ARM: Fix build if CLKDEV_LOOKUP is not configured
mips:allmodconfig fails to build with
drivers/clocksource/timer-sp804.c: In function '__sp804_clocksource_and_sched_clock_init':
drivers/clocksource/timer-sp804.c:88:3: error: implicit declaration of function 'clk_get_sys'
because CLKDEV_LOOKUP is not configured and the driver depends on it.
Fixes: 0b7402dce4
("ARM: 8366/1: move Dual-Timer SP804 driver to drivers/clocksource")
Acked-by: Sudeep Holla <sudeep.holla@arm.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
This commit is contained in:
parent
9ce93bdda7
commit
002af195a8
|
@ -134,7 +134,7 @@ config ARM_GLOBAL_TIMER
|
|||
|
||||
config ARM_TIMER_SP804
|
||||
bool "Support for Dual Timer SP804 module"
|
||||
depends on GENERIC_SCHED_CLOCK
|
||||
depends on GENERIC_SCHED_CLOCK && CLKDEV_LOOKUP
|
||||
select CLKSRC_MMIO
|
||||
select CLKSRC_OF if OF
|
||||
|
||||
|
|