In a typical read transfer, start completion flag is being set after
read finishes (notice ipd bit 4 being set):
trasnfer poll=0
i2c start
rk3x-i2c fdd40000.i2c: IRQ: state 1, ipd: 10
i2c read
rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 1b
i2c stop
rk3x-i2c fdd40000.i2c: IRQ: state 4, ipd: 33
This causes I2C transfer being aborted in polled mode from a stop completion
handler:
trasnfer poll=1
i2c start
rk3x-i2c fdd40000.i2c: IRQ: state 1, ipd: 10
i2c read
rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 0
rk3x-i2c fdd40000.i2c: IRQ: state 2, ipd: 1b
i2c stop
rk3x-i2c fdd40000.i2c: IRQ: state 4, ipd: 13
i2c stop
rk3x-i2c fdd40000.i2c: unexpected irq in STOP: 0x10
Clearing the START flag after read fixes the issue without any obvious
side effects.
This issue was dicovered on RK3566 when adding support for powering
off the RK817 PMIC.
Signed-off-by: Ondrej Jirman <megous@megous.com>
Reviewed-by: John Keeping <john@metanate.com>
Signed-off-by: Wolfram Sang <wsa@kernel.org>