What: /sys/bus/counter/devices/counterX/signalY/index_polarity
|
|
KernelVersion: 5.2
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
Active level of index input Signal Y; irrelevant in
|
|
non-synchronous load mode.
|
|
|
|
What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
|
|
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
|
|
KernelVersion: 5.2
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
Discrete set of available values for the respective Signal Y
|
|
configuration are listed in this file.
|
|
|
|
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
|
|
KernelVersion: 5.2
|
|
Contact: linux-iio@vger.kernel.org
|
|
Description:
|
|
Configure the counter associated with Signal Y for
|
|
non-synchronous or synchronous load mode. Synchronous load mode
|
|
cannot be selected in non-quadrature (Pulse-Direction) clock
|
|
mode.
|
|
|
|
non-synchronous:
|
|
A logic low level is the active level at this index
|
|
input. The index function (as enabled via preset_enable)
|
|
is performed directly on the active level of the index
|
|
input.
|
|
|
|
synchronous:
|
|
Intended for interfacing with encoder Index output in
|
|
quadrature clock mode. The active level is configured
|
|
via index_polarity. The index function (as enabled via
|
|
preset_enable) is performed synchronously with the
|
|