adcf04c9f8
At least with the Inspired Energy compatible batteries a delay is required after setting the capacity mode bit from amp to watts or the reverse. Setting the bit and then immediately pooling the status register results in an unknown error being returned in the register. Add the delay results in and ok status being return. This was also seen when reading the charge and energy registers where the wrong value was returned for the requested mode. Signed-off-by: Phil Reid <preid@electromag.com.au> Tested-by: Michael Heinemann <committed@heine.so> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk> |
||
---|---|---|
.. | ||
avs | ||
reset | ||
supply | ||
Kconfig | ||
Makefile |