Do not change the codec defaults for the following registers:
0x40, 0x41: Line output gains, do not use amplification
0x42: LOM/LOP Voltage hold, and selection
0x44: LOM inversion control
It has been found, that the values configured to these registers
can cause amplification, which can make the output of DAC33
distorted.
The codec reset values are considered safe in all environmnts.
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>