df1d80aee9
For devices from the SigmaDelta family we need to keep CS low when doing a conversion, since the device will use the MISO line as a interrupt to indicate that the conversion is complete. This is why the driver locks the SPI bus and when the SPI bus is locked keeps as long as a conversion is going on. The current implementation gets one small detail wrong though. CS is only de-asserted after the SPI bus is unlocked. This means it is possible for a different SPI device on the same bus to send a message which would be wrongfully be addressed to the SigmaDelta device as well. Make sure that the last SPI transfer that is done while holding the SPI bus lock de-asserts the CS signal. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Signed-off-by: Alexandru Ardelean <Alexandru.Ardelean@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> |
||
---|---|---|
.. | ||
ad_sigma_delta.h | ||
stm32-dfsdm-adc.h |