If a driver does not set interrupt triggering type when it calls
request_irq(), it means use the pin as the hardware/firmware has
configured it. There are some drivers doing this. One example is
drivers/input/serio/i8042.c that requests the interrupt like:
error = request_irq(I8042_KBD_IRQ, i8042_interrupt, IRQF_SHARED,
"i8042", i8042_platform_device);
It assumes the interrupt is already properly configured. This is true in
case of interrupts connected to the IO-APIC. However, some Intel
Braswell/Cherryview based machines use a GPIO here instead for the internal
keyboard controller.
This is a problem because even if the pin/interrupt is properly configured,
the irqchip ->irq_set_type() will never be called as the triggering flags
are 0. Because of that we do not have correct interrupt flow handler set
for the interrupt.
Fix this by adding a custom ->irq_startup() that checks if the interrupt
has no triggering type set and in that case read the type directly from the
hardware and install correct flow handler along with the mapping.
Reported-by: Jagadish Krishnamoorthy <jagadish.krishnamoorthy@intel.com>
Reported-by: Freddy Paul <freddy.paul@intel.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>