The powerpc 64-bit __copy_tofrom_user() function uses shifts to handle
unaligned invocations. However, these shifts were designed for
big-endian systems: On little-endian systems, they must shift in the
opposite direction.
This commit relies on the C preprocessor to insert the correct shifts
into the assembly code.
[ This is a rare but nasty LE issue. Most of the time we use the POWER7
optimised __copy_tofrom_user_power7 loop, but when it hits an exception
we fall back to the base __copy_tofrom_user loop. - Anton ]
Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com>
Signed-off-by: Anton Blanchard <anton@samba.org>
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>