Similarly to PLLs/FLLs some modern CODECs provide selectable system clock
sources. When the clock is the clock for a DAI we do not usually need to
identify which clock is being configured so can use clk_id for the source
clock but with CODEC wide system clocks we will need to specify both the
clock being configured and the source.
Add a source argument to the CODEC driver set_sysclk() operation to
reflect this. As this operation is not as widely used as the DAI
set_sysclk() operation the change is not very invasive. We probably
ought to go and make the same alternation for DAIs at some point.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>