Since we put static variable to a header file it's copied to each module
that includes the header. But not all of them are actually used it.
Mark default_press_pdata with __maybe_unused to calm a compiler down:
In file included from drivers/iio/pressure/st_pressure_spi.c:18:
drivers/iio/pressure/st_pressure.h:40:46: warning: ‘default_press_pdata’ defined but not used [-Wunused-const-variable=]
40 | static const struct st_sensors_platform_data default_press_pdata = {
| ^~~~~~~~~~~~~~~~~~~
...
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The function is introduced to retrieve press device settings. It will be
used by probe in order to configure regmap.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Based on 1 normalized pattern(s):
licensed under the gpl 2
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 135 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Allison Randal <allison@lohutok.net>
Reviewed-by: Richard Fontana <rfontana@redhat.com>
Reviewed-by: Alexios Zavras <alexios.zavras@intel.com>
Reviewed-by: Steve Winslow <swinslow@gmail.com>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190528170026.071193225@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Initial support for ST LPS22HH pressure sensor. Datasheet:
http://www2.st.com/resource/en/datasheet/lps22hh.pdf
Features:
* pressure, temperature data and timestamping channels
* sampling frequency selection [1..200] Hz
* interrupt based trigger
* over I2C or SPI interface
Signed-off-by: mario tesi <mario.tesi@st.com>
Acked-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Compatible strings are not available on ACPI based systems. This patch adds
support to use DSDT information read from platform BIOS instead for probing
st pressure sensors.
Signed-off-by: Shrirang Bagul <shrirang.bagul@canonical.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Initial support for ST LPS22HB pressure sensor. Datasheet:
http://www2.st.com/resource/en/datasheet/lps22hb.pdf
Features:
* pressure data and timestamping channels
* sampling frequency selection
* interrupt based trigger
* over I2C or SPI
Signed-off-by: Gregor Boirie <gregor.boirie@parrot.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch adds support for the new barometer sensor: LPS25H.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Here we use existing practices to introduce support for another
pressure/temperature sensor, the LPS001WP.
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch add support to redirect the DRDY interrupt on INT1 or INT2
on accelerometer and pressure sensors.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch adds a generic pressure driver for STMicroelectronics
pressure sensors, currently it supports: LPS331AP.
Signed-off-by: Denis Ciocca <denis.ciocca@st.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>