* Shared support code for AMD K8 northbridges and derivates.
|
|
* Copyright 2006 Andi Kleen, SUSE Labs. Subject to GPLv2.
|
|
*/
|
|
|
|
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
|
|
|
#include <linux/types.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/init.h>
|
|
#include <linux/errno.h>
|
|
#include <linux/export.h>
|
|
#include <linux/spinlock.h>
|
|
#include <asm/amd_nb.h>
|
|
|
|
#define PCI_DEVICE_ID_AMD_17H_ROOT 0x1450
|
|
#define PCI_DEVICE_ID_AMD_17H_DF_F3 0x1463
|
|
#define PCI_DEVICE_ID_AMD_17H_DF_F4 0x1464
|
|
|
|
/* Protect the PCI config register pairs used for SMN and DF indirect access. */
|
|
static DEFINE_MUTEX(smn_mutex);
|
|
|
|
static u32 *flush_words;
|
|
|
|
static const struct pci_device_id amd_root_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_ROOT) },
|
|
{}
|
|
};
|
|
|
|
const struct pci_device_id amd_nb_misc_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_K8_NB_MISC) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_10H_NB_MISC) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M10H_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M30H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F3) },
|
|
{}
|
|
};
|
|
EXPORT_SYMBOL_GPL(amd_nb_misc_ids);
|
|
|
|
static const struct pci_device_id amd_nb_link_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M30H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F4) },
|
|
{}
|
|
};
|
|
|
|
const struct amd_nb_bus_dev_range amd_nb_bus_dev_ranges[] __initconst = {
|
|
{ 0x00, 0x18, 0x20 },
|
|
{ 0xff, 0x00, 0x20 },
|
|
{ 0xfe, 0x00, 0x20 },
|
|
{ }
|
|
};
|
|
|
|
static struct amd_northbridge_info amd_northbridges;
|
|
|
|
u16 amd_nb_num(void)
|
|
{
|
|
return amd_northbridges.num;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_nb_num);
|
|
|
|
bool amd_nb_has_feature(unsigned int feature)
|
|
{
|
|
return ((amd_northbridges.flags & feature) == feature);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_nb_has_feature);
|
|
|
|
struct amd_northbridge *node_to_amd_nb(int node)
|
|
{
|
|
return (node < amd_northbridges.num) ? &amd_northbridges.nb[node] : NULL;
|
|
}
|
|
EXPORT_SYMBOL_GPL(node_to_amd_nb);
|
|
|
|
static struct pci_dev *next_northbridge(struct pci_dev *dev,
|
|
const struct pci_device_id *ids)
|
|
{
|
|
do {
|
|
dev = pci_get_device(PCI_ANY_ID, PCI_ANY_ID, dev);
|
|
if (!dev)
|
|
break;
|
|
} while (!pci_match_id(ids, dev));
|
|
return dev;
|
|
}
|
|
|
|
static int __amd_smn_rw(u16 node, u32 address, u32 *value, bool write)
|
|
{
|
|
struct pci_dev *root;
|
|
int err = -ENODEV;
|
|
|
|
if (node >= amd_northbridges.num)
|
|
goto out;
|
|
|
|
root = node_to_amd_nb(node)->root;
|
|
if (!root)
|
|
goto out;
|
|
|
|
mutex_lock(&smn_mutex);
|
|
|
|
err = pci_write_config_dword(root, 0x60, address);
|
|
if (err) {
|
|
pr_warn("Error programming SMN address 0x%x.\n", address);
|
|
goto out_unlock;
|
|
}
|
|
|
|
err = (write ? pci_write_config_dword(root, 0x64, *value)
|
|
: pci_read_config_dword(root, 0x64, value));
|
|
if (err)
|
|
pr_warn("Error %s SMN address 0x%x.\n",
|
|
(write ? "writing to" : "reading from"), address);
|
|
|
|
out_unlock:
|
|
mutex_unlock(&smn_mutex);
|
|
|
|
out:
|
|
return err;
|
|
}
|
|
|
|
int amd_smn_read(u16 node, u32 address, u32 *value)
|
|
{
|
|
return __amd_smn_rw(node, address, value, false);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_smn_read);
|
|
|
|
int amd_smn_write(u16 node, u32 address, u32 value)
|
|
{
|
|
return __amd_smn_rw(node, address, &value, true);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_smn_write);
|
|
|
|
/*
|
|
* Data Fabric Indirect Access uses FICAA/FICAD.
|
|
*
|
|
* Fabric Indirect Configuration Access Address (FICAA): Constructed based
|
|
* on the device's Instance Id and the PCI function and register offset of
|
|
* the desired register.
|
|
*
|
|
* Fabric Indirect Configuration Access Data (FICAD): There are FICAD LO
|
|
* and FICAD HI registers but so far we only need the LO register.
|
|
*/
|
|
int amd_df_indirect_read(u16 node, u8 func, u16 reg, u8 instance_id, u32 *lo)
|
|
{
|
|
struct pci_dev *F4;
|
|
u32 ficaa;
|
|
int err = -ENODEV;
|
|
|
|
if (node >= amd_northbridges.num)
|
|
goto out;
|
|
|
|
F4 = node_to_amd_nb(node)->link;
|
|
if (!F4)
|
|
goto out;
|
|
|
|
ficaa = 1;
|
|
ficaa |= reg & 0x3FC;
|
|
ficaa |= (func & 0x7) << 11;
|
|
ficaa |= instance_id << 16;
|
|
|
|
mutex_lock(&smn_mutex);
|
|
|
|
err = pci_write_config_dword(F4, 0x5C, ficaa);
|
|
if (err) {
|
|
pr_warn("Error writing DF Indirect FICAA, FICAA=0x%x\n", ficaa);
|
|
goto out_unlock;
|
|
}
|
|
|
|
err = pci_read_config_dword(F4, 0x98, lo);
|
|
if (err)
|
|
pr_warn("Error reading DF Indirect FICAD LO, FICAA=0x%x.\n", ficaa);
|
|
|
|
out_unlock:
|
|
mutex_unlock(&smn_mutex);
|
|
|
|
out:
|
|
return err;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_df_indirect_read);
|
|
|
|
int amd_cache_northbridges(void)
|
|
{
|
|
u16 i = 0;
|
|
struct amd_northbridge *nb;
|
|
struct pci_dev *root, *misc, *link;
|
|
|
|
if (amd_northbridges.num)
|
|
return 0;
|
|
|
|
misc = NULL;
|
|
while ((misc = next_northbridge(misc, amd_nb_misc_ids)) != NULL)
|
|
i++;
|
|
|
|
if (!i)
|
|
return -ENODEV;
|
|
|
|
nb = kcalloc(i, sizeof(struct amd_northbridge), GFP_KERNEL);
|
|
if (!nb)
|
|
return -ENOMEM;
|
|
|
|
amd_northbridges.nb = nb;
|
|
amd_northbridges.num = i;
|
|
|
|
link = misc = root = NULL;
|
|
for (i = 0; i != amd_northbridges.num; i++) {
|
|
node_to_amd_nb(i)->root = root =
|
|
next_northbridge(root, amd_root_ids);
|
|
node_to_amd_nb(i)->misc = misc =
|
|
next_northbridge(misc, amd_nb_misc_ids);
|
|
node_to_amd_nb(i)->link = link =
|
|
next_northbridge(link, amd_nb_link_ids);
|
|
}
|
|
|
|
if (amd_gart_present())
|
|
amd_northbridges.flags |= AMD_NB_GART;
|
|
|
|
/*
|
|
* Check for L3 cache presence.
|
|
*/
|
|
if (!cpuid_edx(0x80000006))
|
|
return 0;
|
|
|
|
/*
|
|
* Some CPU families support L3 Cache Index Disable. There are some
|
|
* limitations because of E382 and E388 on family 0x10.
|
|
*/
|
|
if (boot_cpu_data.x86 == 0x10 &&
|
|
boot_cpu_data.x86_model >= 0x8 &&
|
|
(boot_cpu_data.x86_model > 0x9 ||
|
|
boot_cpu_data.x86_mask >= 0x1))
|
|
amd_northbridges.flags |= AMD_NB_L3_INDEX_DISABLE;
|
|
|
|
if (boot_cpu_data.x86 == 0x15)
|
|
amd_northbridges.flags |= AMD_NB_L3_INDEX_DISABLE;
|
|
|
|
/* L3 cache partitioning is supported on family 0x15 */
|
|
if (boot_cpu_data.x86 == 0x15)
|
|
amd_northbridges.flags |= AMD_NB_L3_PARTITIONING;
|
|
|
|
return 0;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_cache_northbridges);
|
|
|
|
/*
|
|
* Ignores subdevice/subvendor but as far as I can figure out
|
|
* they're useless anyways
|
|
*/
|
|
bool __init early_is_amd_nb(u32 device)
|
|
{
|
|
const struct pci_device_id *id;
|
|
u32 vendor = device & 0xffff;
|
|
|
|
device >>= 16;
|
|
for (id = amd_nb_misc_ids; id->vendor; id++)
|
|
if (vendor == id->vendor && device == id->device)
|
|
return true;
|
|
return false;
|
|
}
|
|
|
|
struct resource *amd_get_mmconfig_range(struct resource *res)
|
|
{
|
|
u32 address;
|
|
u64 base, msr;
|
|
unsigned int segn_busn_bits;
|
|
|
|
if (boot_cpu_data.x86_vendor != X86_VENDOR_AMD)
|
|
return NULL;
|
|
|
|
/* assume all cpus from fam10h have mmconfig */
|
|
if (boot_cpu_data.x86 < 0x10)
|
|
return NULL;
|
|
|
|
address = MSR_FAM10H_MMIO_CONF_BASE;
|
|
rdmsrl(address, msr);
|
|
|
|
/* mmconfig is not enabled */
|
|
if (!(msr & FAM10H_MMIO_CONF_ENABLE))
|
|
return NULL;
|
|
|
|
base = msr & (FAM10H_MMIO_CONF_BASE_MASK<<FAM10H_MMIO_CONF_BASE_SHIFT);
|
|
|
|
segn_busn_bits = (msr >> FAM10H_MMIO_CONF_BUSRANGE_SHIFT) &
|
|
FAM10H_MMIO_CONF_BUSRANGE_MASK;
|
|
|
|
res->flags = IORESOURCE_MEM;
|
|
res->start = base;
|
|
res->end = base + (1ULL<<(segn_busn_bits + 20)) - 1;
|
|
return res;
|
|
}
|
|
|
|
int amd_get_subcaches(int cpu)
|
|
{
|
|
struct pci_dev *link = node_to_amd_nb(amd_get_nb_id(cpu))->link;
|
|
unsigned int mask;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_L3_PARTITIONING))
|
|
return 0;
|
|
|
|
pci_read_config_dword(link, 0x1d4, &mask);
|
|
|
|
return (mask >> (4 * cpu_data(cpu).cpu_core_id)) & 0xf;
|
|
}
|
|
|
|
int amd_set_subcaches(int cpu, unsigned long mask)
|
|
{
|
|
static unsigned int reset, ban;
|
|
struct amd_northbridge *nb = node_to_amd_nb(amd_get_nb_id(cpu));
|
|
unsigned int reg;
|
|
int cuid;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_L3_PARTITIONING) || mask > 0xf)
|
|
return -EINVAL;
|
|
|
|
/* if necessary, collect reset state of L3 partitioning and BAN mode */
|
|
if (reset == 0) {
|
|
pci_read_config_dword(nb->link, 0x1d4, &reset);
|
|
pci_read_config_dword(nb->misc, 0x1b8, &ban);
|
|
ban &= 0x180000;
|
|
}
|
|
|
|
/* deactivate BAN mode if any subcaches are to be disabled */
|
|
if (mask != 0xf) {
|
|
pci_read_config_dword(nb->misc, 0x1b8, ®);
|
|
pci_write_config_dword(nb->misc, 0x1b8, reg & ~0x180000);
|
|
}
|
|
|
|
cuid = cpu_data(cpu).cpu_core_id;
|
|
mask <<= 4 * cuid;
|
|
mask |= (0xf ^ (1 << cuid)) << 26;
|
|
|
|
pci_write_config_dword(nb->link, 0x1d4, mask);
|
|
|
|
/* reset BAN mode if L3 partitioning returned to reset state */
|
|
pci_read_config_dword(nb->link, 0x1d4, ®);
|
|
if (reg == reset) {
|
|
pci_read_config_dword(nb->misc, 0x1b8, ®);
|
|
reg &= ~0x180000;
|
|
pci_write_config_dword(nb->misc, 0x1b8, reg | ban);
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void amd_cache_gart(void)
|
|
{
|
|
u16 i;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_GART))
|
|
return;
|
|
|
|
flush_words = kmalloc_array(amd_northbridges.num, sizeof(u32), GFP_KERNEL);
|
|
if (!flush_words) {
|
|
amd_northbridges.flags &= ~AMD_NB_GART;
|
|
pr_notice("Cannot initialize GART flush words, GART support disabled\n");
|
|
return;
|
|
}
|
|
|
|
for (i = 0; i != amd_northbridges.num; i++)
|
|
pci_read_config_dword(node_to_amd_nb(i)->misc, 0x9c, &flush_words[i]);
|
|
}
|
|
|
|
void amd_flush_garts(void)
|
|
{
|
|
int flushed, i;
|
|
unsigned long flags;
|
|
static DEFINE_SPINLOCK(gart_lock);
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_GART))
|
|
return;
|
|
|
|
/*
|
|
* Avoid races between AGP and IOMMU. In theory it's not needed
|
|
* but I'm not sure if the hardware won't lose flush requests
|
|
* when another is pending. This whole thing is so expensive anyways
|
|
* that it doesn't matter to serialize more. -AK
|
|
*/
|
|
spin_lock_irqsave(&gart_lock, flags);
|
|
flushed = 0;
|
|
for (i = 0; i < amd_northbridges.num; i++) {
|
|
pci_write_config_dword(node_to_amd_nb(i)->misc, 0x9c,
|
|
flush_words[i] | 1);
|
|
flushed++;
|
|
}
|
|
for (i = 0; i < amd_northbridges.num; i++) {
|
|
u32 w;
|
|
/* Make sure the hardware actually executed the flush*/
|
|
for (;;) {
|
|
pci_read_config_dword(node_to_amd_nb(i)->misc,
|
|
0x9c, &w);
|
|
if (!(w & 1))
|
|
break;
|
|
cpu_relax();
|
|
}
|
|
}
|
|
spin_unlock_irqrestore(&gart_lock, flags);
|
|
if (!flushed)
|
|
pr_notice("nothing to flush?\n");
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_flush_garts);
|
|
|
|
static __init int init_amd_nbs(void)
|
|
{
|
|
amd_cache_northbridges();
|
|
amd_cache_gart();
|
|
|
|
return 0;
|
|
}
|
|
|
|
/* This has to go after the PCI subsystem */
|
|