OpenCloudOS-Kernel/Documentation/ABI/testing/sysfs-bus-counter-104-quad-8

62 lines
2.3 KiB
Plaintext

What: /sys/bus/counter/devices/counterX/signalY/cable_fault
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Read-only attribute that indicates whether a differential
encoder cable fault (not connected or loose wires) is detected
for the respective channel of Signal Y. Valid attribute values
are boolean. Detection must first be enabled via the
corresponding cable_fault_enable attribute.
What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Whether detection of differential encoder cable faults for the
respective channel of Signal Y is enabled. Valid attribute
values are boolean.
What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
KernelVersion: 5.7
Contact: linux-iio@vger.kernel.org
Description:
Filter clock factor for input Signal Y. This prescaler value
affects the inputs of both quadrature pair signals.
What: /sys/bus/counter/devices/counterX/signalY/index_polarity
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Active level of index input Signal Y; irrelevant in
non-synchronous load mode.
What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Discrete set of available values for the respective Signal Y
configuration are listed in this file.
What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
KernelVersion: 5.2
Contact: linux-iio@vger.kernel.org
Description:
Configure the counter associated with Signal Y for
non-synchronous or synchronous load mode. Synchronous load mode
cannot be selected in non-quadrature (Pulse-Direction) clock
mode.
non-synchronous:
A logic low level is the active level at this index
input. The index function (as enabled via preset_enable)
is performed directly on the active level of the index
input.
synchronous:
Intended for interfacing with encoder Index output in
quadrature clock mode. The active level is configured
via index_polarity. The index function (as enabled via
preset_enable) is performed synchronously with the
quadrature clock on the active level of the index input.