HNS3(HiSilicon Network System 3) PMU is RCiEP device in HiSilicon SoC NIC,
supports collection of performance statistics such as bandwidth, latency,
packet rate and interrupt rate.
NIC of each SICL has one PMU device for it. Driver registers each PMU
device to perf, and exports information of supported events, filter mode of
each event, bdf range, hardware clock frequency, identifier and so on via
sysfs.
Each PMU device has its own registers of control, counters and interrupt,
and it supports 8 hardware events, each hardward event has its own
registers for configuration, counters and interrupt.
Filter options contains:
config - select event
port - select physical port of nic
tc - select tc(must be used with port)
func - select PF/VF
queue - select queue of PF/VF(must be used with func)
intr - select interrupt number(must be used with func)
global - select all functions of IO DIE
Signed-off-by: Guangbin Huang <huangguangbin2@huawei.com>
Reviewed-by: John Garry <john.garry@huawei.com>
Reviewed-by: Shaokun Zhang <zhangshaokun@hisilicon.com>
Link: https://lore.kernel.org/r/20220628063419.38514-3-huangguangbin2@huawei.com
Signed-off-by: Will Deacon <will@kernel.org>