5ac447d268
Three small fixes for recently merged code: - remove a spurious WARN_ON when a PCI device has no of_node, it's allowed in some circumstances for there to be no of_node. - fix the offset for store EOI MMIOs in the XIVE interrupt controller. - fix non-const WARN_ONs which were becoming BUGs due to them losing BUGFLAG_WARNING in a recent cleanup patch. Thanks to: Alexey Kardashevskiy, Alistair Popple, Benjamin Herrenschmidt. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1 iQIcBAABAgAGBQJZQ7XeAAoJEFHr6jzI4aWA2bgP/R++c9YehNdDKbZyLqumY+6q 7ns8NoxgEW/Gc8JuSTE4MW51q2HimBJu6ntyHfMUwgpGQpGzOGDn6g8OxVfjOySa kFc7cytgOOhEpTHENDZ3xxZtcSd9iafyX9ga/0dz6UycfEHcZayiXDRuXffRzJwa RNqbwDxOtkgn6w4bW02SRlfDSTra+zQZQd6NsPXSJJgF+tb3MflMj1A9WoJp/mj/ tXc9fpKQsZkIG/AvAHziizHqeAKJxUrmoVb8qy1SYTKVUDZoxTYgiO1G1nebZX/s Zzsdd/fcHcd0DIEJkjf2V3cegmIGTLzw7mUOodU7IF3mZ1LPgCMVF5lTTZzjcXDQ d1gugVojHnGr7KB3lNNijyHxsmHG7LdTQmRHcyZ2L8KYpa3/+Ca3ZuFnTwjvgRNx dJEFX5JdAhCrkg1B73rvcjKCFg0ysVIrkdf27SaameaQdQQuZU4+5+s1LB2EqJQr II3+pnZr/RF3OWu4yJE5KAHX5ZBQQ+unzVPpW4pqvwYMoVKhO7dhCPPISeRCtzJE +po5Ys4ncheSRhwf5dQhf+H04kXmL6ekpl1GJOBB3BskJcsIr8hiLp3/mF238et1 80o6yTAJLADKUIl75ISiePz+KFZNamgke1/XWZolfHYZ9dNRF0c//E0qvpopz8jE F90hxEAtJ9ws/VUlo40Q =Mnxp -----END PGP SIGNATURE----- Merge tag 'powerpc-4.12-6' of git://git.kernel.org/pub/scm/linux/kernel/git/powerpc/linux Pull powerpc fixes from Michael Ellerman: "Three small fixes for recently merged code: - remove a spurious WARN_ON when a PCI device has no of_node, it's allowed in some circumstances for there to be no of_node. - fix the offset for store EOI MMIOs in the XIVE interrupt controller. - fix non-const WARN_ONs which were becoming BUGs due to them losing BUGFLAG_WARNING in a recent cleanup patch. Thanks to: Alexey Kardashevskiy, Alistair Popple, Benjamin Herrenschmidt" * tag 'powerpc-4.12-6' of git://git.kernel.org/pub/scm/linux/kernel/git/powerpc/linux: powerpc/debug: Add missing warn flag to WARN_ON's non-builtin path powerpc/xive: Fix offset for store EOI MMIOs powerpc/npu-dma: Remove spurious WARN_ON when a PCI device has no of_node |
||
---|---|---|
Documentation | ||
arch | ||
block | ||
certs | ||
crypto | ||
drivers | ||
firmware | ||
fs | ||
include | ||
init | ||
ipc | ||
kernel | ||
lib | ||
mm | ||
net | ||
samples | ||
scripts | ||
security | ||
sound | ||
tools | ||
usr | ||
virt | ||
.cocciconfig | ||
.get_maintainer.ignore | ||
.gitattributes | ||
.gitignore | ||
.mailmap | ||
COPYING | ||
CREDITS | ||
Kbuild | ||
Kconfig | ||
MAINTAINERS | ||
Makefile | ||
README |
README
Linux kernel ============ This file was moved to Documentation/admin-guide/README.rst Please notice that there are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. See Documentation/00-INDEX for a list of what is contained in each file. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.