The current is given by the formular from page 12 of
https://www.ti.com/lit/ds/symlink/lm36922.pdf. We use this to limit the
led's max_brightness using the led-max-microamp DT property.
The formula for the lm36923 is identical according to the data sheet.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
Overvoltage protection is currently using the default of 29V. Make it
configurable via DT.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB
since the later is a flag for the PWM register. The
actual register value remains unchanged.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
The current setup of LM3692X_BOOST_CTRL uses flags from LM3692X_BRT_CTRL.
Use flags from LM3692X_BOOST_CTRL but leave the resulting register value
unchanged.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
Instead use devm_regulator_get_optional since the regulator
is optional and check for errors.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
The driver currently reports successful initialization on every failure
as long as it's able to power off the regulator. Don't check the return
value of regulator_disable to avoid that.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
This gives a way better idea what is going on.
Signed-off-by: Guido Günther <agx@sigxcpu.org>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
Switch to using generic LED support for composing LED class
device name.
At this occassion remove initialization of struct led_classdev's
dev->of_node property in the driver, since now it will be taken from
fwnode assigned to struct led_init_data and passed to the new
devm_led_classdev_register_ext() API.
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>
Tested-by: Dan Murphy <dmurphy@ti.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
The LM36922 has one output but can sync current to 2 LED
strings. The user may only use one sync so the other
syncs need to be disabled.
The LM36923 has 3 LED syncs.
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>
Update the code to use the fwnode calls as opposed
to ARM DT node api's.
This allows the device to be used with either DT
configurations or ACPI definitions.
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>
Update the license header to the current
SPDX licensing format.
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>
Introducing the LM3692x Dual-String white LED driver.
Data sheet is located
http://www.ti.com/lit/ds/snvsa29/snvsa29.pdf
Signed-off-by: Dan Murphy <dmurphy@ti.com>
Signed-off-by: Jacek Anaszewski <jacek.anaszewski@gmail.com>