WMI PCP Start flow should not be handled through:
net_device_ops->ndo_open()->wil_up()->__wil_up()
because it missing mandatory FW parameters (SSID,Channel,IEs, Security...).
Prior to AP starting __wil_up() may be called with iftype set
cfg80211_ops->change_virtual_intf(NL80211_IFTYPE_AP or STATION)
depend on the application hostapd/wpa_supplicant/iw.
there should not be an attempt to start an AP flow,
AP/PCP start flow will be started latter by cfg80211_ops->start_ap().
Signed-off-by: Kirshenbaum Erez <erezk@wilocity.com>
Signed-off-by: Vladimir Kondratiev <qca_vkondrat@qca.qualcomm.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>