Currently oscillator frequency is determined based on sysboot settings,
it may not be the case always. To determine it properly, efuse settings
also has to be read. CONTROL_STATUS register holds this information.
Bit 31: if 0, frequency to be determined based on sysboot
if 1, frequency to be determined based on efuse
Bit 29,30 - for efuse detection of frequency
Bit 22,23 - for sysboot detection of frequency
Add clock nodes (mux) to determine oscillator frequency as above.
Signed-off-by: Afzal Mohammed <afzal@ti.com>
Acked-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Sekhar Nori <nsekhar@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
We need set-rate-parent flags for the display's clock path so that the
DSS driver can change the clock rate of the PLL.
This patchs adds the ti,set-rate-parent flag to disp_clk and
dpll_disp_m2_ck clock nodes.
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
We need "tbclk" clock data for the functioning of ehrpwm
module. Hence, populating the required clock information
in clock dts file.
Signed-off-by: Sourav Poddar <sourav.poddar@ti.com>
Acked-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Use the ti,fixed-factor-clock version so that autoidle for
dpll_per_clkdcoldo is properly controlled after power management code
is introduced. Without this the clock may be held active even when
it is gated.
Signed-off-by: Dave Gerlach <d-gerlach@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Add USB and USB PHY reference clock data
Signed-off-by: George Cherian <george.cherian@ti.com>
Acked-by: Roger Quadros <rogerq@ti.com>
Acked-by: Felipe Balbi <balbi@ti.com>
[tony@atomide.com: tabified]
Signed-off-by: Tony Lindgren <tony@atomide.com>
This patch creates a unique node for each clock in the AM43xx power,
reset and clock manager (PRCM).
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>