366 lines
9.0 KiB
Plaintext
366 lines
9.0 KiB
Plaintext
* CoreSight Components:
|
|
|
|
CoreSight components are compliant with the ARM CoreSight architecture
|
|
specification and can be connected in various topologies to suit a particular
|
|
SoCs tracing needs. These trace components can generally be classified as
|
|
sinks, links and sources. Trace data produced by one or more sources flows
|
|
through the intermediate links connecting the source to the currently selected
|
|
sink. Each CoreSight component device should use these properties to describe
|
|
its hardware characteristcs.
|
|
|
|
* Required properties for all components *except* non-configurable replicators
|
|
and non-configurable funnels:
|
|
|
|
* compatible: These have to be supplemented with "arm,primecell" as
|
|
drivers are using the AMBA bus interface. Possible values include:
|
|
- Embedded Trace Buffer (version 1.0):
|
|
"arm,coresight-etb10", "arm,primecell";
|
|
|
|
- Trace Port Interface Unit:
|
|
"arm,coresight-tpiu", "arm,primecell";
|
|
|
|
- Trace Memory Controller, used for Embedded Trace Buffer(ETB),
|
|
Embedded Trace FIFO(ETF) and Embedded Trace Router(ETR)
|
|
configuration. The configuration mode (ETB, ETF, ETR) is
|
|
discovered at boot time when the device is probed.
|
|
"arm,coresight-tmc", "arm,primecell";
|
|
|
|
- Trace Programmable Funnel:
|
|
"arm,coresight-dynamic-funnel", "arm,primecell";
|
|
"arm,coresight-funnel", "arm,primecell"; (OBSOLETE. For
|
|
backward compatibility and will be removed)
|
|
|
|
- Embedded Trace Macrocell (version 3.x) and
|
|
Program Flow Trace Macrocell:
|
|
"arm,coresight-etm3x", "arm,primecell";
|
|
|
|
- Embedded Trace Macrocell (version 4.x):
|
|
"arm,coresight-etm4x", "arm,primecell";
|
|
|
|
- Coresight programmable Replicator :
|
|
"arm,coresight-dynamic-replicator", "arm,primecell";
|
|
|
|
- System Trace Macrocell:
|
|
"arm,coresight-stm", "arm,primecell"; [1]
|
|
- Coresight Address Translation Unit (CATU)
|
|
"arm,coresight-catu", "arm,primecell";
|
|
|
|
* reg: physical base address and length of the register
|
|
set(s) of the component.
|
|
|
|
* clocks: the clocks associated to this component.
|
|
|
|
* clock-names: the name of the clocks referenced by the code.
|
|
Since we are using the AMBA framework, the name of the clock
|
|
providing the interconnect should be "apb_pclk", and some
|
|
coresight blocks also have an additional clock "atclk", which
|
|
clocks the core of that coresight component. The latter clock
|
|
is optional.
|
|
|
|
* port or ports: see "Graph bindings for Coresight" below.
|
|
|
|
* Additional required property for Embedded Trace Macrocell (version 3.x and
|
|
version 4.x):
|
|
* cpu: the cpu phandle this ETM/PTM is affined to. Do not
|
|
assume it to default to CPU0 if omitted.
|
|
|
|
* Additional required properties for System Trace Macrocells (STM):
|
|
* reg: along with the physical base address and length of the register
|
|
set as described above, another entry is required to describe the
|
|
mapping of the extended stimulus port area.
|
|
|
|
* reg-names: the only acceptable values are "stm-base" and
|
|
"stm-stimulus-base", each corresponding to the areas defined in "reg".
|
|
|
|
* Required properties for devices that don't show up on the AMBA bus, such as
|
|
non-configurable replicators and non-configurable funnels:
|
|
|
|
* compatible: Currently supported value is (note the absence of the
|
|
AMBA markee):
|
|
- Coresight Non-configurable Replicator:
|
|
"arm,coresight-static-replicator";
|
|
"arm,coresight-replicator"; (OBSOLETE. For backward
|
|
compatibility and will be removed)
|
|
|
|
- Coresight Non-configurable Funnel:
|
|
"arm,coresight-static-funnel";
|
|
|
|
* port or ports: see "Graph bindings for Coresight" below.
|
|
|
|
* Optional properties for ETM/PTMs:
|
|
|
|
* arm,cp14: must be present if the system accesses ETM/PTM management
|
|
registers via co-processor 14.
|
|
|
|
* Optional property for TMC:
|
|
|
|
* arm,buffer-size: size of contiguous buffer space for TMC ETR
|
|
(embedded trace router). This property is obsolete. The buffer size
|
|
can be configured dynamically via buffer_size property in sysfs.
|
|
|
|
* arm,scatter-gather: boolean. Indicates that the TMC-ETR can safely
|
|
use the SG mode on this system.
|
|
|
|
* Optional property for CATU :
|
|
* interrupts : Exactly one SPI may be listed for reporting the address
|
|
error
|
|
|
|
Graph bindings for Coresight
|
|
-------------------------------
|
|
|
|
Coresight components are interconnected to create a data path for the flow of
|
|
trace data generated from the "sources" to their collection points "sink".
|
|
Each coresight component must describe the "input" and "output" connections.
|
|
The connections must be described via generic DT graph bindings as described
|
|
by the "bindings/graph.txt", where each "port" along with an "endpoint"
|
|
component represents a hardware port and the connection.
|
|
|
|
* All output ports must be listed inside a child node named "out-ports"
|
|
* All input ports must be listed inside a child node named "in-ports".
|
|
* Port address must match the hardware port number.
|
|
|
|
Example:
|
|
|
|
1. Sinks
|
|
etb@20010000 {
|
|
compatible = "arm,coresight-etb10", "arm,primecell";
|
|
reg = <0 0x20010000 0 0x1000>;
|
|
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
in-ports {
|
|
port {
|
|
etb_in_port: endpoint@0 {
|
|
remote-endpoint = <&replicator_out_port0>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
tpiu@20030000 {
|
|
compatible = "arm,coresight-tpiu", "arm,primecell";
|
|
reg = <0 0x20030000 0 0x1000>;
|
|
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
in-ports {
|
|
port {
|
|
tpiu_in_port: endpoint@0 {
|
|
remote-endpoint = <&replicator_out_port1>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
etr@20070000 {
|
|
compatible = "arm,coresight-tmc", "arm,primecell";
|
|
reg = <0 0x20070000 0 0x1000>;
|
|
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
in-ports {
|
|
port {
|
|
etr_in_port: endpoint {
|
|
remote-endpoint = <&replicator2_out_port0>;
|
|
};
|
|
};
|
|
};
|
|
|
|
out-ports {
|
|
port {
|
|
etr_out_port: endpoint {
|
|
remote-endpoint = <&catu_in_port>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
2. Links
|
|
replicator {
|
|
/* non-configurable replicators don't show up on the
|
|
* AMBA bus. As such no need to add "arm,primecell".
|
|
*/
|
|
compatible = "arm,coresight-static-replicator";
|
|
|
|
out-ports {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
/* replicator output ports */
|
|
port@0 {
|
|
reg = <0>;
|
|
replicator_out_port0: endpoint {
|
|
remote-endpoint = <&etb_in_port>;
|
|
};
|
|
};
|
|
|
|
port@1 {
|
|
reg = <1>;
|
|
replicator_out_port1: endpoint {
|
|
remote-endpoint = <&tpiu_in_port>;
|
|
};
|
|
};
|
|
};
|
|
|
|
in-ports {
|
|
port {
|
|
replicator_in_port0: endpoint {
|
|
remote-endpoint = <&funnel_out_port0>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
funnel {
|
|
/*
|
|
* non-configurable funnel don't show up on the AMBA
|
|
* bus. As such no need to add "arm,primecell".
|
|
*/
|
|
compatible = "arm,coresight-static-funnel";
|
|
clocks = <&crg_ctrl HI3660_PCLK>;
|
|
clock-names = "apb_pclk";
|
|
|
|
out-ports {
|
|
port {
|
|
combo_funnel_out: endpoint {
|
|
remote-endpoint = <&top_funnel_in>;
|
|
};
|
|
};
|
|
};
|
|
|
|
in-ports {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
port@0 {
|
|
reg = <0>;
|
|
combo_funnel_in0: endpoint {
|
|
remote-endpoint = <&cluster0_etf_out>;
|
|
};
|
|
};
|
|
|
|
port@1 {
|
|
reg = <1>;
|
|
combo_funnel_in1: endpoint {
|
|
remote-endpoint = <&cluster1_etf_out>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
funnel@20040000 {
|
|
compatible = "arm,coresight-dynamic-funnel", "arm,primecell";
|
|
reg = <0 0x20040000 0 0x1000>;
|
|
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
out-ports {
|
|
port {
|
|
funnel_out_port0: endpoint {
|
|
remote-endpoint =
|
|
<&replicator_in_port0>;
|
|
};
|
|
};
|
|
};
|
|
|
|
in-ports {
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
|
|
port@0 {
|
|
reg = <0>;
|
|
funnel_in_port0: endpoint {
|
|
remote-endpoint = <&ptm0_out_port>;
|
|
};
|
|
};
|
|
|
|
port@1 {
|
|
reg = <1>;
|
|
funnel_in_port1: endpoint {
|
|
remote-endpoint = <&ptm1_out_port>;
|
|
};
|
|
};
|
|
|
|
port@2 {
|
|
reg = <2>;
|
|
funnel_in_port2: endpoint {
|
|
remote-endpoint = <&etm0_out_port>;
|
|
};
|
|
};
|
|
|
|
};
|
|
};
|
|
|
|
3. Sources
|
|
ptm@2201c000 {
|
|
compatible = "arm,coresight-etm3x", "arm,primecell";
|
|
reg = <0 0x2201c000 0 0x1000>;
|
|
|
|
cpu = <&cpu0>;
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
out-ports {
|
|
port {
|
|
ptm0_out_port: endpoint {
|
|
remote-endpoint = <&funnel_in_port0>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
ptm@2201d000 {
|
|
compatible = "arm,coresight-etm3x", "arm,primecell";
|
|
reg = <0 0x2201d000 0 0x1000>;
|
|
|
|
cpu = <&cpu1>;
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
out-ports {
|
|
port {
|
|
ptm1_out_port: endpoint {
|
|
remote-endpoint = <&funnel_in_port1>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
4. STM
|
|
stm@20100000 {
|
|
compatible = "arm,coresight-stm", "arm,primecell";
|
|
reg = <0 0x20100000 0 0x1000>,
|
|
<0 0x28000000 0 0x180000>;
|
|
reg-names = "stm-base", "stm-stimulus-base";
|
|
|
|
clocks = <&soc_smc50mhz>;
|
|
clock-names = "apb_pclk";
|
|
out-ports {
|
|
port {
|
|
stm_out_port: endpoint {
|
|
remote-endpoint = <&main_funnel_in_port2>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
5. CATU
|
|
|
|
catu@207e0000 {
|
|
compatible = "arm,coresight-catu", "arm,primecell";
|
|
reg = <0 0x207e0000 0 0x1000>;
|
|
|
|
clocks = <&oscclk6a>;
|
|
clock-names = "apb_pclk";
|
|
|
|
interrupts = <GIC_SPI 4 IRQ_TYPE_LEVEL_HIGH>;
|
|
in-ports {
|
|
port {
|
|
catu_in_port: endpoint {
|
|
remote-endpoint = <&etr_out_port>;
|
|
};
|
|
};
|
|
};
|
|
};
|
|
|
|
[1]. There is currently two version of STM: STM32 and STM500. Both
|
|
have the same HW interface and as such don't need an explicit binding name.
|