0. Introduction
|
|
|
|
|
|
|
|
The generic cpu cooling(freq clipping) provides registration/unregistration APIs
|
|
|
|
to the caller. The binding of the cooling devices to the trip point is left for
|
|
|
|
the user. The registration APIs returns the cooling device pointer.
|
|
|
|
|
|
|
|
1. cpu cooling APIs
|
|
|
|
|
|
|
|
1.1 cpufreq registration/unregistration APIs
|
|
|
|
1.1.1 struct thermal_cooling_device *cpufreq_cooling_register(
|
|
|
|
struct cpumask *clip_cpus)
|
|
|
|
|
|
|
|
This interface function registers the cpufreq cooling device with the name
|
|
|
|
"thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
|
|
cooling devices.
|
|
|
|
|
|
|
|
clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
|
|
|
|
2015-01-07 02:14:25 +08:00
|
|
|
1.1.2 struct thermal_cooling_device *of_cpufreq_cooling_register(
|
|
|
|
struct device_node *np, const struct cpumask *clip_cpus)
|
|
|
|
|
|
|
|
This interface function registers the cpufreq cooling device with
|
|
|
|
the name "thermal-cpufreq-%x" linking it with a device tree node, in
|
|
|
|
order to bind it via the thermal DT code. This api can support multiple
|
|
|
|
instances of cpufreq cooling devices.
|
|
|
|
|
|
|
|
np: pointer to the cooling device device tree node
|
|
|
|
clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
|
|
|
|
2015-02-27 03:00:29 +08:00
|
|
|
1.1.3 struct thermal_cooling_device *cpufreq_power_cooling_register(
|
|
|
|
const struct cpumask *clip_cpus, u32 capacitance,
|
|
|
|
get_static_t plat_static_func)
|
|
|
|
|
|
|
|
Similar to cpufreq_cooling_register, this function registers a cpufreq
|
|
|
|
cooling device. Using this function, the cooling device will
|
|
|
|
implement the power extensions by using a simple cpu power model. The
|
|
|
|
cpus must have registered their OPPs using the OPP library.
|
|
|
|
|
|
|
|
The additional parameters are needed for the power model (See 2. Power
|
|
|
|
models). "capacitance" is the dynamic power coefficient (See 2.1
|
|
|
|
Dynamic power). "plat_static_func" is a function to calculate the
|
|
|
|
static power consumed by these cpus (See 2.2 Static power).
|
|
|
|
|
|
|
|
1.1.4 struct thermal_cooling_device *of_cpufreq_power_cooling_register(
|
|
|
|
struct device_node *np, const struct cpumask *clip_cpus, u32 capacitance,
|
|
|
|
get_static_t plat_static_func)
|
|
|
|
|
|
|
|
Similar to cpufreq_power_cooling_register, this function register a
|
|
|
|
cpufreq cooling device with power extensions using the device tree
|
|
|
|
information supplied by the np parameter.
|
|
|
|
|
|
|
|
1.1.5 void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
2012-08-16 19:41:40 +08:00
|
|
|
|
|
|
|
This interface function unregisters the "thermal-cpufreq-%x" cooling device.
|
|
|
|
|
|
|
|
cdev: Cooling device pointer which has to be unregistered.
|
2015-02-27 03:00:29 +08:00
|
|
|
|
|
|
|
2. Power models
|
|
|
|
|
|
|
|
The power API registration functions provide a simple power model for
|
|
|
|
CPUs. The current power is calculated as dynamic + (optionally)
|
|
|
|
static power. This power model requires that the operating-points of
|
|
|
|
the CPUs are registered using the kernel's opp library and the
|
|
|
|
`cpufreq_frequency_table` is assigned to the `struct device` of the
|
|
|
|
cpu. If you are using CONFIG_CPUFREQ_DT then the
|
|
|
|
`cpufreq_frequency_table` should already be assigned to the cpu
|
|
|
|
device.
|
|
|
|
|
|
|
|
The `plat_static_func` parameter of `cpufreq_power_cooling_register()`
|
|
|
|
and `of_cpufreq_power_cooling_register()` is optional. If you don't
|
|
|
|
provide it, only dynamic power will be considered.
|
|
|
|
|
|
|
|
2.1 Dynamic power
|
|
|
|
|
|
|
|
The dynamic power consumption of a processor depends on many factors.
|
|
|
|
For a given processor implementation the primary factors are:
|
|
|
|
|
|
|
|
- The time the processor spends running, consuming dynamic power, as
|
|
|
|
compared to the time in idle states where dynamic consumption is
|
|
|
|
negligible. Herein we refer to this as 'utilisation'.
|
|
|
|
- The voltage and frequency levels as a result of DVFS. The DVFS
|
|
|
|
level is a dominant factor governing power consumption.
|
|
|
|
- In running time the 'execution' behaviour (instruction types, memory
|
|
|
|
access patterns and so forth) causes, in most cases, a second order
|
|
|
|
variation. In pathological cases this variation can be significant,
|
|
|
|
but typically it is of a much lesser impact than the factors above.
|
|
|
|
|
|
|
|
A high level dynamic power consumption model may then be represented as:
|
|
|
|
|
|
|
|
Pdyn = f(run) * Voltage^2 * Frequency * Utilisation
|
|
|
|
|
|
|
|
f(run) here represents the described execution behaviour and its
|
|
|
|
result has a units of Watts/Hz/Volt^2 (this often expressed in
|
|
|
|
mW/MHz/uVolt^2)
|
|
|
|
|
|
|
|
The detailed behaviour for f(run) could be modelled on-line. However,
|
|
|
|
in practice, such an on-line model has dependencies on a number of
|
|
|
|
implementation specific processor support and characterisation
|
|
|
|
factors. Therefore, in initial implementation that contribution is
|
|
|
|
represented as a constant coefficient. This is a simplification
|
|
|
|
consistent with the relative contribution to overall power variation.
|
|
|
|
|
|
|
|
In this simplified representation our model becomes:
|
|
|
|
|
|
|
|
Pdyn = Capacitance * Voltage^2 * Frequency * Utilisation
|
|
|
|
|
|
|
|
Where `capacitance` is a constant that represents an indicative
|
|
|
|
running time dynamic power coefficient in fundamental units of
|
|
|
|
mW/MHz/uVolt^2. Typical values for mobile CPUs might lie in range
|
|
|
|
from 100 to 500. For reference, the approximate values for the SoC in
|
|
|
|
ARM's Juno Development Platform are 530 for the Cortex-A57 cluster and
|
|
|
|
140 for the Cortex-A53 cluster.
|
|
|
|
|
|
|
|
|
|
|
|
2.2 Static power
|
|
|
|
|
|
|
|
Static leakage power consumption depends on a number of factors. For a
|
|
|
|
given circuit implementation the primary factors are:
|
|
|
|
|
|
|
|
- Time the circuit spends in each 'power state'
|
|
|
|
- Temperature
|
|
|
|
- Operating voltage
|
|
|
|
- Process grade
|
|
|
|
|
|
|
|
The time the circuit spends in each 'power state' for a given
|
|
|
|
evaluation period at first order means OFF or ON. However,
|
|
|
|
'retention' states can also be supported that reduce power during
|
|
|
|
inactive periods without loss of context.
|
|
|
|
|
|
|
|
Note: The visibility of state entries to the OS can vary, according to
|
|
|
|
platform specifics, and this can then impact the accuracy of a model
|
|
|
|
based on OS state information alone. It might be possible in some
|
|
|
|
cases to extract more accurate information from system resources.
|
|
|
|
|
|
|
|
The temperature, operating voltage and process 'grade' (slow to fast)
|
|
|
|
of the circuit are all significant factors in static leakage power
|
|
|
|
consumption. All of these have complex relationships to static power.
|
|
|
|
|
|
|
|
Circuit implementation specific factors include the chosen silicon
|
|
|
|
process as well as the type, number and size of transistors in both
|
|
|
|
the logic gates and any RAM elements included.
|
|
|
|
|
|
|
|
The static power consumption modelling must take into account the
|
|
|
|
power managed regions that are implemented. Taking the example of an
|
|
|
|
ARM processor cluster, the modelling would take into account whether
|
|
|
|
each CPU can be powered OFF separately or if only a single power
|
|
|
|
region is implemented for the complete cluster.
|
|
|
|
|
|
|
|
In one view, there are others, a static power consumption model can
|
|
|
|
then start from a set of reference values for each power managed
|
|
|
|
region (e.g. CPU, Cluster/L2) in each state (e.g. ON, OFF) at an
|
|
|
|
arbitrary process grade, voltage and temperature point. These values
|
|
|
|
are then scaled for all of the following: the time in each state, the
|
|
|
|
process grade, the current temperature and the operating voltage.
|
|
|
|
However, since both implementation specific and complex relationships
|
|
|
|
dominate the estimate, the appropriate interface to the model from the
|
|
|
|
cpu cooling device is to provide a function callback that calculates
|
|
|
|
the static power in this platform. When registering the cpu cooling
|
|
|
|
device pass a function pointer that follows the `get_static_t`
|
|
|
|
prototype:
|
|
|
|
|
|
|
|
int plat_get_static(cpumask_t *cpumask, int interval,
|
|
|
|
unsigned long voltage, u32 &power);
|
|
|
|
|
|
|
|
`cpumask` is the cpumask of the cpus involved in the calculation.
|
|
|
|
`voltage` is the voltage at which they are operating. The function
|
|
|
|
should calculate the average static power for the last `interval`
|
|
|
|
milliseconds. It returns 0 on success, -E* on error. If it
|
|
|
|
succeeds, it should store the static power in `power`. Reading the
|
|
|
|
temperature of the cpus described by `cpumask` is left for
|
|
|
|
plat_get_static() to do as the platform knows best which thermal
|
|
|
|
sensor is closest to the cpu.
|
|
|
|
|
|
|
|
If `plat_static_func` is NULL, static power is considered to be
|
|
|
|
negligible for this platform and only dynamic power is considered.
|
|
|
|
|
|
|
|
The platform specific callback can then use any combination of tables
|
|
|
|
and/or equations to permute the estimated value. Process grade
|
|
|
|
information is not passed to the model since access to such data, from
|
|
|
|
on-chip measurement capability or manufacture time data, is platform
|
|
|
|
specific.
|
|
|
|
|
|
|
|
Note: the significance of static power for CPUs in comparison to
|
|
|
|
dynamic power is highly dependent on implementation. Given the
|
|
|
|
potential complexity in implementation, the importance and accuracy of
|
|
|
|
its inclusion when using cpu cooling devices should be assessed on a
|
|
|
|
case by case basis.
|
|
|
|
|