_192000 | \
|
||||
SNDRV_PCM_RATE_CONTINUOUS | \
|
||||
SNDRV_PCM_RATE_KNOT)
|
||||
|
||||
#define KIRKWOOD_FORMATS \
|
||||
(SNDRV_PCM_FMTBIT_S16_LE | \
|
||||
SNDRV_PCM_FMTBIT_S24_LE | \
|
||||
|
@ -43,8 +45,8 @@ static struct snd_pcm_hardware kirkwood_dma_snd_hw = {
|
|||
SNDRV_PCM_INFO_PAUSE),
|
||||
.formats = KIRKWOOD_FORMATS,
|
||||
.rates = KIRKWOOD_RATES,
|
||||
.rate_min = 44100,
|
||||
.rate_max = 96000,
|
||||
.rate_min = 8000,
|
||||
.rate_max = 384000,
|
||||
.channels_min = 1,
|
||||
.channels_max = 2,
|
||||
.buffer_bytes_max = KIRKWOOD_SND_MAX_PERIOD_BYTES * KIRKWOOD_SND_MAX_PERIODS,
|
||||
|
|