An attribute should only be exporting one value as recommended in
Documentation/filesystems/sysfs.rst. Implement CMB attributes this way.
The old attribute will remain for backward compatibility.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Appending sysfs files to the controller kobject is a bit clunky and
becomes a maintenance problem as more attributes are added. The
attribute group infrastructure handles this better, so use that.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We cannot detect a (perhaps buggy) controller that is sending us
a completion for a request that was already completed (for example
sending a completion twice), this phenomenon was seen in the wild
a few times.
So to protect against this, we use the upper 4 msbits of the nvme sqe
command_id to use as a 4-bit generation counter and verify it matches
the existing request generation that is incrementing on every execution.
The 16-bit command_id structure now is constructed by:
| xxxx | xxxxxxxxxxxx |
gen request tag
This means that we are giving up some possible queue depth as 12 bits
allow for a maximum queue depth of 4095 instead of 65536, however we
never create such long queues anyways so no real harm done.
Suggested-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Acked-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Tested-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We already validate it when receiving the c2hdata pdu header
and this is not changing so this is a redundant check.
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We are going to use the upper 4-bits of the command_id for a generation
counter, so enforce the new queue depth upper limit. As we enforce
both min and max queue depth, use param_set_uint_minmax istead of
open coding it.
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Lightnvm supports the OCSSD 1.x and 2.0 specs which were early attempts
to produce Open Channel SSDs and never made it into the NVMe spec
proper. They have since been superceeded by NVMe enhancements such
as ZNS support. Remove the support per the deprecation schedule.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Link: https://lore.kernel.org/r/20210812132308.38486-1-hch@lst.de
Reviewed-by: Matias Bjørling <mb@lightnvm.io>
Reviewed-by: Javier González <javier@javigon.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Just check inode_unhashed on the whole device bdev inode instead,
and provide a helper to check for that information.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Link: https://lore.kernel.org/r/20210809064028.1198327-9-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Use the nvme-internal NVME_NSHEAD_DISK_LIVE flag instead of abusing
the block layer state.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Link: https://lore.kernel.org/r/20210809064028.1198327-5-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Early probe failure never reaches nvme_ns_remove, so GENHD_FL_UP must
be set at this point. Remove the check.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Link: https://lore.kernel.org/r/20210809064028.1198327-4-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
.. and rename the function to disk_update_readahead. This is in
preparation for moving the BDI from the request_queue to the gendisk.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Jan Kara <jack@suse.cz>
Reviewed-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Link: https://lore.kernel.org/r/20210809141744.1203023-3-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
-----BEGIN PGP SIGNATURE-----
iQJEBAABCAAuFiEEwPw5LcreJtl1+l5K99NY+ylx4KYFAmD8NkkQHGF4Ym9lQGtl
cm5lbC5kawAKCRD301j7KXHgprfxEACKUWYgb6OSc121lltJTFTZ8LDLxKLn4dNt
5SREbhPdUXKZ64fTo6dKx3ZQ0SZkY+90aTOQQClSNps3/hsIuGsXcLnaPBgEET21
GgCaJfT1B4i/NCjguwboprGPQjETLUTXHri8e/5C8OBgFSL4Q62Cvsl2l5U1V9rP
v4O21TazHNVWnV60uJ4FZvQ56zU/mlvU77eWnfa1MJQaupl1atUwhDNTidDNVMYN
v69nJqxgYIo5pvNVkMwHxWcp6Ckkwj5GaxptcJ5EPBU69sImBCZ8fpYVrrS3NzTL
82Xf/HFVmJdegRqk0fctWGOfkorBl1ah/+PhL69In/6y6lHOs9y9+lTHoWq/+z8z
cPj/Ru6440Gf5D81rzbJRmCKNE4k2ToYnvRTHj2kUSRoAxDih0S3axZMF7m9eEnQ
DNOG29bsskJhYPx/0HxffCTAsKf2iPlMCRQFTqR296F5Hbg1eMo9rDSXY5JCtlNU
jOKKPmBM5fZWn19QIvjlxICsS3TRRun4jpcpbQZKoY1ItuN9x5ANmlr54K7T4gD3
RYXZ51dPDaEFQGO0bwKlRj6w45F7wZb7HBNufXl2WsuSbM88sGEXUkYlBQ55xjJK
Y8+amkzA2XUorQIrfsegzkCw67CuCB7Pg2IQWoiyFLagBTfoX8QJPslRRwUFiBav
QZi3lITl5Q==
=uzwV
-----END PGP SIGNATURE-----
Merge tag 'block-5.14-2021-07-24' of git://git.kernel.dk/linux-block
Pull block fixes from Jens Axboe:
- NVMe pull request (Christoph):
- tracing fix (Keith Busch)
- fix multipath head refcounting (Hannes Reinecke)
- Write Zeroes vs PI fix (me)
- drop a bogus WARN_ON (Zhihao Cheng)
- Increase max blk-cgroup policy size, now that mq-deadline
uses it too (Oleksandr)
* tag 'block-5.14-2021-07-24' of git://git.kernel.dk/linux-block:
nvme: set the PRACT bit when using Write Zeroes with T10 PI
nvme: fix nvme_setup_command metadata trace event
nvme: fix refcounting imbalance when all paths are down
nvme-pci: don't WARN_ON in nvme_reset_work if ctrl.state is not RESETTING
block: increase BLKCG_MAX_POLS
When using Write Zeroes on a namespace that has protection
information enabled they behavior without the PRACT bit
counter-intuitive and will generally lead to validation failures
when reading the written blocks. Fix this by always setting the
PRACT bit that generates matching PI data on the fly.
Fixes: 6e02318eae ("nvme: add support for the Write Zeroes command")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
The metadata address is set after the trace event, so the trace is not
capturing anything useful. Rather than logging the memory address, it's
useful to know if the command carries a metadata payload, so change the
trace event to log that true/false state instead.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When the last path to a ns_head drops the current code
removes the ns_head from the subsystem list, but will only
delete the disk itself if the last reference to the ns_head
drops. This is causing an refcounting imbalance eg when
applications have a reference to the disk, as then they'll
never get notified that the disk is in fact dead.
This patch moves the call 'del_gendisk' into nvme_mpath_check_last_path(),
ensuring that the disk can be properly removed and applications get the
appropriate notifications.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
-----BEGIN PGP SIGNATURE-----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=Zeni
-----END PGP SIGNATURE-----
Merge tag 'block-5.14-2021-07-16' of git://git.kernel.dk/linux-block
Pull block fixes from Jens Axboe:
- NVMe fixes via Christoph:
- fix various races in nvme-pci when shutting down just after
probing (Casey Chen)
- fix a net_device leak in nvme-tcp (Prabhakar Kushwaha)
- Fix regression in xen-blkfront by cleaning up the removal state
machine (Christoph)
- Fix tag_set and queue cleanup ordering regression in nbd (Wang)
- Fix tag_set and queue cleanup ordering regression in pd (Guoqing)
* tag 'block-5.14-2021-07-16' of git://git.kernel.dk/linux-block:
xen-blkfront: sanitize the removal state machine
nbd: fix order of cleaning up the queue and freeing the tagset
pd: fix order of cleaning up the queue and freeing the tagset
nvme-pci: do not call nvme_dev_remove_admin from nvme_remove
nvme-pci: fix multiple races in nvme_setup_io_queues
nvme-tcp: use __dev_get_by_name instead dev_get_by_name for OPT_HOST_IFACE
nvme_dev_remove_admin could free dev->admin_q and the admin_tagset
while they are being accessed by nvme_dev_disable(), which can be called
by nvme_reset_work via nvme_remove_dead_ctrl.
Commit cb4bfda62a ("nvme-pci: fix hot removal during error handling")
intended to avoid requests being stuck on a removed controller by killing
the admin queue. But the later fix c8e9e9b764 ("nvme-pci: unquiesce
admin queue on shutdown"), together with nvme_dev_disable(dev, true)
right before nvme_dev_remove_admin() could help dispatch requests and
fail them early, so we don't need nvme_dev_remove_admin() any more.
Fixes: cb4bfda62a ("nvme-pci: fix hot removal during error handling")
Signed-off-by: Casey Chen <cachen@purestorage.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Below two paths could overlap each other if we power off a drive quickly
after powering it on. There are multiple races in nvme_setup_io_queues()
because of shutdown_lock missing and improper use of NVMEQ_ENABLED bit.
nvme_reset_work() nvme_remove()
nvme_setup_io_queues() nvme_dev_disable()
... ...
A1 clear NVMEQ_ENABLED bit for admin queue lock
retry: B1 nvme_suspend_io_queues()
A2 pci_free_irq() admin queue B2 nvme_suspend_queue() admin queue
A3 pci_free_irq_vectors() nvme_pci_disable()
A4 nvme_setup_irqs(); B3 pci_free_irq_vectors()
... unlock
A5 queue_request_irq() for admin queue
set NVMEQ_ENABLED bit
...
nvme_create_io_queues()
A6 result = queue_request_irq();
set NVMEQ_ENABLED bit
...
fail to allocate enough IO queues:
A7 nvme_suspend_io_queues()
goto retry
If B3 runs in between A1 and A2, it will crash if irqaction haven't
been freed by A2. B2 is supposed to free admin queue IRQ but it simply
can't fulfill the job as A1 has cleared NVMEQ_ENABLED bit.
Fix: combine A1 A2 so IRQ get freed as soon as the NVMEQ_ENABLED bit
gets cleared.
After solved #1, A2 could race with B3 if A2 is freeing IRQ while B3
is checking irqaction. A3 also could race with B2 if B2 is freeing
IRQ while A3 is checking irqaction.
Fix: A2 and A3 take lock for mutual exclusion.
A3 could race with B3 since they could run free_msi_irqs() in parallel.
Fix: A3 takes lock for mutual exclusion.
A4 could fail to allocate all needed IRQ vectors if A3 and A4 are
interrupted by B3.
Fix: A4 takes lock for mutual exclusion.
If A5/A6 happened after B2/B1, B3 will crash since irqaction is not NULL.
They are just allocated by A5/A6.
Fix: Lock queue_request_irq() and setting of NVMEQ_ENABLED bit.
A7 could get chance to pci_free_irq() for certain IO queue while B3 is
checking irqaction.
Fix: A7 takes lock.
nvme_dev->online_queues need to be protected by shutdown_lock. Since it
is not atomic, both paths could modify it using its own copy.
Co-developed-by: Yuanyuan Zhong <yzhong@purestorage.com>
Signed-off-by: Casey Chen <cachen@purestorage.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
dev_get_by_name() finds network device by name but it also increases the
reference count.
If a nvme-tcp queue is present and the network device driver is removed
before nvme_tcp, we will face the following continuous log:
"kernel:unregister_netdevice: waiting for <eth> to become free. Usage count = 2"
And rmmod further halts. Similar case arises during reboot/shutdown
with nvme-tcp queue present and both never completes.
To fix this, use __dev_get_by_name() which finds network device by
name without increasing any reference counter.
Fixes: 3ede8f72a9 ("nvme-tcp: allow selecting the network interface for connections")
Signed-off-by: Omkar Kulkarni <okulkarni@marvell.com>
Signed-off-by: Shai Malin <smalin@marvell.com>
Signed-off-by: Prabhakar Kushwaha <pkushwaha@marvell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
[hch: remove the ->ndev member entirely]
Signed-off-by: Christoph Hellwig <hch@lst.de>
-----BEGIN PGP SIGNATURE-----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=gHse
-----END PGP SIGNATURE-----
Merge tag 'block-5.14-2021-07-08' of git://git.kernel.dk/linux-block
Pull more block updates from Jens Axboe:
"A combination of changes that ended up depending on both the driver
and core branch (and/or the IDE removal), and a few late arriving
fixes. In detail:
- Fix io ticks wrap-around issue (Chunguang)
- nvme-tcp sock locking fix (Maurizio)
- s390-dasd fixes (Kees, Christoph)
- blk_execute_rq polling support (Keith)
- blk-cgroup RCU iteration fix (Yu)
- nbd backend ID addition (Prasanna)
- Partition deletion fix (Yufen)
- Use blk_mq_alloc_disk for mmc, mtip32xx, ubd (Christoph)
- Removal of now dead block request types due to IDE removal
(Christoph)
- Loop probing and control device cleanups (Christoph)
- Device uevent fix (Christoph)
- Misc cleanups/fixes (Tetsuo, Christoph)"
* tag 'block-5.14-2021-07-08' of git://git.kernel.dk/linux-block: (34 commits)
blk-cgroup: prevent rcu_sched detected stalls warnings while iterating blkgs
block: fix the problem of io_ticks becoming smaller
nvme-tcp: can't set sk_user_data without write_lock
loop: remove unused variable in loop_set_status()
block: remove the bdgrab in blk_drop_partitions
block: grab a device refcount in disk_uevent
s390/dasd: Avoid field over-reading memcpy()
dasd: unexport dasd_set_target_state
block: check disk exist before trying to add partition
ubd: remove dead code in ubd_setup_common
nvme: use return value from blk_execute_rq()
block: return errors from blk_execute_rq()
nvme: use blk_execute_rq() for passthrough commands
block: support polling through blk_execute_rq
block: remove REQ_OP_SCSI_{IN,OUT}
block: mark blk_mq_init_queue_data static
loop: rewrite loop_exit using idr_for_each_entry
loop: split loop_lookup
loop: don't allow deleting an unspecified loop device
loop: move loop_ctl_mutex locking into loop_add
...
The sk_user_data pointer is supposed to be modified only while
holding the write_lock "sk_callback_lock", otherwise
we could race with other threads and crash the kernel.
we can't take the write_lock in nvmet_tcp_state_change()
because it would cause a deadlock, but the release_work queue
will set the pointer to NULL later so we can simply remove
the assignment.
Fixes: b5332a9f3f ("nvmet-tcp: fix incorrect locking in state_change sk callback")
Signed-off-by: Maurizio Lombardi <mlombard@redhat.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This series consists of the usual driver updates (ufs, ibmvfc,
megaraid_sas, lpfc, elx, mpi3mr, qedi, iscsi, storvsc, mpt3sas) with
elx and mpi3mr being new drivers. The major core change is a rework
to drop the status byte handling macros and the old bit shifted
definitions and the rest of the updates are minor fixes.
Signed-off-by: James E.J. Bottomley <jejb@linux.ibm.com>
-----BEGIN PGP SIGNATURE-----
iJwEABMIAEQWIQTnYEDbdso9F2cI+arnQslM7pishQUCYN7I6iYcamFtZXMuYm90
dG9tbGV5QGhhbnNlbnBhcnRuZXJzaGlwLmNvbQAKCRDnQslM7pishXpRAQCkngYZ
35yQrqOxgOk2pfrysE95tHrV1MfJm2U49NFTwAEAuZutEvBUTfBF+sbcJ06r6q7i
H0hkJN/Io7enFs5v3WA=
=zwIa
-----END PGP SIGNATURE-----
Merge tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi
Pull SCSI updates from James Bottomley:
"This series consists of the usual driver updates (ufs, ibmvfc,
megaraid_sas, lpfc, elx, mpi3mr, qedi, iscsi, storvsc, mpt3sas) with
elx and mpi3mr being new drivers.
The major core change is a rework to drop the status byte handling
macros and the old bit shifted definitions and the rest of the updates
are minor fixes"
* tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi: (287 commits)
scsi: aha1740: Avoid over-read of sense buffer
scsi: arcmsr: Avoid over-read of sense buffer
scsi: ips: Avoid over-read of sense buffer
scsi: ufs: ufs-mediatek: Add missing of_node_put() in ufs_mtk_probe()
scsi: elx: libefc: Fix IRQ restore in efc_domain_dispatch_frame()
scsi: elx: libefc: Fix less than zero comparison of a unsigned int
scsi: elx: efct: Fix pointer error checking in debugfs init
scsi: elx: efct: Fix is_originator return code type
scsi: elx: efct: Fix link error for _bad_cmpxchg
scsi: elx: efct: Eliminate unnecessary boolean check in efct_hw_command_cancel()
scsi: elx: efct: Do not use id uninitialized in efct_lio_setup_session()
scsi: elx: efct: Fix error handling in efct_hw_init()
scsi: elx: efct: Remove redundant initialization of variable lun
scsi: elx: efct: Fix spelling mistake "Unexected" -> "Unexpected"
scsi: lpfc: Fix build error in lpfc_scsi.c
scsi: target: iscsi: Remove redundant continue statement
scsi: qla4xxx: Remove redundant continue statement
scsi: ppa: Switch to use module_parport_driver()
scsi: imm: Switch to use module_parport_driver()
scsi: mpt3sas: Fix error return value in _scsih_expander_add()
...
We don't have an nvme status to report if the driver's .queue_rq()
returns an error without dispatching the requested nvme command. Check
the return value from blk_execute_rq() for all passthrough commands so
the caller may know their command was not successful.
If the command is from the target passthrough interface and fails to
dispatch, synthesize the response back to the host as a internal target
error.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Link: https://lore.kernel.org/r/20210610214437.641245-5-kbusch@kernel.org
Signed-off-by: Jens Axboe <axboe@kernel.dk>
The generic blk_execute_rq() knows how to handle polled completions. Use
that instead of implementing an nvme specific handler.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Link: https://lore.kernel.org/r/20210610214437.641245-3-kbusch@kernel.org
Signed-off-by: Jens Axboe <axboe@kernel.dk>
-----BEGIN PGP SIGNATURE-----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=D6dS
-----END PGP SIGNATURE-----
Merge tag 'for-5.14/drivers-2021-06-29' of git://git.kernel.dk/linux-block
Pull block driver updates from Jens Axboe:
"Pretty calm round, mostly just NVMe and a bit of MD:
- NVMe updates (via Christoph)
- improve the APST configuration algorithm (Alexey Bogoslavsky)
- look for StorageD3Enable on companion ACPI device
(Mario Limonciello)
- allow selecting the network interface for TCP connections
(Martin Belanger)
- misc cleanups (Amit Engel, Chaitanya Kulkarni, Colin Ian King,
Christoph)
- move the ACPI StorageD3 code to drivers/acpi/ and add quirks
for certain AMD CPUs (Mario Limonciello)
- zoned device support for nvmet (Chaitanya Kulkarni)
- fix the rules for changing the serial number in nvmet
(Noam Gottlieb)
- various small fixes and cleanups (Dan Carpenter, JK Kim,
Chaitanya Kulkarni, Hannes Reinecke, Wesley Sheng, Geert
Uytterhoeven, Daniel Wagner)
- MD updates (Via Song)
- iostats rewrite (Guoqing Jiang)
- raid5 lock contention optimization (Gal Ofri)
- Fall through warning fix (Gustavo)
- Misc fixes (Gustavo, Jiapeng)"
* tag 'for-5.14/drivers-2021-06-29' of git://git.kernel.dk/linux-block: (78 commits)
nvmet: use NVMET_MAX_NAMESPACES to set nn value
loop: Fix missing discard support when using LOOP_CONFIGURE
nvme.h: add missing nvme_lba_range_type endianness annotations
nvme: remove zeroout memset call for struct
nvme-pci: remove zeroout memset call for struct
nvmet: remove zeroout memset call for struct
nvmet: add ZBD over ZNS backend support
nvmet: add Command Set Identifier support
nvmet: add nvmet_req_bio put helper for backends
nvmet: add req cns error complete helper
block: export blk_next_bio()
nvmet: remove local variable
nvmet: use nvme status value directly
nvmet: use u32 type for the local variable nsid
nvmet: use u32 for nvmet_subsys max_nsid
nvmet: use req->cmd directly in file-ns fast path
nvmet: use req->cmd directly in bdev-ns fast path
nvmet: make ver stable once connection established
nvmet: allow mn change if subsys not discovered
nvmet: make sn stable once connection was established
...
For Spec regarding MNAN value:-
If the controller supports Asymmetric Namespace Access Reporting, then
this field shall be set to a non-zero value that is less than or equal
to the NN value.
Instead of using subsys->max_nsid that gets calculated dynamically,
use NVMET_MAX_NAMESPACES value to report NN. This way we will maintain
the MNAN value spec compliant with NN.
Without this patch, code results in the following error :-
[337976.409142] nvme nvme1: Invalid MNAN value 1024
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variables to zero values so that we can
remove zeroout memset calls in the host/core.c.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variables to zero values so that we can
remove zeroout memset calls in the host/pci.c.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variables to zero values so that we can
remove zeroout memset calls in the target/rdma.c.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMe TP 4053 – Zoned Namespaces (ZNS) allows host software to
communicate with a non-volatile memory subsystem using zones for NVMe
protocol-based controllers. NVMeOF already support the ZNS NVMe
Protocol compliant devices on the target in the passthru mode. There
are generic zoned block devices like Shingled Magnetic Recording (SMR)
HDDs that are not based on the NVMe protocol.
This patch adds ZNS backend support for non-ZNS zoned block devices as
NVMeOF targets.
This support includes implementing the new command set NVME_CSI_ZNS,
adding different command handlers for ZNS command set such as NVMe
Identify Controller, NVMe Identify Namespace, NVMe Zone Append,
NVMe Zone Management Send and NVMe Zone Management Receive.
With the new command set identifier, we also update the target command
effects logs to reflect the ZNS compliant commands.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMe TP 4056 allows controllers to support different command sets.
NVMeoF target currently only supports namespaces that contain
traditional logical blocks that may be randomly read and written. In
some applications there is a value in exposing namespaces that contain
logical blocks that have special access rules (e.g. sequentially write
required namespace such as Zoned Namespace (ZNS)).
In order to support the Zoned Block Devices (ZBD) backend, controllers
need to have support for ZNS Command Set Identifier (CSI).
In this preparation patch, we adjust the code such that it can now
support the default command set identifier. We update the namespace data
structure to store the CSI value which defaults to NVME_CSI_NVM
that represents traditional logical blocks namespace type.
The CSI support is required to implement the ZBD backend for NVMeOF
with host side NVMe ZNS interface, since ZNS commands belong to
the different command set than the default one.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In current code there exists two backends which are using inline bio
optimization, that adds a duplicate code for freeing the bio.
For Zoned Block Device backend we also use the same optimzation and it
will lead to having duplicate code in the three backends: generic
bdev, passsthru, and generic zns.
Add a helper function to avoid duplicate code and update the respective
backends.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We report error and complete the request when identify cns value is not
handled in nvmet_execute_identify(). This error reporting is also needed
for Zone Block Device backend for NVMeOF target.
Add a helper nvmet_req_cns_error_compplete() to report an error and
complete the request when idenitfy command cns not handled value.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In function errno_to_nvme_status() we store the value of the NVMe
status into the local variable and don't do anything useful with that
but just return.
Remove the local variable and return the value directly from switch.
This also removed extra break statements.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is no point in keeping the status variable that is used only once
in the function nvmet_async_events_failall().
Remove the variable and use the value directly.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In function nvmet_max_nsid() we calculate the max nsid by iterating
over the XArray and store it in the variable nsid that has type of
unsigned long.
Since the value of this function is stored into the subsys->max_nsid
which is of type u32, change the local variable nsid type and the return
type of the same function to u32.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use u32 type for the nsid_max member of the nvmet_subsys structure.
This avoids the type confusion when updating the subsys->nax_nsid from
ns->nsid. This also matches the nvmet_ns->nsid member.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_file_parse_io_cmd() is called from the fast path. The
local variable to that function cmd is only used once.
Remove the local variable and use req->cmd directly.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_bdev_parse_io_cmd() is called from the fast path.
The local variable to that function cmd is only used once.
Remove the local variable and use req->cmd directly.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Once some host has connected to the nvmf target, make sure that the
version number is stable and cannot be changed.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Currently, once the subsystem's model_number is set for the first time
there is no way to change it. However, as long as no connection was
established to nvmf target, there is no reason for such restriction and
we should allow to change the subsystem's model_number as many times as
needed.
In addition, in order to simplfy the changes and make the model number
flow more similar to the rest of the attributes in the Identify
Controller data structure, we set a default value for the model number
at the initiation of the subsystem.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Once some host has connected to the target, make sure that the serial
number is stable and cannot be changed.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVM specification, the serial_number should be 20 bytes
(bytes 23:04 of the Identify Controller data structure), and should
contain only ASCII characters.
In accordance, the serial_number size is changed to 20 bytes and before
any attempt to store a new value in serial_number we check that the
input is valid - i.e. contains only ASCII characters, is not empty and
does not exceed 20 bytes.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When parsing a request in nvmet_fc_handle_fcp_rqst() we should not
check for invalid target ports; if we do the command is aborted
from the fcp layer, causing the host to assume a transport error.
Rather we should still forward this request to the nvmet layer, which
will then correctly fail the command with an appropriate error status.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Declare and initialize structure variable to the zero values so that we
can get rid of the zeroout memset call.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the helper to check NVMe controller's SGL support.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the helper to check NVMe controller's SGL support.
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For various transports such as fc/tcp/pci it is common to check if
NVMe SGLs are supported or not by the controller.
In this preparation patch we add a helper to avoid the open coding of
such checks in the various transport.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the extra white line at the end of the functions.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvmeq->cq_head is compared with nvmeq->q_depth and changed the value
and cq_phase for handling the next cq db.
but, nvmeq->q_depth's type is u32 and max. value is 0x10000 when
CQP.MSQE is 0xffff and io_queue_depth is 0x10000.
current temp. variable for comparing with nvmeq->q_depth is overflowed
when previous nvmeq->cq_head is 0xffff.
in this case, nvmeq->cq_phase is not updated.
so, fix data type for temp. variable to u32.
Signed-off-by: JK Kim <jongkang.kim2@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
These error paths currently return success but they should return
-EOPNOTSUPP.
Fixes: 73ffcefcfc ("nvme-tcp: check sgl supported by target")
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add a helper nvme_validate_passthru_nsid() to validate the nsid that
removes the nsid validation and error message print code from
nvme_user_cmd() and nvme_user_cmd64().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Fix a singular/plural mismatch in the CONFIG_NVME_MULTIPATH help text.
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commit ce86dad222 ("nvme-multipath: reset bdev to ns head when
failover") moved the reset code where the bio is added to the
requeue_list for the failover path. But it left the original
bio_set_dev in nvme_requeue_work.
There is a second path to nvme_requee_work. It is via
nvme_ns_head_submit_bio. Though we don't have to set bio->bi_bdev for
this path either, as it points to the correct bdev already.
Let's remove the bio_set_dev. It's updating the bio->bi_bdev with the
same pointer and thus it's unnecessary.
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The controller is required to have a non-zero MNAN value if it supports
ANA:
If the controller supports Asymmetric Namespace Access Reporting, then
this field shall be set to a non-zero value that is less than or equal
to the NN value.
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Although first implemented for NVME, this check may be usable by
other drivers as well. Microsoft's specification explicitly mentions
that is may be usable by SATA and AHCI devices. Google also indicates
that they have used this with SDHCI in a downstream kernel tree that
a user can plug a storage device into.
Link: https://docs.microsoft.com/en-us/windows-hardware/design/component-guidelines/power-management-for-storage-hardware-devices-intro
Suggested-by: Keith Busch <kbusch@kernel.org>
CC: Shyam-sundar S-k <Shyam-sundar.S-k@amd.com>
CC: Alexander Deucher <Alexander.Deucher@amd.com>
CC: Rafael J. Wysocki <rjw@rjwysocki.net>
CC: Prike Liang <prike.liang@amd.com>
Signed-off-by: Mario Limonciello <mario.limonciello@amd.com>
Reviewed-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add a new sysfs attribute, appid_store, which can be used to set the
application identifier in the blkcg associated with a cgroup id.
Below is the interface provided to set the app_id:
echo "<cgroupid>:<appid>" >> /sys/class/fc/fc_udev_device/appid_store
echo "457E:100000109b521d27" >> /sys/class/fc/fc_udev_device/appid_store
Link: https://lore.kernel.org/r/20210608043556.274139-4-muneendra.kumar@broadcom.com
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Muneendra Kumar <muneendra.kumar@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Remove the superfluous variable "bdev" that is only used once in the
nvmet_bdev_alloc_bip() and use req->ns->bdev that is used everywhere in
the code to access the nvmet request's bdev.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Initialize keep-alive work only once, as part of alloc_ctrl
and not each time that nvmet_start_keep_alive_timer is being called
Signed-off-by: Amit Engel <amit.engel@dell.com>
Reviewed-by: Hou Pu <houpu.main@gmail.com>
Now that only one caller is left remove the helpers by restructuring
nvme_pr_command so that it has two helpers for sending a command of to a
given nsid using either the ns_head for multipath, or the namespace
stored in the gendisk.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Split multipath support out of nvme_report_zones into a separate helper
and simplify the non-multipath version as a result.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Move the CSI check into nvme_ns_report_zones to clean up the code
a little bit and prepare for further refactoring.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Add the __releases annotation to tell sparse that nvme_ns_head_ctrl_ioctl
is expected to unlock head->srcu.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
nvme_ns_head_ctrl_ioctl is always used on multipath nodes, so just call
srcu_read_unlock directly.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
nvme_ns_head_ioctl is always used on multipath nodes, no need to
deal with the de-multiplexers.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
nvme_ns_head_chr_ioctl is always used on multipath nodes, so just call
srcu_read_unlock and consolidate the two unlock paths.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
No need to use the braces around ~ operator.
No functionality change in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the comment at the end of the switch that is not needed as
function is small enough.
No functionality change in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the extra lines in the switch block that is not common practice
in the kernel code.
No functionality change in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Fix the comment style that matches existing code.
No functionality change in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In our application, we need a way to force TCP connections to go out a
specific IP interface instead of letting Linux select the interface
based on the routing tables.
Add the 'host-iface' option to allow specifying the interface to use.
When the option host-iface is specified, the driver uses the specified
interface to set the option SO_BINDTODEVICE on the TCP socket before
connecting.
This new option is needed in addtion to the existing host-traddr for
the following reasons:
Specifying an IP interface by its associated IP address is less
intuitive than specifying the actual interface name and, in some cases,
simply doesn't work. That's because the association between interfaces
and IP addresses is not predictable. IP addresses can be changed or can
change by themselves over time (e.g. DHCP). Interface names are
predictable [1] and will persist over time. Consider the following
configuration.
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state ...
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 100.0.0.100/24 scope global lo
valid_lft forever preferred_lft forever
2: enp0s3: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:21:65:ec brd ff:ff:ff:ff:ff:ff
inet 100.0.0.100/24 scope global enp0s3
valid_lft forever preferred_lft forever
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
inet 100.0.0.100/24 scope global enp0s8
valid_lft forever preferred_lft forever
The above is a VM that I configured with the same IP address
(100.0.0.100) on all interfaces. Doing a reverse lookup to identify the
unique interface associated with 100.0.0.100 does not work here. And
this is why the option host_iface is required. I understand that the
above config does not represent a standard host system, but I'm using
this to prove a point: "We can never know how users will configure
their systems". By te way, The above configuration is perfectly fine
by Linux.
The current TCP implementation for host_traddr performs a
bind()-before-connect(). This is a common construct to set the source
IP address on a TCP socket before connecting. This has no effect on how
Linux selects the interface for the connection. That's because Linux
uses the Weak End System model as described in RFC1122 [2]. On the other
hand, setting the Source IP Address has benefits and should be supported
by linux-nvme. In fact, setting the Source IP Address is a mandatory
FedGov requirement (e.g. connection to a RADIUS/TACACS+ server).
Consider the following configuration.
$ ip addr list dev enp0s8
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
inet 192.168.56.101/24 brd 192.168.56.255 scope global enp0s8
valid_lft 426sec preferred_lft 426sec
inet 192.168.56.102/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
inet 192.168.56.103/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
inet 192.168.56.104/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
Here we can see that several addresses are associated with interface
enp0s8. By default, Linux always selects the default IP address,
192.168.56.101, as the source address when connecting over interface
enp0s8. Some users, however, want the ability to specify a different
source address (e.g., 192.168.56.102, 192.168.56.103, ...). The option
host_traddr can be used as-is to perform this function.
In conclusion, I believe that we need 2 options for TCP connections.
One that can be used to specify an interface (host-iface). And one that
can be used to set the source address (host-traddr). Users should be
allowed to use one or the other, or both, or none. Of course, the
documentation for host_traddr will need some clarification. It should
state that when used for TCP connection, this option only sets the
source address. And the documentation for host_iface should say that
this option is only available for TCP connections.
References:
[1] https://www.freedesktop.org/wiki/Software/systemd/PredictableNetworkInterfaceNames/
[2] https://tools.ietf.org/html/rfc1122
Tested both IPv4 and IPv6 connections.
Signed-off-by: Martin Belanger <martin.belanger@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The algorithm that was used until now for building the APST configuration
table has been found to produce entries with excessively long ITPT
(idle time prior to transition) for devices declaring relatively long
entry and exit latencies for non-operational power states. This leads
to unnecessary waste of power and, as a result, failure to pass
mandatory power consumption tests on Chromebook platforms.
The new algorithm is based on two predefined ITPT values and two
predefined latency tolerances. Based on these values, as well as on
exit and entry latencies reported by the device, the algorithm looks
for up to 2 suitable non-operational power states to use as primary
and secondary APST transition targets. The predefined values are
supplied to the nvme driver as module parameters:
- apst_primary_timeout_ms (default: 100)
- apst_secondary_timeout_ms (default: 2000)
- apst_primary_latency_tol_us (default: 15000)
- apst_secondary_latency_tol_us (default: 100000)
The algorithm echoes the approach used by Intel's and Microsoft's drivers
on Windows. The specific default parameter values are also based on those
drivers. Yet, this patch doesn't introduce the ability to dynamically
regenerate the APST table in the event of switching the power source from
AC to battery and back. Adding this functionality may be considered in the
future. In the meantime, the timeouts and tolerances reflect a compromise
between values used by Microsoft for AC and battery scenarios.
In most NVMe devices the new algorithm causes them to implement a more
aggressive power saving policy. While beneficial in most cases, this
sometimes comes at the price of a higher IO processing latency in certain
scenarios as well as at the price of a potential impact on the drive's
endurance (due to more frequent context saving when entering deep non-
operational states). So in order to provide a fallback for systems where
these regressions cannot be tolerated, the patch allows to revert to
the legacy behavior by setting either apst_primary_timeout_ms or
apst_primary_latency_tol_us parameter to 0. Eventually (and possibly after
fine tuning the default values of the module parameters) the legacy behavior
can be removed.
TESTING.
The new algorithm has been extensively tested. Initially, simulations were
used to compare APST tables generated by old and new algorithms for a wide
range of devices. After that, power consumption, performance and latencies
were measured under different workloads on devices from multiple vendors
(WD, Intel, Samsung, Hynix, Kioxia). Below is the description of the tests
and the findings.
General observations.
The effect the patch has on the APST table varies depending on the entry and
exit latencies advertised by the devices. For some devices, the effect is
negligible (e.g. Kioxia KBG40ZNS), for some significant, making the
transitions to PS3 and PS4 much quicker (e.g. WD SN530, Intel 760P), or making
the sleep deeper, PS4 rather than PS3 after a similar amount of time (e.g.
SK Hynix BC511). For some devices (e.g. Samsung PM991) the effect is mixed:
the initial transition happens after a longer idle time, but takes the device
to a lower power state.
Workflows.
In order to evaluate the patch's effect on the power consumption and latency,
7 workflows were used for each device. The workflows were designed to test
the scenarios where significant differences between the old and new behaviors
are most likely. Each workflow was tested twice: with the new and with the
old APST table generation implementation. Power consumption, performance and
latency were measured in the process. The following workflows were used:
1) Consecutive write at the maximum rate with IO depth of 2, with no pauses
2) Repeated pattern of 1000 consecutive writes of 4K packets followed by 50ms
idle time
3) Repeated pattern of 1000 consecutive writes of 4K packets followed by 150ms
idle time
4) Repeated pattern of 1000 consecutive writes of 4K packets followed by 500ms
idle time
5) Repeated pattern of 1000 consecutive writes of 4K packets followed by 1.5s
idle time
6) Repeated pattern of 1000 consecutive writes of 4K packets followed by 5s
idle time
7) Repeated pattern of a single random read of a 4K packet followed by 150ms
idle time
Power consumption
Actual power consumption measurements produced predictable results in
accordance with the APST mechanism's theory of operation.
Devices with long entry and exit latencies such as WD SN530 showed huge
improvement on scenarios 4,5 and 6 of up to 62%. Devices such as Kioxia
KBG40ZNS where the resulting APST table looks virtually identical with
both legacy and new algorithms, showed little or no change in the average power
consumption on all workflows. Devices with extra short latencies such as
Samsung PM991 showed moderate increase in power consumption of up to 18% in
worst case scenarios.
In addition, on Intel and Samsung devices a more complex impact was observed
on scenarios 3, 4 and 7. Our understanding is that due to longer stay in deep
non-operational states between the writes the devices start performing background
operations leading to an increase of power consumption. With the old APST tables
part of these operations are delayed until the scenario is over and a longer idle
period begins, but eventually this extra power is consumed anyway.
Performance.
In terms of performance measured on sustained write or read scenarios, the
effect of the patch is minimal as in this case the device doesn't enter low power
states.
Latency
As expected, in devices where the patch causes a more aggressive power saving
policy (e.g. WD SN530, Intel 760P), an increase in latency was observed in
certain scenarios. Workflow number 7, specifically designed to simulate the
worst case scenario as far as latency is concerned, indeed shows a sharp
increase in average latency (~2ms -> ~53ms on Intel 760P and 0.6 -> 10ms on
WD SN530). The latency increase on other workloads and other devices is much
milder or non-existent.
Signed-off-by: Alexey Bogoslavsky <alexey.bogoslavsky@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The variable ret is being initialized with a value that is never read,
it is being updated later on. The assignment is redundant and can be
removed.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case p2p device was found but the p2p pool is empty, the nvme target
is still trying to free the sgl from the p2p pool instead of the
regular sgl pool and causing a crash (BUG() is called). Instead, assign
the p2p_dev for the request only if it was allocated from p2p pool.
This is the crash that was caused:
[Sun May 30 19:13:53 2021] ------------[ cut here ]------------
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
[Sun May 30 19:13:53 2021] invalid opcode: 0000 [#1] SMP PTI
...
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
...
[Sun May 30 19:13:53 2021] RIP: 0010:gen_pool_free_owner+0xa8/0xb0
...
[Sun May 30 19:13:53 2021] Call Trace:
[Sun May 30 19:13:53 2021] ------------[ cut here ]------------
[Sun May 30 19:13:53 2021] pci_free_p2pmem+0x2b/0x70
[Sun May 30 19:13:53 2021] pci_p2pmem_free_sgl+0x4f/0x80
[Sun May 30 19:13:53 2021] nvmet_req_free_sgls+0x1e/0x80 [nvmet]
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
[Sun May 30 19:13:53 2021] nvmet_rdma_release_rsp+0x4e/0x1f0 [nvmet_rdma]
[Sun May 30 19:13:53 2021] nvmet_rdma_send_done+0x1c/0x60 [nvmet_rdma]
Fixes: c6e3f13398 ("nvmet: add metadata support for block devices")
Reviewed-by: Israel Rukshin <israelr@nvidia.com>
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
During concurrent reset and delete calls the reset workqueue is
flushed, causing nvme_loop_reset_ctrl_work() to be executed when
the controller is in state DELETING or DELETING_NOIO.
But this is expected, so we shouldn't issue a WARN_ON here.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We need to check the NVME_LOOP_Q_LIVE flag in
nvme_loop_destroy_admin_queue() to protect against duplicate
invocations eg during concurrent reset and remove calls.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When the call to nvme_enable_ctrl() in nvme_loop_configure_admin_queue()
fails the NVME_LOOP_Q_LIVE flag is not cleared.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The queue count is increased in nvme_loop_init_io_queues(), so we
need to reset it to 1 at the end of nvme_loop_destroy_io_queues().
Otherwise the function is not re-entrant safe, and crash will happen
during concurrent reset and remove calls.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Convert the nvme-multipath driver to use the blk_alloc_disk and
blk_cleanup_disk helpers to simplify gendisk and request_queue
allocation.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Link: https://lore.kernel.org/r/20210521055116.1053587-19-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Automatically set the GENHD_FL_EXT_DEVT flag for all disks allocated
without an explicit number of minors. This is what all new block
drivers should do, so make sure it is the default without boilerplate
code.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Luis Chamberlain <mcgrof@kernel.org>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Link: https://lore.kernel.org/r/20210521055116.1053587-4-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
We have only 2 inline sg entries and we allow 4 sg entries for the send
wr sge. Larger sgls entries will be chained. However when we build
in-capsule send wr sge, we iterate without taking into account that the
sgl may be chained and still fit in-capsule (which can happen if the sgl
is bigger than 2, but lower-equal to 4).
Fix in-capsule data mapping to correctly iterate chained sgls.
Fixes: 38e1800275 ("nvme-rdma: Avoid preallocating big SGL for data")
Reported-by: Walker, Benjamin <benjamin.walker@intel.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Controller teardown flow may take some time in case it has many I/O
queues, and the host may not send us keep-alive during this period.
Hence reset the traffic based keep-alive timer so we don't trigger
a controller teardown as a result of a keep-alive expiration.
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Tested-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Using "<=" instead "<" to compare inline data size.
Fixes: bdaf132791 ("nvmet-tcp: fix a segmentation fault during io parsing error")
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We need to select NVME_CORE.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Returning an nvme status from nvme_fc_create_association() indicates
that the association is established, and we should honour the DNR bit.
If it's set a reconnect attempt will just return the same error, so
we can short-circuit the reconnect attempts and fail the connection
directly.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The __nvmf_check_ready() routine used to bounce all filesystem io if the
controller state isn't LIVE. However, a later patch changed the logic so
that it rejection ends up being based on the Q live check. The FC
transport has a slightly different sequence from rdma and tcp for
shutting down queues/marking them non-live. FC marks its queue non-live
after aborting all ios and waiting for their termination, leaving a
rather large window for filesystem io to continue to hit the transport.
Unfortunately this resulted in filesystem I/O or applications seeing I/O
errors.
Change the FC transport to mark the queues non-live at the first sign of
teardown for the association (when I/O is initially terminated).
Fixes: 73a5379937 ("nvme-fabrics: allow to queue requests for live queues")
Signed-off-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A possible race condition exists where the request to send data is
enqueued from nvme_tcp_handle_r2t()'s will not be observed by
nvme_tcp_send_all() if it happens to be running. The driver relies on
io_work to send the enqueued request when it is runs again, but the
concurrently running nvme_tcp_send_all() may not have released the
send_mutex at that time. If no future commands are enqueued to re-kick
the io_work, the request will timeout in the SEND_H2C state, resulting
in a timeout error like:
nvme nvme0: queue 1: timeout request 0x3 type 6
Ensure the io_work continues to run as long as the req_list is not empty.
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commit db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq
context") added a second context that may perform a network send.
This means that now RX and TX are not serialized in nvme_tcp_io_work
and can run concurrently.
While there is correct mutual exclusion in the TX path (where
the send_mutex protect the queue socket send activity) RX activity,
and more specifically request completion may run concurrently.
This means we must guarantee that any mutation of the request state
related to its lifetime, bytes sent must not be accessed when a completion
may have possibly arrived back (and processed).
The race may trigger when a request completion arrives, processed
_and_ reused as a fresh new request, exactly in the (relatively short)
window between the last data payload sent and before the request iov_iter
is advanced.
Consider the following race:
1. 16K write request is queued
2. The nvme command and the data is sent to the controller (in-capsule
or solicited by r2t)
3. After the last payload is sent but before the req.iter is advanced,
the controller sends back a completion.
4. The completion is processed, the request is completed, and reused
to transfer a new request (write or read)
5. The new request is queued, and the driver reset the request parameters
(nvme_tcp_setup_cmd_pdu).
6. Now context in (2) resumes execution and advances the req.iter
==> use-after-completion as this is already a new request.
Fix this by making sure the request is not advanced after the last
data payload send, knowing that a completion may have arrived already.
An alternative solution would have been to delay the request completion
or state change waiting for reference counting on the TX path, but besides
adding atomic operations to the hot-path, it may present challenges in
multi-stage R2T scenarios where a r2t handler needs to be deferred to
an async execution.
Reported-by: Narayan Ayalasomayajula <narayan.ayalasomayajula@wdc.com>
Tested-by: Anil Mishra <anil.mishra@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Cc: stable@vger.kernel.org # v5.8+
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When creating loop ctrl in nvme_loop_create_ctrl(), if nvme_init_ctrl()
fails, the loop ctrl should be freed before jumping to the "out" label.
Fixes: 3a85a5de29 ("nvme-loop: add a NVMe loopback host driver")
Signed-off-by: Wu Bo <wubo40@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When creating ctrl in nvmet_alloc_ctrl(), if the cntlid_min is larger
than cntlid_max of the subsystem, and jumps to the
"out_free_changed_ns_list" label, but the ctrl->sqs lack of be freed.
Fix this by jumping to the "out_free_sqs" label.
Fixes: 94a39d61f8 ("nvmet: make ctrl-id configurable")
Signed-off-by: Wu Bo <wubo40@huawei.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reset the ns->file value to NULL also in the error case in
nvmet_file_ns_enable().
The ns->file variable points either to file object or contains the
error code after the filp_open() call. This can lead to following
problem:
When the user first setups an invalid file backend and tries to enable
the ns, it will fail. Then the user switches over to a bdev backend
and enables successfully the ns. The first received I/O will crash the
system because the IO backend is chosen based on the ns->file value:
static u16 nvmet_parse_io_cmd(struct nvmet_req *req)
{
[...]
if (req->ns->file)
return nvmet_file_parse_io_cmd(req);
return nvmet_bdev_parse_io_cmd(req);
}
Reported-by: Enzo Matsumiya <ematsumiya@suse.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Host can send invalid commands and flood the target with error messages.
Demote the error message from pr_err() to pr_debug() in
nvmet_parse_fabrics_cmd() and nvmet_parse_connect_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the helper nvmet_report_invalid_opcode() to report invalid opcode
so we can remove the duplicate code.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Host can send invalid commands and flood the target with error messages
for the discovery controller. Demote the error message from pr_err() to
pr_debug( in nvmet_parse_discovery_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When handling passthru commands, for inline bio allocation we only
consider the transfer size. This works well when req->sg_cnt fits into
the req->inline_bvec, but it will result in the early return from
bio_add_hw_page() when req->sg_cnt > NVMET_MAX_INLINE_BVEC.
Consider an I/O of size 32768 and first buffer is not aligned to the
page boundary, then I/O is split in following manner :-
[ 2206.256140] nvmet: sg->length 3440 sg->offset 656
[ 2206.256144] nvmet: sg->length 4096 sg->offset 0
[ 2206.256148] nvmet: sg->length 4096 sg->offset 0
[ 2206.256152] nvmet: sg->length 4096 sg->offset 0
[ 2206.256155] nvmet: sg->length 4096 sg->offset 0
[ 2206.256159] nvmet: sg->length 4096 sg->offset 0
[ 2206.256163] nvmet: sg->length 4096 sg->offset 0
[ 2206.256166] nvmet: sg->length 4096 sg->offset 0
[ 2206.256170] nvmet: sg->length 656 sg->offset 0
Now the req->transfer_size == NVMET_MAX_INLINE_DATA_LEN i.e. 32768, but
the req->sg_cnt is (9) > NVMET_MAX_INLINE_BIOVEC which is (8).
This will result in early return in the following code path :-
nvmet_bdev_execute_rw()
bio_add_pc_page()
bio_add_hw_page()
if (bio_full(bio, len))
return 0;
Use previously introduced helper nvmet_use_inline_bvec() to consider
req->sg_cnt when using inline bio. This only affects nvme-loop
transport.
Fixes: dab3902b19 ("nvmet: use inline bio for passthru fast path")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When handling rw commands, for inline bio case we only consider
transfer size. This works well when req->sg_cnt fits into the
req->inline_bvec, but it will result in the warning in
__bio_add_page() when req->sg_cnt > NVMET_MAX_INLINE_BVEC.
Consider an I/O size 32768 and first page is not aligned to the page
boundary, then I/O is split in following manner :-
[ 2206.256140] nvmet: sg->length 3440 sg->offset 656
[ 2206.256144] nvmet: sg->length 4096 sg->offset 0
[ 2206.256148] nvmet: sg->length 4096 sg->offset 0
[ 2206.256152] nvmet: sg->length 4096 sg->offset 0
[ 2206.256155] nvmet: sg->length 4096 sg->offset 0
[ 2206.256159] nvmet: sg->length 4096 sg->offset 0
[ 2206.256163] nvmet: sg->length 4096 sg->offset 0
[ 2206.256166] nvmet: sg->length 4096 sg->offset 0
[ 2206.256170] nvmet: sg->length 656 sg->offset 0
Now the req->transfer_size == NVMET_MAX_INLINE_DATA_LEN i.e. 32768, but
the req->sg_cnt is (9) > NVMET_MAX_INLINE_BIOVEC which is (8).
This will result in the following warning message :-
nvmet_bdev_execute_rw()
bio_add_page()
__bio_add_page()
WARN_ON_ONCE(bio_full(bio, len));
This scenario is very hard to reproduce on the nvme-loop transport only
with rw commands issued with the passthru IOCTL interface from the host
application and the data buffer is allocated with the malloc() and not
the posix_memalign().
Fixes: 73383adfad ("nvmet: don't split large I/Os unconditionally")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_init_identify and thus nvme_mpath_init can be called multiple
times and thus must not overwrite potentially initialized or in-use
fields. Split out a helper for the basic initialization when the
controller is initialized and make sure the init_identify path does
not blindly change in-use data structures.
Fixes: 0d0b660f21 ("nvme: add ANA support")
Reported-by: Martin Wilck <mwilck@suse.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Nothing can stop a host from submitting invalid commands. The target
just needs to respond with an appropriate status, but that's not a
target error. Demote invalid command messages to the debug level so
these events don't spam the kernel logs.
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a request finally completes in end_io() after it has failed over,
the bdev pointer can be stale and thus the system can crash. Set the
bdev back to ns head, so the request is map to an active path when
resubmitted.
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
reset_work() in nvme-pci may hang forever in the following scenario:
1) A reset caused by a command timeout occurs due to a controller being
temporarily irresponsive.
2) nvme_reset_work() restarts admin queue at nvme_alloc_admin_tags(). At
the same time, a user-submitted admin command is queued and waiting
for completion. Then, reset_work() changes its state to CONNECTING,
and submits an identify command.
3) However, the controller does still not respond to any command,
causing a timeout being fired at the user-submitted command.
Unfortunately, nvme_timeout() does not see the completion on cq, and
any timeout that takes place under CONNECTING state causes a
controller shutdown.
4) Normally, the identify command in reset_work() would be canceled with
SC_HOST_ABORTED by nvme_dev_disable(), then reset_work can tear down
the controller accordingly. But the controller happens to return
online and respond the identify command before nvme_dev_disable()
should have been reaped it off.
5) reset_work() continues to setup_io_queues() as it observes no error
in init_identify(). However, the admin queue has already been
quiesced in dev_disable(). Thus, any following commands would be
blocked forever in blk_execute_rq().
This can be fixed by restricting usercmd commands when controller is not
in a LIVE state in nvme_queue_rq(), as what has been done previously in
fabrics.
```
nvme_reset_work(): |
nvme_alloc_admin_tags() |
| nvme_submit_user_cmd():
nvme_init_identify(): | ...
__nvme_submit_sync_cmd(): |
... | ...
---------------------------------------> nvme_timeout():
(Controller starts reponding commands) | nvme_dev_disable(, true):
nvme_setup_io_queues(): |
__nvme_submit_sync_cmd(): |
(hung in blk_execute_rq |
since run_hw_queue sees |
queue quiesced) |
```
Signed-off-by: Tao Chiu <taochiu@synology.com>
Signed-off-by: Cody Wong <codywong@synology.com>
Reviewed-by: Leon Chien <leonchien@synology.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
queue_rq() in pci only checks if the dispatched queue (nvmeq) is ready,
e.g. not being suspended. Since nvme_alloc_admin_tags() in reset flow
restarts the admin queue, users are able to submit admin commands to a
controller before reset_work() completes. Commands submitted under this
condition may interfere with commands that performs identify, IO queue
setup in reset_work(), and may result in a hang described in the
following patch.
As seen in the fabrics, user commands are prevented from being executed
under inproper controller states. We may reuse this logic to maintain a
clear admin queue during reset_work().
Signed-off-by: Tao Chiu <taochiu@synology.com>
Signed-off-by: Cody Wong <codywong@synology.com>
Reviewed-by: Leon Chien <leonchien@synology.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_clear_nvme_request() clears the nvme_command, which is unncessary
for passthrough requests as nvme_command is overwritten immediately.
Move clearing part from this helper to the caller, so that double memset
for passthrough requests is avoided.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In multipath case, we should consider namespace attachment with
controllers in a subsystem when we find out the live controller for the
namespace. This patch manually reverted the commit 3557a44097
("nvme: don't bother to look up a namespace for controller ioctls") with
few more updates to nvme_ns_head_chr_ioctl which has been newly updated.
Fixes: 3557a44097 ("nvme: don't bother to look up a namespace for
controller ioctls")
Cc: Christoph Hellwig <hch@lst.de>
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Userspace has not been allowed to I/O to device that's failed to
be initialized. This patch introduces generic per-namespace character
device to allow userspace to I/O regardless the block device is there or
not.
The chardev naming convention will similar to the existing blkdev naming,
using a ng prefix instead of nvme, i.e.
- /dev/ngXnY
It also supports multipath which means it will not expose chardev for the
hidden namespace blkdevs (e.g., nvmeXcYnZ). If /dev/ngXnY is created for
a ns_head, then I/O request will be routed to a specific controller
selected by the iopolicy of the subsystem.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Tested-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove a level of indentation from the main code implementating the table
search by using a goto for the APST not supported case. Also move the
main comment above the function.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Niklas Cassel <niklas.cassel@wdc.com>
Do not call nvme_configure_apst when the controller is not live, given
that nvme_configure_apst will fail due the lack of an admin queue when
the controller is being torn down and nvme_set_latency_tolerance is
called from dev_pm_qos_hide_latency_tolerance.
Fixes: 510a405d945b("nvme: fix memory leak for power latency tolerance")
Reported-by: Peng Liu <liupeng17@lenovo.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Add a 'kato' controller sysfs attribute to display the current
keep-alive timeout value (if any). This allows userspace to identify
persistent discovery controllers, as these will have a non-zero
KATO value.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVMe base spec the KATO commands should be sent
at half of the KATO interval, to properly account for round-trip
times.
As we now will only ever send one KATO command per connection we
can easily use the recommended values.
This also fixes a potential issue where the request timeout for
the KATO command does not match the value in the connect command,
which might be causing spurious connection drops from the target.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Issue following command:
nvme set-feature -f 0xf -v 0 /dev/nvme1n1 # disable keep-alive timer
nvme admin-passthru -o 0x18 /dev/nvme1n1 # send keep-alive command
will make keep-alive timer fired and thus delete the controller like
below:
[247459.907635] nvmet: ctrl 1 keep-alive timer (0 seconds) expired!
[247459.930294] nvmet: ctrl 1 fatal error occurred!
Avoid this by not queuing delayed keep-alive if it is disabled when
keep-alive command is received from the admin queue.
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Tested-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Adding entry for dev_attr_fast_io_fail_tmo to avoid the kernel crash
while reading and writing the fast_io_fail_tmo.
Fixes: 09fbed6363 (nvme: export fast_io_fail_tmo to sysfs)
Signed-off-by: Gopal Tiwari <gtiwari@redhat.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of failing to scan the namespace entirely when unsupported
features are detected, just mark the gendisk hidden but allow other
access like the upcoming per-namespace character device.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
These will be reused for the per-namespace character devices.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Move the multipath block_device_operations to multipath.c, where they
belong.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Split out the ioctl code from core.c into a new file. Also update
copyrights while we're at it.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Don't bother to look up a namespace just to drop if after retreiving the
controller for the multipath case. Just look up a live controller for
the subsystem directly.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Only use the existing ioctl handler for the multipath case, and add a
simpler one that reverts to the pre-multipath case for not shared
use case.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Don't bother defining a separate compat_ioctl handler, and just handle
the NVME_IOCTL_SUBMIT_IO32 case inline. Also only defined it for those
ABIs (currently just i386 vs x86_64) that are affected.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Factor out a helper for the namespace based ioctls.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Pass the proper user pointer instead of the not all that useful integer
representation.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Return false from nvme_set_disk_name and let the caller set the
non-multipath name instead of duplicating the naming information in two
places. Also remove the pointless local variables for the disk name
and flags and the not needed ctrl argument.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Move the multipath gendisk out of #ifdef CONFIG_NVME_MULTIPATH and add
a new nvme_ns_head_multipath that uses it to check if a ns_head has
a multipath device associated with it.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
[hch: added the IS_ENABLED, converted a few existing users]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
There is a single trailing whitespace in core.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a single trailing whitespace in multipath.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a single trailing whitespace in pci.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the module parameter description for sgl_threshold,
a value of 0 means that SGLs are disabled.
If SGLs are disabled, we should respect that, even for the case
where the request is made up of a single physical segment.
Fixes: 297910571f ("nvme-pci: optimize mapping single segment requests using SGLs")
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a spelling mistake in a pr_err error message. Fix it.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Once a host is already created, avoid allocate additional hostports that
will be thrown away. add an helper function to handle host search.
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Amit Engel <amit.engel@dell.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case there is an io that contains inline data and it goes to
parsing error flow, command response will free command and iov
before clearing the data on the socket buffer.
This will delay the command response until receive flow is completed.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Signed-off-by: Elad Grupi <elad.grupi@dell.com>
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
list_sort() internally casts the comparison function passed to it
to a different type with constant struct list_head pointers, and
uses this pointer to call the functions, which trips indirect call
Control-Flow Integrity (CFI) checking.
Instead of removing the consts, this change defines the
list_cmp_func_t type and changes the comparison function types of
all list_sort() callers to use const pointers, thus avoiding type
mismatches.
Suggested-by: Nick Desaulniers <ndesaulniers@google.com>
Signed-off-by: Sami Tolvanen <samitolvanen@google.com>
Reviewed-by: Nick Desaulniers <ndesaulniers@google.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Kees Cook <keescook@chromium.org>
Tested-by: Nick Desaulniers <ndesaulniers@google.com>
Tested-by: Nathan Chancellor <nathan@kernel.org>
Signed-off-by: Kees Cook <keescook@chromium.org>
Link: https://lore.kernel.org/r/20210408182843.1754385-10-samitolvanen@google.com
Instead of overloading the passthrough fast path with the deprecated
block layer bounce buffering let the users that combine an old
undermaintained driver with a highmem system pay the price by always
falling back to copies in that case.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Link: https://lore.kernel.org/r/20210331073001.46776-9-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Instead of triggering an integer overflow and undefined behavior if MDTS is
large, set max_hw_sectors to UINT_MAX.
Signed-off-by: Bart Van Assche <bvanassche@acm.org>
Reviewed-by: Keith Busch <kbusch@kernel.org>
[hch: rebased to account for the new nvme_mps_to_sectors helper]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commands that access LBA contents without a data transfer between the
host historically have not had a spec defined upper limit. The driver
set the queue constraints for such commands to the max data transfer
size just to be safe, but this artificial constraint frequently limits
devices below their capabilities.
The NVMe Workgroup ratified TP4040 defines how a controller may
advertise their non-MDTS limits. Use these if provided and default to
the current constraints if not. Since the Dataset Management command
limits are defined in logical blocks, but without a namespace to tell us
the logical block size, the code defaults to the safe 512b size.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a passthru command targets a specific namespace, the ns parameter to
nvme_user_cmd()/nvme_user_cmd64() is set. However, there is currently no
validation that the nsid specified in the passthru command targets the
namespace/nsid represented by the block device that the ioctl was
performed on.
Add a check that validates that the nsid in the passthru command matches
that of the supplied namespace.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Reviewed-by: Javier González <javier@javigon.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If ANA is enabled but no ANA group descriptor is found when creating
a new namespace the ANA log is most likely out of date, so trigger
a re-read. The namespace will be tagged with the NS_ANA_PENDING flag
to exclude it from path selection until the ANA log has been re-read.
Fixes: 32acab3181 ("nvme: implement multipath access to nvme subsystems")
Reported-by: Martin George <marting@netapp.com>
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commit 8c4dfea97f ("nvme-fabrics: reject I/O to offline device")
introduced fast_io_fail_tmo but didn't export the value to sysfs. The
value can be set during the 'nvme connect'. Export the timeout value
to user space via sysfs to allow runtime configuration.
Cc: Victor Gladkov <Victor.Gladkov@kioxia.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Ewan D. Milne <emilne@redhat.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhaani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If there is an error we will leave the function early. So there
is no need for an else. Remove it.
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
sysfs_emit is the recommended API to use for formatting strings to be
returned to user space. It is equivalent to scnprintf and aware of the
PAGE_SIZE buffer size.
Suggested-by: Chaitanya Kulkarni <Chaitanya.Kulkarni@wdc.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
SGLs support is mandatory for NVMe/FC, make sure that the target is
aligned to the specification.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
SGLs support is mandatory for NVMe/tcp, make sure that the target is
aligned to the specification.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add 'idle_poll_period_usecs' option used by io_work() to support
network devices enabled with advanced interrupt moderation
supporting a relaxed interrupt model. It was discovered that
such a NIC used on the target was unable to support initiator
connection establishment, caused by the existing io_work()
flow that immediately exits after a loop with no activity and
does not re-queue itself.
With this new option a queue is assigned a period of time
that no activity must occur in order to become 'idle'. Until
the queue is idle the work item is requeued.
The new module option is defined as changeable making it
flexible for testing purposes.
The pre-existing legacy behavior is preserved when no module option
for idle_poll_period_usecs is specified.
Signed-off-by: Mark Wunderlich <mark.wunderlich@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The TCP stack can run from process context for a long time
so we should disable BH here.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Return NVME_SC_INVALID_FIELD from discovery controller like normal
controller when executing identify or get log page command.
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We don't need to repeatedly spam the kernel logs with the same warning
about unhandled passthrough IO effects. Just one warning is sufficient
to observe this condition occurs.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
All nvme transport drivers preallocate an nvme command for each request.
Assume to use that command for nvme_setup_cmd() instead of requiring
drivers pass a pointer to it. All nvme drivers must initialize the
generic nvme_request 'cmd' to point to the transport's preallocated
nvme_command.
The generic nvme_request cmd pointer had previously been used only as a
temporary copy for passthrough commands. Since it now points to the
command that gets dispatched, passthrough commands must directly set it
up prior to executing the request.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Jens Axboe <axboe@kernel.dk>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Except for pci, all the nvme transport drivers allocate a command within
the driver's pdu. Align pci with everyone else by allocating the nvme
command within pci's pdu and replace the .queue_rq() stack variable with
this.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Jens Axboe <axboe@kernel.dk>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVM specifications, the model number size should be
40 bytes (bytes 63:24 of the Identify Controller data structure).
Therefore, any attempt to store a value into model_number which
exceeds 40 bytes should return an error.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_ctrl_find_get() accepts out pointer to nvmet_ctrl
structure. This function returns the same error value from two places
that is :- NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR.
Move this to the caller so we can change the return type to nvmet_ctrl.
Now that we can changed the return type, instead of taking out pointer
to the nvmet_ctrl structure remove that function parameter and return
the valid nvmet_ctrl pointer on success and NULL on failure.
Also, add and rename the goto labels for more readability with comments.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add minimum description of the hosthandle parameter for
nvmet_fc_rcv_ls_req() so that we can get rid of the following warning.
drivers/nvme//target/fc.c:2009: warning: Function parameter or member 'hosthandle' not described in 'nvmet_fc_rcv_ls_req
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The nvme_fc_rcv_ls_req() function has first argument as pointer to
remoteport named portprt, but in the documentation comment that is name
is used as remoteport. Fix that to get rid if the compilation warning.
drivers/nvme//host/fc.c:1724: warning: Function parameter or member 'portptr' not described in 'nvme_fc_rcv_ls_req'
drivers/nvme//host/fc.c:1724: warning: Excess function parameter 'remoteport' description in 'nvme_fc_rcv_ls_req'
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add a new line in functions nvme_pr_preempt(), nvme_pr_clear(), and
nvme_pr_release() after variable declaration which follows the rest of
the code in the nvme/host/core.c.
No functional change(s) in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_clear_request() has a check for flag REQ_DONTPREP and it is called
from nvme_init_request() and nvme_setuo_cmd().
The function nvme_init_request() is called from nvme_alloc_request()
and nvme_alloc_request_qid(). From these two callers new request is
allocated everytime. For newly allocated request RQF_DONTPREP is never
set. Since after getting a tag, block layer sets the req->rq_flags == 0
and never sets the REQ_DONTPREP when returning the request :-
nvme_alloc_request()
blk_mq_alloc_request()
blk_mq_rq_ctx_init()
rq->rq_flags = 0 <----
nvme_alloc_request_qid()
blk_mq_alloc_request_hctx()
blk_mq_rq_ctx_init()
rq->rq_flags = 0 <----
The block layer does set req->rq_flags but REQ_DONTPREP is not one of
them and that is set by the driver.
That means we can unconditinally set the REQ_DONTPREP value to the
rq->rq_flags when nvme_init_request()->nvme_clear_request() is called
from above two callers.
Move the check for REQ_DONTPREP from nvme_clear_nvme_request() into
nvme_setup_cmd().
This is needed since nvme_alloc_request() now gets called from fast
path when NVMeOF target is configured with passthru backend to avoid
unnecessary checks in the fast path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Since nvmet_setup_passthru() function falls in fast path when called
from the NVMeOF passthru backend, make it inline.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvme_init_ctrl_finish() (formerly nvme_init_identify()) has
grown over the period of time about ~200 lines given the size of nvme id
ctrl data structure.
Move the nvme_id_ctrl data structure related initilzation into helper
nvme_init_identify() and call it from nvme_init_ctrl_finish().
When we move the code into nvme_init_identify() change the local
variable i from int to unsigned int and remove the duplicate kfree()
after nvme_mpath_init() and jump to the label out_free if
nvme_mpath_ini() fails.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This is a prep patch so that we can move the identify data structure
related code initialization from nvme_init_identify() into a helper.
Rename the function nvmet_init_identify() to nvmet_init_ctrl_finish().
Next patch will move the nvme_id_ctrl related initialization from newly
renamed function nvme_init_ctrl_finish() into the nvme_init_identify()
helper.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For passthrough I/O commands, effects are usually to be zero.
nvme_passthrough_end() does three checks in futility for this case.
Bail out of function-call/checks.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the proper macro instead of hard-coded value.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of the using the whitespaces use tab spacing in the
nvmet_execute_identify_ns().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_check_ctrl_status() cmd can be derived from nvmet_req. Remove
the local variable cmd in the nvmet_check_ctrl_status() and function
parameter cmd for nvmet_check_ctrl_status(). Derive the cmd value from
req parameter in the nvmet_check_ctrl_status().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of updating the error log page in the caller of the
nvmet_alloc_ctrt() update the error log page in the nvmet_alloc_ctrl().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the function nvmet_alloc_ctrl() we assign status value before we
call nvmet_fine_get_subsys() to:
status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
After we successfully find the subsystem we again set the status value
to:
status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
Remove the duplicate status assignment value.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Get rid of a local variable that is not needed and just return the
status directly.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The barriers were added to the nvme_irq() in commit 3a7afd8ee4
("nvme-pci: remove the CQ lock for interrupt driven queues") to prevent
compiler from doing memory optimization for the variabes that were
protected previously by spinlock in nvme_irq() at completion queue
processing and with queue head check condition.
The variable nvmeq->last_cq_head from those checks was removed in the
commit f6c4d97b0d ("nvme/pci: Remove last_cq_head") that was not
allwing poll queues from mistakenly triggering the spurious interrupt
detection.
Remove the barriers which were protecting the updates to the variables.
Reported-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When data digest is enabled we should unmap pdu iovec before handling
the data digest pdu.
Signed-off-by: Elad Grupi <elad.grupi@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
From the base spec, Figure 78:
"Controller Configuration, these fields are defined as parameters to
configure an "I/O Controller (IOC)" and not to configure a "Discovery
Controller (DC).
...
If the controller does not support I/O queues, then this field shall
be read-only with a value of 0h
Just perform this check for I/O controllers.
Fixes: a07b4970f4 ("nvmet: add a generic NVMe target")
Reported-by: Belanger, Martin <Martin.Belanger@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only setup io queues for nvme controllers, and it makes absolutely no
sense to allow a controller (re)connect without any I/O queues. If we
happen to fail setting the queue count for any reason, we should not allow
this to be a successful reconnect as I/O has no chance in going through.
Instead just fail and schedule another reconnect.
Reported-by: Chao Leng <lengchao@huawei.com>
Fixes: 7110230719 ("nvme-rdma: add a NVMe over Fabrics RDMA host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only setup io queues for nvme controllers, and it makes absolutely no
sense to allow a controller (re)connect without any I/O queues. If we
happen to fail setting the queue count for any reason, we should not
allow this to be a successful reconnect as I/O has no chance in going
through. Instead just fail and schedule another reconnect.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For our pure advisory use-case, we only rely on this call as a hint, so
fix the warning complaints of using the smp_processor_id variants with
preemption enabled.
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Fixes: ada8317721 ("nvme-tcp: Fix warning with CONFIG_DEBUG_PREEMPT")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Tested-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When the controller sends us a 0-length r2t PDU we should not attempt to
try to set up a h2cdata PDU but rather conclude that this is a buggy
controller (forward progress is not possible) and simply fail it
immediately.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Reported-by: Belanger, Martin <Martin.Belanger@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We voluntarily limit the Write Zeroes sizes to the MDTS value provided by
the hardware, but currently get the units wrong, so fix that.
Fixes: 6e02318eae ("nvme: add support for the Write Zeroes command")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Tested-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
To avoid an error recovery deadlock where the keep alive work is waiting
for a request and thus can't be flushed to make progress for tearing down
the controller. Also print the error code returned from
blk_mq_alloc_request to help debugging any future issues in this code.
Based on an earlier patch from Hannes Reinecke <hare@suse.de>.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Merge nvme_keep_alive into its only caller to prepare for additional
changes to this code.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Fabrics drivers currently reserve two tags on the admin queue. But
given that the connect command is only run on a freshly created queue
or after all commands have been force aborted we only need to reserve
a single tag.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
ns can be NULL at this point, and my move of the check from
the original patch by Chaitanya broke this.
Fixes: 0ec84df495 ("nvme-core: check ctrl css before setting up zns")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
- one more quirk (Dmitry Monakhov)
- fix max_zone_append_sectors initialization (Chaitanya Kulkarni)
- nvme-fc reset/create race fix (James Smart)
- fix status code on aborts/resets (Hannes Reinecke)
- fix the CSS check for ZNS namespaces (Chaitanya Kulkarni)
- fix a use after free in a debug printk in nvme-rdma (Lv Yunlong)
-----BEGIN PGP SIGNATURE-----
iQI/BAABCgApFiEEgdbnc3r/njty3Iq9D55TZVIEUYMFAmBLMlwLHGhjaEBsc3Qu
ZGUACgkQD55TZVIEUYNVLA//aay9+Jq/BTwXG69249PshsvGpw5EVpaNp5YIwxyM
ehC7AW5vm+1wg3b8X1O+sRhJ+PSKs3hbzUxoVWsGwj4RxJB0OPRnthjtcaGz2Ly3
5q/IGlA6Qxk0cHLRqTg+l3n4d1ctPpt+wS2IcTJpgh8Vmqj+/H3+jD26UjhvLySr
I9zgtl27STC8nwQwWYOXvbLql3eRzilZNd4qydnZIlcj/+CW3MGehiFlaVKsUQP1
FJwx8LVHNU3V6n21eT99Xa9Lu/vWRjPQEyEBLV9iZ/dD2JVS1Q4TI/hwtTjFLZvi
CVw1uu8HfSlYE/lA4wclPfljdZLUt2chjVG5S/lqJJmmoy7J6xf4b0hNI2yLGjft
yKZB+vi+nKKoj3OLiy+LpopXSb23BMDlis1EqL/rXtU1JXsonDcsTAdscACvTHTL
2aVbyHQ2hvNOs6L7GkHGEwu7nNE31tG7+DOXnjHwfq3j2mTnHu2AniAF9llG1NuC
nbIQZQxRDdakknJsZU8YWG3rkOFUDLs9z2V3O5bs8KlTgYTkCut0Vtgdx2vZ2iVF
jTmbEuFyK6pcWgFEFk6IP4LawJPNpozo8NQZGMUOp3ym8CXm/NHuxj1R3w8LcAH6
OvmQWo6AcUNyaXNhVNPADqmnY2ZDjYC6/KWoMrg/YESCYXqfpMvXfArVbyYoU9yD
61U=
=LkdO
-----END PGP SIGNATURE-----
Merge tag 'nvme-5.12-2021-03-12' of git://git.infradead.org/nvme into block-5.12
Pull NVMe fixes from Christoph:
"nvme fixes for 5.12:
- one more quirk (Dmitry Monakhov)
- fix max_zone_append_sectors initialization (Chaitanya Kulkarni)
- nvme-fc reset/create race fix (James Smart)
- fix status code on aborts/resets (Hannes Reinecke)
- fix the CSS check for ZNS namespaces (Chaitanya Kulkarni)
- fix a use after free in a debug printk in nvme-rdma (Lv Yunlong)"
* tag 'nvme-5.12-2021-03-12' of git://git.infradead.org/nvme:
nvme-pci: add the DISABLE_WRITE_ZEROES quirk for a Samsung PM1725a
nvme-rdma: Fix a use after free in nvmet_rdma_write_data_done
nvme-core: check ctrl css before setting up zns
nvme-fc: fix racing controller reset and create association
nvme-fc: return NVME_SC_HOST_ABORTED_CMD when a command has been aborted
nvme-fc: set NVME_REQ_CANCELLED in nvme_fc_terminate_exchange()
nvme: add NVME_REQ_CANCELLED flag in nvme_cancel_request()
nvme: simplify error logic in nvme_validate_ns()
nvme: set max_zone_append_sectors nvme_revalidate_zones
Ever since the addition of multipage bio_vecs BIO_MAX_PAGES has been
horribly confusingly misnamed. Rename it to BIO_MAX_VECS to stop
confusing users of the bio API.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Matthew Wilcox (Oracle) <willy@infradead.org>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Link: https://lore.kernel.org/r/20210311110137.1132391-2-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
In nvmet_rdma_write_data_done, rsp is recoverd by wc->wr_cqe and freed by
nvmet_rdma_release_rsp(). But after that, pr_info() used the freed
chunk's member object and could leak the freed chunk address with
wc->wr_cqe by computing the offset.
Signed-off-by: Lv Yunlong <lyl2019@mail.ustc.edu.cn>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Ensure multiple Command Sets are supported before starting to setup a
ZNS namespace.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
[hch: move the check around a bit]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Recent patch to prevent calling __nvme_fc_abort_outstanding_ios in
interrupt context results in a possible race condition. A controller
reset results in errored io completions, which schedules error
work. The change of error work to a work element allows it to fire
after the ctrl state transition to NVME_CTRL_CONNECTING, causing
any outstanding io (used to initialize the controller) to fail and
cause problems for connect_work.
Add a state check to only schedule error work if not in the RESETTING
state.
Fixes: 19fce0470f ("nvme-fc: avoid calling _nvme_fc_abort_outstanding_ios from interrupt context")
Signed-off-by: Nigel Kirkland <nkirkland2304@gmail.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a command has been aborted we should return NVME_SC_HOST_ABORTED_CMD
to be consistent with the other transports.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_fc_terminate_exchange() is being called when exchanges are
being deleted, and as such we should be setting the NVME_REQ_CANCELLED
flag to have identical behaviour on all transports.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVME_REQ_CANCELLED is translated into -EINTR in nvme_submit_sync_cmd(),
so we should be setting this flags during nvme_cancel_request() to
ensure that the callers to nvme_submit_sync_cmd() will get the correct
error code when the controller is reset.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only should remove namespaces when we get fatal error back from
the device or when the namespace IDs have changed.
So instead of painfully masking out error numbers which might indicate
that the error should be ignored we could use an NVME status code
to indicated when the namespace should be removed.
That simplifies the final logic and makes it less error-prone.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case we have already established connection to nvmf target, it
shouldn't be allowed to change the model_number. E.g. if someone will
identify ctrl and get model_number of "my_model" later on will change
the model_numbel via configfs to "my_new_model" this will break the NVMe
specification for "Get Log Page – Persistent Event Log" that refers to
Model Number as: "This field contains the same value as reported in the
Model Number field of the Identify Controller data structure, bytes
63:24."
Although it doesn't mentioned explicitly that this field can't be
changed, we can assume it.
So allow setting this field only once: using configfs or in the first
identify ctrl operation.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Currently kato is initialized to NVME_DEFAULT_KATO for both
discovery & i/o controllers. This is a problem specifically
for non-persistent discovery controllers since it always ends
up with a non-zero kato value. Fix this by initializing kato
to zero instead, and ensuring various controllers are assigned
appropriate kato values as follows:
non-persistent controllers - kato set to zero
persistent controllers - kato set to NVMF_DEV_DISC_TMO
(or any positive int via nvme-cli)
i/o controllers - kato set to NVME_DEFAULT_KATO
(or any positive int via nvme-cli)
Signed-off-by: Martin George <marting@netapp.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The hwmon pointer wont be NULL if the registration fails. Though the
exit code path will assign it to ctrl->hwmon_device. Later
nvme_hwmon_exit() will try to free the invalid pointer. Avoid this by
returning the error code from hwmon_device_register_with_info().
Fixes: ed7770f662 ("nvme/hwmon: rework to avoid devm allocation")
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add the NVME_QUIRK_NO_NS_DESC_LIST and NVME_QUIRK_IGNORE_DEV_SUBNQN
quirks for this buggy device.
Reported and tested in https://bugs.mageia.org/show_bug.cgi?id=28417
Signed-off-by: Pascal Terjan <pterjan@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
My 2TB SKC2000 showed the exact same symptoms that were provided
in 538e4a8c57 ("nvme-pci: avoid the deepest sleep state on
Kingston A2000 SSDs"), i.e. a complete NVME lockup that needed
cold boot to get it back.
According to some sources, the A2000 is simply a rebadged
SKC2000 with a slightly optimized firmware.
Adding the SKC2000 PCI ID to the quirk list with the same workaround
as the A2000 made my laptop survive a 5 hours long Yocto bootstrap
buildfest which reliably triggered the SSD lockup previously.
Signed-off-by: Zoltán Böszörményi <zboszor@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
-----BEGIN PGP SIGNATURE-----
iQJEBAABCAAuFiEEwPw5LcreJtl1+l5K99NY+ylx4KYFAmA6njIQHGF4Ym9lQGtl
cm5lbC5kawAKCRD301j7KXHgprolD/9zWti9LsZvA7yE+PhVwrwF3CsNzLfQlClw
99HaA7HxtAc/VLJrnD/SubhCAPdBC5B2xPv6faajdwF2iUR3Rr1Uc93CQ3uP2KKq
kvm6ALTpzPTMI6YSABhY74sg9BkkoDbMo54JQYVQPleiE+5eDLbuFZck6ObfUHyY
a4aaImlndWp/t14GzrClL4hucF+5KJy846P+QCVclkh0yl8xSsqZ5LIFU7tu3iQb
HpZ5HKLT/2ma/EOr3wknnsIe97AUZQU0q5aMparhYlm+qR511eop3QXx850FL/oC
tEGceKLij6qazmkiocKVzML8Fs+Y9/a4vCMjLCScWJmzDlmKdlH2uudeahN6b9Hm
15qRQHOjl1Hc2bdr5ZVn87nq9RWhSm18C+SRMwOKHCOnEhwxqM3RjRfAgj4BJ6QB
PFbFqdY+8Y1YLPFmn9hph72ePaEcN4L2IXW6TI/WX8mot8ODAnkq9Hr38dKwzO+i
0mon6DVyJKKho6XwvVu5IYurkR2beQprjeVUxwZjjT6DxUgsc+J6itK5LDHFSkeZ
qZlXn5Di8MkiXg0DFJYDQiFXnO0Z5GlRWOGPVfBaOr3x+1dqzDdHGw4oz1oGqvnr
GNNYCsYIpDGm7eauX5lqL5MUFpjqRCceXy5JSHPhnWWw617nYkr4H9jdsV9HiTX1
tQFx05QW3w==
=ccMs
-----END PGP SIGNATURE-----
Merge tag 'block-5.12-2021-02-27' of git://git.kernel.dk/linux-block
Pull more block updates from Jens Axboe:
"A few stragglers (and one due to me missing it originally), and fixes
for changes in this merge window mostly. In particular:
- blktrace cleanups (Chaitanya, Greg)
- Kill dead blk_pm_* functions (Bart)
- Fixes for the bio alloc changes (Christoph)
- Fix for the partition changes (Christoph, Ming)
- Fix for turning off iopoll with polled IO inflight (Jeffle)
- nbd disconnect fix (Josef)
- loop fsync error fix (Mauricio)
- kyber update depth fix (Yang)
- max_sectors alignment fix (Mikulas)
- Add bio_max_segs helper (Matthew)"
* tag 'block-5.12-2021-02-27' of git://git.kernel.dk/linux-block: (21 commits)
block: Add bio_max_segs
blktrace: fix documentation for blk_fill_rw()
block: memory allocations in bounce_clone_bio must not fail
block: remove the gfp_mask argument to bounce_clone_bio
block: fix bounce_clone_bio for passthrough bios
block-crypto-fallback: use a bio_set for splitting bios
block: fix logging on capacity change
blk-settings: align max_sectors on "logical_block_size" boundary
block: reopen the device in blkdev_reread_part
block: don't skip empty device in in disk_uevent
blktrace: remove debugfs file dentries from struct blk_trace
nbd: handle device refs for DESTROY_ON_DISCONNECT properly
kyber: introduce kyber_depth_updated()
loop: fix I/O error on fsync() in detached loop devices
block: fix potential IO hang when turning off io_poll
block: get rid of the trace rq insert wrapper
blktrace: fix blk_rq_merge documentation
blktrace: fix blk_rq_issue documentation
blktrace: add blk_fill_rwbs documentation comment
block: remove superfluous param in blk_fill_rwbs()
...
It's often inconvenient to use BIO_MAX_PAGES due to min() requiring the
sign to be the same. Introduce bio_max_segs() and change BIO_MAX_PAGES to
be unsigned to make it easier for the users.
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Matthew Wilcox (Oracle) <willy@infradead.org>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Pull swiotlb updates from Konrad Rzeszutek Wilk:
"Two memory encryption related patches (SWIOTLB is enabled by default
for AMD-SEV):
- Add support for alignment so that NVME can properly work
- Keep track of requested DMA buffers length, as underlaying hardware
devices can trip SWIOTLB to bounce too much and crash the kernel
And a tiny fix to use proper APIs in drivers"
* 'stable/for-linus-5.12' of git://git.kernel.org/pub/scm/linux/kernel/git/konrad/swiotlb:
swiotlb: Validate bounce size in the sync/unmap path
nvme-pci: set min_align_mask
swiotlb: respect min_align_mask
swiotlb: don't modify orig_addr in swiotlb_tbl_sync_single
swiotlb: refactor swiotlb_tbl_map_single
swiotlb: clean up swiotlb_tbl_unmap_single
swiotlb: factor out a nr_slots helper
swiotlb: factor out an io_tlb_offset helper
swiotlb: add a IO_TLB_SIZE define
driver core: add a min_align_mask field to struct device_dma_parameters
sdhci: stop poking into swiotlb internals
The PRP addressing scheme requires all PRP entries except for the
first one to have a zero offset into the NVMe controller pages (which
can be different from the Linux PAGE_SIZE). Use the min_align_mask
device parameter to ensure that swiotlb does not change the address
of the buffer modulo the device page size to ensure that the PRPs
won't be malformed.
Signed-off-by: Jianxiong Gao <jxgao@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Tested-by: Jianxiong Gao <jxgao@google.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
-----BEGIN PGP SIGNATURE-----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=vx6U
-----END PGP SIGNATURE-----
Merge tag 'for-5.12/drivers-2021-02-17' of git://git.kernel.dk/linux-block
Pull block driver updates from Jens Axboe:
- Remove the skd driver. It's been EOL for a long time (Damien)
- NVMe pull requests
- fix multipath handling of ->queue_rq errors (Chao Leng)
- nvmet cleanups (Chaitanya Kulkarni)
- add a quirk for buggy Amazon controller (Filippo Sironi)
- avoid devm allocations in nvme-hwmon that don't interact well
with fabrics (Hannes Reinecke)
- sysfs cleanups (Jiapeng Chong)
- fix nr_zones for multipath (Keith Busch)
- nvme-tcp crash fix for no-data commands (Sagi Grimberg)
- nvmet-tcp fixes (Sagi Grimberg)
- add a missing __rcu annotation (Christoph)
- failed reconnect fixes (Chao Leng)
- various tracing improvements (Michal Krakowiak, Johannes
Thumshirn)
- switch the nvmet-fc assoc_list to use RCU protection (Leonid
Ravich)
- resync the status codes with the latest spec (Max Gurtovoy)
- minor nvme-tcp improvements (Sagi Grimberg)
- various cleanups (Rikard Falkeborn, Minwoo Im, Chaitanya
Kulkarni, Israel Rukshin)
- Floppy O_NDELAY fix (Denis)
- MD pull request
- raid5 chunk_sectors fix (Guoqing)
- Use lore links (Kees)
- Use DEFINE_SHOW_ATTRIBUTE for nbd (Liao)
- loop lock scaling (Pavel)
- mtip32xx PCI fixes (Bjorn)
- bcache fixes (Kai, Dongdong)
- Misc fixes (Tian, Yang, Guoqing, Joe, Andy)
* tag 'for-5.12/drivers-2021-02-17' of git://git.kernel.dk/linux-block: (64 commits)
lightnvm: pblk: Replace guid_copy() with export_guid()/import_guid()
lightnvm: fix unnecessary NULL check warnings
nvme-tcp: fix crash triggered with a dataless request submission
block: Replace lkml.org links with lore
nbd: Convert to DEFINE_SHOW_ATTRIBUTE
nvme: add 48-bit DMA address quirk for Amazon NVMe controllers
nvme-hwmon: rework to avoid devm allocation
nvmet: remove else at the end of the function
nvmet: add nvmet_req_subsys() helper
nvmet: use min of device_path and disk len
nvmet: use invalid cmd opcode helper
nvmet: use invalid cmd opcode helper
nvmet: add helper to report invalid opcode
nvmet: remove extra variable in id-ns handler
nvmet: make nvmet_find_namespace() req based
nvmet: return uniform error for invalid ns
nvmet: set status to 0 in case for invalid nsid
nvmet-fc: add a missing __rcu annotation to nvmet_fc_tgt_assoc.queues
nvme-multipath: set nr_zones for zoned namespaces
nvmet-tcp: fix potential race of tcp socket closing accept_work
...
-----BEGIN PGP SIGNATURE-----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=os1E
-----END PGP SIGNATURE-----
Merge tag 'for-5.12/block-2021-02-17' of git://git.kernel.dk/linux-block
Pull core block updates from Jens Axboe:
"Another nice round of removing more code than what is added, mostly
due to Christoph's relentless pursuit of tech debt removal/cleanups.
This pull request contains:
- Two series of BFQ improvements (Paolo, Jan, Jia)
- Block iov_iter improvements (Pavel)
- bsg error path fix (Pan)
- blk-mq scheduler improvements (Jan)
- -EBUSY discard fix (Jan)
- bvec allocation improvements (Ming, Christoph)
- bio allocation and init improvements (Christoph)
- Store bdev pointer in bio instead of gendisk + partno (Christoph)
- Block trace point cleanups (Christoph)
- hard read-only vs read-only split (Christoph)
- Block based swap cleanups (Christoph)
- Zoned write granularity support (Damien)
- Various fixes/tweaks (Chunguang, Guoqing, Lei, Lukas, Huhai)"
* tag 'for-5.12/block-2021-02-17' of git://git.kernel.dk/linux-block: (104 commits)
mm: simplify swapdev_block
sd_zbc: clear zone resources for non-zoned case
block: introduce blk_queue_clear_zone_settings()
zonefs: use zone write granularity as block size
block: introduce zone_write_granularity limit
block: use blk_queue_set_zoned in add_partition()
nullb: use blk_queue_set_zoned() to setup zoned devices
nvme: cleanup zone information initialization
block: document zone_append_max_bytes attribute
block: use bi_max_vecs to find the bvec pool
md/raid10: remove dead code in reshape_request
block: mark the bio as cloned in bio_iov_bvec_set
block: set BIO_NO_PAGE_REF in bio_iov_bvec_set
block: remove a layer of indentation in bio_iov_iter_get_pages
block: turn the nr_iovecs argument to bio_alloc* into an unsigned short
block: remove the 1 and 4 vec bvec_slabs entries
block: streamline bvec_alloc
block: factor out a bvec_alloc_gfp helper
block: move struct biovec_slab to bio.c
block: reuse BIO_INLINE_VECS for integrity bvecs
...
Some Amazon NVMe controllers do not follow the NVMe specification
and are limited to 48-bit DMA addresses. Add a quirk to force
bounce buffering if needed and limit the IOVA allocation for these
devices.
This affects all current Amazon NVMe controllers that expose EBS
volumes (0x0061, 0x0065, 0x8061) and local instance storage
(0xcd00, 0xcd01, 0xcd02).
Signed-off-by: Filippo Sironi <sironi@amazon.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The original design to use device-managed resource allocation
doesn't really work as the NVMe controller has a vastly different
lifetime than the hwmon sysfs attributes, causing warning about
duplicate sysfs entries upon reconnection.
This patch reworks the hwmon allocation to avoid device-managed
resource allocation, and uses the NVMe controller as parent for
the sysfs attributes.
Cc: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Hannes Reinecke <hare@suse.de>
Tested-by: Enzo Matsumiya <ematsumiya@suse.de>
Tested-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_parse_io_cmd() returns value from
nvmet_file_parse_io_cmd() or nvmet_bdev_parse_io_cmd() based on which
backend is set for the request. Remove the else and just return the
value from nvmet_bdev_parse_io_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Just like what we have to get the passthru ctrl from the req, add an
helper to get the subsystem associated with the nvmet_req() instead
of open coding the chain of structures.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In function __assign_req_name() instead of using the DEVICE_NAME_LEN in
strncpy() use min of DISK_NAME_LEN and strlen(req->ns->device_path).
This is needed to turn off the following warnings:-
In file included from drivers/nvme/target/core.c:14:
In function ‘__assign_req_name’,
inlined from ‘trace_event_raw_event_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘perf_trace_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘perf_trace_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘trace_event_raw_event_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Use the previously introduced helper in the passthru backend to make the
error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Use the previously introduced helper in file backend to reduce the
duplicate code and make the error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Add an helper and use it in block device backend to keep the code
and error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_execute_identify_ns() local variable ctrl is accessed only in
one place, remove that and directly use it from nvmet_req->sq->ctrl.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The six callers of nvmet_find_namespace() duplicate the error log page
update and status setting code for each call on failure.
All callers are nvmet requests based functions, so we can pass req
to the nvmet_find_namesapce() & derive ctrl from req, that'll allow us
to update the error log page in nvmet_find_namespace(). Now that we
pass the request we can also get rid of the local variable in
nvmet_find_namespace() and use the req->ns and return the error code.
Replace the ctrl parameter with nvmet_req for nvmet_find_namespace(),
centralize the error log page update for non allocated namesapces, and
return uniform error for non-allocated namespace.
The nvmet_find_namespace() takes nsid parameter which is from NVMe
commands structures such as get_log_page, identify, rw and common. All
these commands have same offset for the nsid field.
Derive nsid from req->cmd->common.nsid) & remove the extra parameter
from the nvmet_find_namespace().
Lastly now we associate the ns to the req parameter that we pass to the
nvmet_find_namespace(), rename nvmet_find_namespace() to
nvmet_req_find_ns().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For nvmet_find_namespace() error case we have inconsistent error code
mapping in the function nvmet_get_smart_log_nsid() and
nvmet_set_feat_write_protect().
There is no point in retrying for the invalid namesapce from the host
side. Set the error code to the NVME_SC_INVALID_NS | NVME_SC_DNR which
matches what we have in nvmet_execute_identify_desclist().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For unallocated namespace in nvmet_execute_identify_ns() don't set the
status to NVME_SC_INVALID_NS, set it to zero.
Fixes: bffcd50778 ("nvmet: set right status on error in id-ns handler")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Make sparse happy after the recent conversion to RCU lookups.
Fixes: 4e2f02bf77 ("nvmet-fc: use RCU proctection for assoc_list")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
The bio based drivers only require the request_queue's nr_zones is set,
so set this field in the head if the namespace path is zoned.
Fixes: 240e6ee272 ("nvme: support for zoned namespaces")
Reported-by: Minwoo Im <minwoo.im.dev@gmail.com>
Cc: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When we accept a TCP connection and allocate an nvmet-tcp queue we should
make sure not to fully establish it or reference it as the connection may
be already closing, which triggers queue release work, which does not
fence against queue establishment.
In order to address such a race, we make sure to check the sk_state and
contain the queue reference to be done underneath the sk_callback_lock
such that the queue release work correctly fences against it.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Elad Grupi <elad.grupi@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a host sends multiple h2cdata PDUs for a single command, we
should verify the data digest calculation per PDU and not
per command.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Tested-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_rdma_post_send failing is a path related error and should bounce
to another path when using nvme-multipath. Call nvme_host_path_error
when nvme_rdma_post_send returns -EIO to ensure nvme_complete_rq gets
invoked to fail over to another path if there is one.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When reconnecting, the request may be completed with
NVME_SC_HOST_PATH_ERROR in nvmf_fail_nonready_command, which currently
set the state of the request to MQ_RQ_IN_FLIGHT before calling
nvme_complete_rq. When this happens for a request that is freed by
the caller, such as nvme_submit_user_cmd, in the worst case the request
could be completed again in tear down process.
Instead of calling blk_mq_start_request from nvmf_fail_nonready_command,
just use the new nvme_host_path_error helper to complete the command
without starting it.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When using nvme native multipathing, if a path related error occurs
during ->queue_rq, the request needs to be completed with
NVME_SC_HOST_PATH_ERROR so that the request can be failed over.
Introduce a helper to complete the command from ->queue_rq in a wait
that invokes nvme_complete_rq.
Signed-off-by: Chao Leng <lengchao@huawei.com>
[hch: renamed, added a return value to clean up the callers a bit]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Fix the following coccicheck warning:
./drivers/nvme/host/core.c:3580:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3570:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3560:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3526:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:2833:8-16: WARNING: use scnprintf or sprintf.
Reported-by: Abaci Robot<abaci@linux.alibaba.com>
Signed-off-by: Jiapeng Chong <jiapeng.chong@linux.alibaba.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For a zoned namespace, in nvme_update_ns_info(), call
nvme_update_zone_info() after executing nvme_update_disk_info() so that
the namespace queue logical and physical block size limits are set.
This allows setting the namespace queue max_zone_append_sectors limit
in nvme_update_zone_info() instead of nvme_revalidate_zones(),
simplifying this function. Also use blk_queue_set_zoned() to set the
namespace zoned model.
Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Johannes Thumshirn <johannes.thumshirn@edc.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
When the host sends multiple h2cdata PDUs, we keep track on
the receive progress and calculate the scatterlist index and
offsets.
The issue is that sg_offset should only be kept for the first
iov entry we map in the iovec as this is the difference between
our cursor and the sg entry offset itself.
In addition, the sg index was calculated wrong because we should
not round up when dividing the command byte offset with PAG_SIZE.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Tested-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Tested both with Corsairs firmware 11.3 and 13.0 for the Corsairs MP600
and both have the issue as reported by the kernel.
nvme nvme0: missing or invalid SUBNQN field.
Signed-off-by: Claus Stovgaard <claus.stovgaard@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.
Add sync queues and cancel suppend requests for reconnection error
handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A crash happens when inject failed reconnection.
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.
Add sync queues and cancel suppend requests for reconnection error
handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add nvme_cancel_tagset and nvme_cancel_admin_tagset for tear down and
reconnection error handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the extra space in the nvme_free_cels() when calling
xa_for_each loop which is not a common practice
(except drivers/infiniband/core/ not sure why).
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When support for the NVMe ZNS commands was merged, tracing of these has
been omitted.
Add nvme_cmd_zone_mgmt_send, nvme_cmd_zone_mgmt_recv as well as
nvme_cmd_zone_append to the nvme driver's tracing facility.
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add detailed parsing of format nvm admin command to make the
trace log more consistent and human-readable.
Signed-off-by: Michal Krakowiak <michal.krakowiak@intel.com>
Acked-by: Dan Williams <dan.j.williams@intel.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In this preparation patch, we add helpers to convert lbas to sectors &
sectors to lba. This is needed to eliminate code duplication in the ZBD
backend.
Use these helpers in the block device backend.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_ns() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_desclist() since req already has ns member that
can be reused, this also eliminates the explicit call to
nvmet_put_namespace() which is already present in the request
completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_get_smart_log_nsid() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Just for current code in nvme_cleanup_cmd(), we don't have to get
namespace instance, but we need controller instance.
Controller instance can be retrieved by namespace instance, but it can
be directly accessed by nvme_request instance from request.
ctrl = nvme_req(req)->ctrl;
We don't have to go around namespace instance from request instance
through gendisk.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>