Adam Wujek d1baf7a3a3 hwmon: (pmbus) Check PEC support before reading other registers
Make sure that the support of PEC is determined before the read of other
registers. Otherwise the validation of PEC can trigger an error on the read
of STATUS_BYTE or STATUS_WORD registers.

The problematic scenario is the following. A device with enabled PEC
support is up and running and a kernel driver is loaded.
Then the driver is unloaded (or device unbound), the HW device
is reconfigured externally (e.g. by i2cset) to advertise itself as not
supporting PEC. Without the move of the code, at the second load of
the driver (or bind) the STATUS_BYTE or STATUS_WORD register is always
read with PEC enabled, which is likely to cause a read error resulting
with fail of a driver load (or bind).

Signed-off-by: Adam Wujek <dev_public@wujek.eu>
Link: https://lore.kernel.org/r/20220519233334.438621-1-dev_public@wujek.eu
Fixes: 75d2b2b06b ("hwmon: (pmbus) disable PEC if not enabled")
Fixes: 4e5418f787 ("hwmon: (pmbus_core) Check adapter PEC support")
[groeck: Added Fixes: tags, dropped continuation line]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-22 11:32:32 -07:00
Mårten Lindahl 28bf22ef93 hwmon: (pmbus) Add get_voltage/set_voltage ops
The pmbus core does not have operations for getting or setting voltage.
Add functions get/set voltage for the dynamic regulator framework.

Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Link: https://lore.kernel.org/r/20220503104631.3515715-5-marten.lindahl@axis.com
[groeck: cosmetic alignment / empty line fixes]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-22 11:32:31 -07:00
Eduardo Valentin 3aa74796cf hwmon: (pmbus) Register with thermal for PSC_TEMPERATURE
Some pmbus device drivers have device tree support and
may want to use of-thermal to register a thermal zone
OF sensor for those device drivers.

This way we allow describing device tree thermal zones
for pmbus device drivers with device tree support.

This patch achieves this by registering pmbus sensors
with thermal subsystem if they are PSC_TEMPERATURE
and are providing _input hwmon interface.

Cc: Guenter Roeck <linux@roeck-us.net> (maintainer:PMBUS HARDWARE MONITORING DRIVERS)
Cc: Jean Delvare <jdelvare@suse.com> (maintainer:HARDWARE MONITORING)
Cc: linux-hwmon@vger.kernel.org (open list:PMBUS HARDWARE MONITORING DRIVERS)
Cc: linux-kernel@vger.kernel.org (open list)
Signed-off-by: Eduardo Valentin <eduval@amazon.com>
Signed-off-by: Eduardo Valentin <evalenti@kernel.org>
Link: https://lore.kernel.org/r/20220428174926.2150-1-eduval@amazon.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-22 11:32:31 -07:00
Greg.Schwendimann@infineon.com 9054416afc hwmon: (pmbus) Add support for Infineon Digital Multi-phase xdp152 family controllers
Add support for devices XDPE152C4, XDPE12584.

Signed-off-by: Greg Schwendimann <Greg.Schwendimann@infineon.com>
Link: https://lore.kernel.org/r/5e6d50e9b28140158f339b0de343eea4@infineon.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-22 11:32:20 -07:00
Mårten Lindahl b90f994a37 hwmon: (pmbus/ltc2978) Add chip specific write_byte_data
Several of the manuals for devices supported by this driver describes
the need for a minimum wait time before the chip is ready to receive
next command.

This wait time is already implemented in the driver as a ltc_wait_ready
function with a driver defined wait time of 100 ms, and is considered
for specific devices before reading/writing data on the pmbus.

Since this driver uses the default pmbus_regulator_ops for the enable/
disable/is_enabled functions we should add a driver specific callback
for write_byte_data to prevent bypassing the wait time recommendations
for the following devices: ltc3880/ltc3882/ltc3883/ltc3884/ltc3886/
ltc3887/ltc3889/ltm4664/ltm4675/ltm4676/ltm4677/ltm4678/ltm4680/ltm4686/
ltm4700/ltc7880.

Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Link: https://lore.kernel.org/r/20220428144039.2464667-4-marten.lindahl@axis.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20 10:57:06 -07:00
Mårten Lindahl f0a5c83976 hwmon: (pmbus) Use _pmbus_read_byte_data with callback
Some of the pmbus core functions uses pmbus_read_byte_data, which does
not support driver callbacks for chip specific write operations. This
could potentially influence some specific regulator chips that for
example need a time delay before each data access.

Lets use _pmbus_read_byte_data with callback check.

Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Link: https://lore.kernel.org/r/20220428144039.2464667-3-marten.lindahl@axis.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20 10:57:06 -07:00
Mårten Lindahl 5de3e13f7f hwmon: (pmbus) Introduce and use write_byte_data callback
Some of the pmbus core functions uses pmbus_write_byte_data, which does
not support driver callbacks for chip specific write operations. This
could potentially influence some specific regulator chips that for
example need a time delay before each data access.

Lets add support for driver callback with _pmbus_write_byte_data.

Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Link: https://lore.kernel.org/r/20220428144039.2464667-2-marten.lindahl@axis.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20 10:57:06 -07:00
Atif Ofluoglu e5c498ccc9 hwmon: (pmbus/max16601) Add MAX16602 support
Adding another MAX16602 chip support to MAX16601 driver
Tested with MAX16602 works as expected.

Signed-off-by: Atif Ofluoglu <atif.ofluoglu@maximintegrated.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20 10:57:05 -07:00
Zev Weiss 08da09f028 hwmon: (pmbus) delta-ahe50dc-fan: work around hardware quirk
CLEAR_FAULTS commands can apparently sometimes trigger catastrophic
power output glitches on the ahe-50dc, so block them from being sent
at all.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Cc: stable@vger.kernel.org
Link: https://lore.kernel.org/r/20220427035109.3819-1-zev@bewilderbeest.net
Fixes: d387d88ed0 ("hwmon: (pmbus) Add Delta AHE-50DC fan control module driver")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-04-27 04:52:18 -07:00
Adam Wujek 75d2b2b06b hwmon: (pmbus) disable PEC if not enabled
Explicitly disable PEC when the client does not support it.
The problematic scenario is the following. A device with enabled PEC
support is up and running and a kernel driver is loaded.
Then the driver is unloaded (or device unbound), the HW device
is reconfigured externally (e.g. by i2cset) to advertise itself as not
supporting PEC. Without a new code, at the second load of the driver
(or bind) the "flags" variable is not updated to avoid PEC usage. As a
consequence the further communication with the device is done with
the PEC enabled, which is wrong and may fail.

The implementation first disable the I2C_CLIENT_PEC flag, then the old
code enable it if needed.

Fixes: 4e5418f787 ("hwmon: (pmbus_core) Check adapter PEC support")
Signed-off-by: Adam Wujek <dev_public@wujek.eu>
Link: https://lore.kernel.org/r/20220420145059.431061-1-dev_public@wujek.eu
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-04-25 09:15:20 -07:00
Guenter Roeck d6732317a5 hwmon: (xdpe12284) Fix build warning seen if CONFIG_SENSORS_XDPE122_REGULATOR is disabled
0-day reports:

drivers/hwmon/pmbus/xdpe12284.c:127:36: warning:
	unused variable 'xdpe122_reg_desc'

This is seen if CONFIG_SENSORS_XDPE122_REGULATOR is not enabled.
Mark xdpe122_reg_desc as __maybe_unused to fix the problem.

Fixes: f53bfe4d69 ("hwmon: (xdpe12284) Add regulator support")
Reported-by: kernel test robot <lkp@intel.com>
Cc: Marcello Sylvester Bauer <sylv@sylv.io>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-04-04 06:54:30 -07:00
Brandon Wyman a5436af598 hwmon: (pmbus) Add Vin unit off handling
If there is an input undervoltage fault, reported in STATUS_INPUT
command response, there is quite likely a "Unit Off For Insufficient
Input Voltage" condition as well.

Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit
attributes to include both bits in the mask for clearing faults.

If an input undervoltage fault occurs, causing a unit off for
insufficient input voltage, but the unit is off bit is not cleared, the
STATUS_WORD will not be updated to clear the input fault condition.
Including the unit is off bit (bit 3) allows for the input fault
condition to completely clear.

Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com
Fixes: b4ce237b7f ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers")
[groeck: Dropped unnecessary ()]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-03-17 22:30:28 -07:00
Potin Lai a3cd66d7cb hwmon: (adm1275) Allow setting sample averaging
Current driver assume PWR_AVG and VI_AVG as 1 by default, and user needs
to set sample averaging via sysfs manually.

This patch parses the properties "adi,power-sample-average" and
"adi,volt-curr-sample-average" from device tree, and setting sample
averaging during probe. Input value must be one of value in the
list [1, 2, 4, 8, 16, 32, 64, 128].

Signed-off-by: Potin Lai <potin.lai@quantatw.com>
Link: https://lore.kernel.org/r/20220302123817.27025-2-potin.lai@quantatw.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-03-02 09:57:18 -08:00
Marcello Sylvester Bauer f53bfe4d69 hwmon: (xdpe12284) Add regulator support
Add simple on/off regulator support for xdpe12284 and
other pmbus parts supported by the xdpe12284 driver.

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/f69b8e7fa32cd2bad9516d8fa590abb87c7e4869.1646214248.git.sylv@sylv.io
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-03-02 09:51:15 -08:00
Marcello Sylvester Bauer efdab64d88 hwmon: (xdpe12284) Add support for xdpe11280
Add support for another Infineon Multi-phase controller chip. The
xdpe11280 uses linear instead of vid data format for VOUT. Detect
VOUT_MODE format during identification and skip the xdpe122 related
adaptions in case it is linear.

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/fa6a4b636a05ecb337d132824efca2545188a2a2.1646214248.git.sylv@sylv.io
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-03-02 09:51:11 -08:00
Marcello Sylvester Bauer ba1d263af1 hwmon: (pmbus/pli1209bc) Add regulator support
Add regulator support for PLI1209BC Digital Supervisor.

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/21b0cdb6dd72654effa451d3b1636ecd07b160e9.1645435888.git.sylv@sylv.io
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:19 -08:00
Marcello Sylvester Bauer d0cd978513 hwmon: (pmbus) Add support for pli1209bc
PLI1209BC is a Digital Supervisor from Vicor Corporation.

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/4e016e66275bc46c90974aec18b150c874e64787.1645435888.git.sylv@sylv.io
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:19 -08:00
Marcello Sylvester Bauer 54cc3dbfc1 hwmon: (pmbus) Add regulator supply into macro
Add regulator supply into PWBUS_REGULATOR macro. This makes it optional
to define a vin-supply in DT. Not defining a supply will add a dummy
regulator supply instead and only cause the following debug output:

```
Looking up vin-supply property in node [...] failed
```

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/58f2ff7b90233fad3d7ae2e9d66d5192e2c1ac01.1645437439.git.sylv@sylv.io
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:19 -08:00
Zev Weiss da78ad2b6b hwmon: (pmbus/lm25066) Add regulator support
While these chips aren't strictly advertised as voltage regulators per
se, they (aside from the lm25056) support the PMBus OPERATION command
to enable and disable their outputs and have status bits for reporting
various warnings and faults, and can hence usefully support all the
pmbus_regulator_ops operations.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20220219000742.20126-1-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:18 -08:00
Zev Weiss e0f0307ac1 hwmon: (pmbus) Add get_error_flags support to regulator ops
The various PMBus status bits don't all map perfectly to the more
limited set of REGULATOR_ERROR_* flags, but there's a reasonable
number where they correspond well enough.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20220219000359.19985-1-zev@bewilderbeest.net
[groeck: Added missing locking]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:18 -08:00
Marcello Sylvester Bauer e505e44fb0 hwmon: (pmbus) Remove trailing whitespaces from Kconfig file
Fix checkpatch issues by removing trailing whitespaces in Kconfig.

Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/c984b88b136a1cde16ce52c5f818886653b0f84a.1642434222.git.sylv@sylv.io
[groeck: Updated subject]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:17 -08:00
Patrick Rudolph 686d303ee6 hwmon: (pmbus) Add mutex to regulator ops
On PMBUS devices with multiple pages, the regulator ops need to be
protected with the update mutex. This prevents accidentally changing
the page in a separate thread while operating on the PMBUS_OPERATION
register.

Tested on Infineon xdpe11280 while a separate thread polls for sensor
data.

Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io>
Link: https://lore.kernel.org/r/b991506bcbf665f7af185945f70bf9d5cf04637c.1645804976.git.sylv@sylv.io
Fixes: ddbb4db4ce ("hwmon: (pmbus) Add regulator support")
Cc: Alan Tull <atull@opensource.altera.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:02:36 -08:00
Vikash Chandola 35f165f089 hwmon: (pmbus) Clear pmbus fault/warning bits after read
Almost all fault/warning bits in pmbus status registers remain set even
after fault/warning condition are removed. As per pmbus specification
these faults must be cleared by user.
Modify hwmon behavior to clear fault/warning bit after fetching data if
fault/warning bit was set. This allows to get fresh data in next read.

Signed-off-by: Vikash Chandola <vikash.chandola@linux.intel.com>
Link: https://lore.kernel.org/r/20220222131253.2426834-1-vikash.chandola@linux.intel.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-22 08:15:39 -08:00
Guenter Roeck f1e75e0d6a hwmon: (pmbus/ir38064) Mark ir38064_of_match as __maybe_unused
If CONFIG_PM is not enabled, the following warning is reported.

drivers/hwmon/pmbus/ir38064.c:54:34: warning:
	unused variable 'ir38064_of_match'

Mark it as __maybe_unused.

Reported-by: kernel test robot <lkp@intel.com>
Cc: Arthur Heymans <arthur.heymans@9elements.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-01-23 18:21:27 -08:00
Colin Ian King 23c7df14f6 hwmon/pmbus: (ir38064) Fix spelling mistake "comaptible" -> "compatible"
There is a spelling mistake in the module description, fix it.

Signed-off-by: Colin Ian King <colin.i.king@gmail.com>
Link: https://lore.kernel.org/r/20211220155527.179125-1-colin.i.king@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:07 -08:00
Patrick Rudolph 0ee7f62426 hwmon/pmbus: (ir38064) Expose a regulator
The chip series supported by this driver are voltage regulators, so expose
them to the regulator subsystem.

Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
Link: https://lore.kernel.org/r/20211213142814.264802-4-arthur.heymans@9elements.com
[groeck: Added brief patch description]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:07 -08:00
Arthur Heymans e65de225ef hwmon/pmbus: (ir38064) Add of_match_table
Add the missing of_match_table to allow device tree probing.

Signed-off-by: Arthur Heymans <arthur.heymans@9elements.com>
Link: https://lore.kernel.org/r/20211213142814.264802-3-arthur.heymans@9elements.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:07 -08:00
Patrick Rudolph ca003af3aa hwmon/pmbus: (ir38064) Add support for IR38060, IR38164 IR38263
The IR38060, IR38164 and IR38263 can be supported using this driver.

Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com>
Signed-off-by: Arthur Heymans <arthur.heymans@9elements.com>
Link: https://lore.kernel.org/r/20211213142814.264802-2-arthur.heymans@9elements.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:07 -08:00
Howard.Chiu@quantatw.com e1c5cd7e8a hwmon: (pmbus) Add support for MPS Multi-phase mp5023
Add support for mp5023 device from Monolithic Power Systems, Inc. (MPS)
vendor. This is a Hot-Swap Controller.

Signed-off-by: Howard Chiu <howard.chiu@quantatw.com>
Link: https://lore.kernel.org/r/HKAPR04MB400349AA406694FB976D78D096709@HKAPR04MB4003.apcprd04.prod.outlook.com
[groeck: Added MODULE_IMPORT_NS, entry in index.rst]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:06 -08:00
Zev Weiss d387d88ed0 hwmon: (pmbus) Add Delta AHE-50DC fan control module driver
This device is an integrated module of the Delta AHE-50DC Open19 power
shelf.  I haven't been able to procure any proper documentation for
it, but it seems to be a (somewhat minimally) PMBus-compliant device.
It provides four fan speeds, four temperatures (three standard and one
manufacturer-specific via a virtual second page), and a vin reading.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20211208213703.2577-2-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:06 -08:00
Brandon Wyman 8a5cfcfa94 hwmon: (pmbus/ibm-cffps) Use MFR_ID to choose version
There are multiple power supplies that will indicate
CFFPS_CCIN_VERSION_1, use the manufacturer ID to determine if it should
be treated as version cffps1 or version cffps2.

Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20211004144339.2634330-2-bjwyman@gmail.com
[groeck: Fixed continuation line alignment]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:41 -07:00
Brandon Wyman a111ec399c hwmon: (pmbus/ibm-cffps) Add mfg_id debugfs entry
Add support for the manufacturer ID to the debugfs entries.

Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20211004144339.2634330-1-bjwyman@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:41 -07:00
Zev Weiss 94ee5fcc24 hwmon: (pmbus/lm25066) Support configurable sense resistor values
The appropriate mantissa values for the lm25066 family's direct-format
current and power readings are a function of the sense resistor
employed between the SENSE and VIN pins of the chip.  Instead of
assuming that resistance is always the same 1mOhm as used in the
datasheet, allow it to be configured via a device-tree property
("shunt-resistor-micro-ohms").

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-8-zev@bewilderbeest.net
[groeck: Fixed checkpatch warnings]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:41 -07:00
Zev Weiss b7792f3ea3 hwmon: (pmbus/lm25066) Add OF device ID table
The driver doesn't have a struct of_device_id table but supported devices
are registered via Device Trees. This is working on the assumption that a
I2C device registered via OF will always match a legacy I2C device ID and
that the MODALIAS reported will always be of the form i2c:<device>.

But this could change in the future so the correct approach is to have an
OF device ID table if the devices are registered via OF.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-7-zev@bewilderbeest.net
[groeck: Replaced reference to reasoning with reasoning, fixed checkpatch
 warnings, fixed compile warning comparing of_id->data w/ i2c_id->driver_data]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Zev Weiss df60a5daa7 hwmon: (pmbus/lm25066) Mark lm25066_coeff array const
lm25066_coeff is read-only. Mark it as such.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-6-zev@bewilderbeest.net
[groeck: Added description]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Zev Weiss b7931a7b0e hwmon: (pmbus/lm25066) Let compiler determine outer dimension of lm25066_coeff
Maintaining this manually is error prone (there are currently only
five chips supported, not six); gcc can do it for us automatically.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Fixes: 666c14906b ("hwmon: (pmbus/lm25066) Drop support for LM25063")
Link: https://lore.kernel.org/r/20210928092242.30036-5-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Zev Weiss 6d2ff184cb hwmon: (pmbus/lm25066) Avoid forward declaration of lm25066_id
Reordering things to put the table before the probe function
eliminates the need for it.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-4-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Zev Weiss fa16188fa2 hwmon: (pmbus/lm25066) Adjust lm25066 PSC_CURRENT_IN_L mantissa
At least as of Revision J, the datasheet has a slightly different
value than what we'd had in the driver.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-3-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Zev Weiss ae59dc455a hwmon: (pmbus/lm25066) Add offset coefficients
With the exception of the lm5066i, all the devices handled by this
driver had been missing their offset ('b') coefficients for direct
format readings.

Cc: stable@vger.kernel.org
Fixes: 58615a94f6 ("hwmon: (pmbus/lm25066) Add support for LM25056")
Fixes: e53e6497fc ("hwmon: (pmbus/lm25066) Refactor device specific coefficients")
Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20210928092242.30036-2-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-12 07:22:40 -07:00
Vadim Pasternak 2292e2f685 hwmon: (pmbus/mp2975) Add missed POUT attribute for page 1 mp2975 controller
Add missed attribute for reading POUT from page 1.
It is supported by device, but has been missed in initial commit.

Fixes: 2c6fcbb211 ("hwmon: (pmbus) Add support for MPS Multi-phase mp2975 controller")
Signed-off-by: Vadim Pasternak <vadimp@nvidia.com>
Link: https://lore.kernel.org/r/20210927070740.2149290-1-vadimp@nvidia.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-02 04:45:49 -07:00
Brandon Wyman f067d5585c hwmon: (pmbus/ibm-cffps) max_power_out swap changes
The bytes for max_power_out from the ibm-cffps devices differ in byte
order for some power supplies.

The Witherspoon power supply returns the bytes in MSB/LSB order.

The Rainier power supply returns the bytes in LSB/MSB order.

The Witherspoon power supply uses version cffps1. The Rainier power
supply should use version cffps2. If version is cffps1, swap the bytes
before output to max_power_out.

Tested:
    Witherspoon before: 3148. Witherspoon after: 3148.
    Rainier before: 53255. Rainier after: 2000.

Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Reviewed-by: Eddie James <eajames@linux.ibm.com>
Link: https://lore.kernel.org/r/20210928205051.1222815-1-bjwyman@gmail.com
[groeck: Replaced yoda programming]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-10-02 04:38:53 -07:00
Chris Packham 1125bacbf3 hwmon: (pmbus/bpa-rs600) Add workaround for incorrect Pin max
BPD-RS600 modules running firmware v5.70 misreport the MFR_PIN_MAX.
The indicate a maximum of 1640W instead of 700W. Detect the invalid
reading and return a sensible value instead.

Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Link: https://lore.kernel.org/r/20210812014000.26293-3-chris.packham@alliedtelesis.co.nz
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-17 14:54:27 -07:00
Chris Packham 7a8c68c57f hwmon: (pmbus/bpa-rs600) Don't use rated limits as warn limits
In the initial implementation a number of PMBUS_x_WARN_LIMITs were
mapped to MFR fields. This was incorrect as these MFR limits reflect the
rated limit as opposed to a limit which will generate warning. Instead
return -ENXIO like we were already doing for other WARN_LIMITs.

Subsequently these rated limits have been exposed generically as new
fields in the sysfs ABI so the values are still available.

Fixes: 15b2703e5e ("hwmon: (pmbus) Add driver for BluTek BPA-RS600")
Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Link: https://lore.kernel.org/r/20210812014000.26293-2-chris.packham@alliedtelesis.co.nz
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-17 14:54:26 -07:00
Brandon Wyman 76b72736f5 hwmon: (pmbus/ibm-cffps) Fix write bits for LED control
When doing a PMBus write for the LED control on the IBM Common Form
Factor Power Supplies (ibm-cffps), the DAh command requires that bit 7
be low and bit 6 be high in order to indicate that you are truly
attempting to do a write.

Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20210806225131.1808759-1-bjwyman@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-17 14:54:26 -07:00
Chris Packham 129cdce375 hwmon: (pmbus/bpa-rs600) Support BPD-RS600
The BPD-RS600 is the DC version of the BPA-RS600. The PMBUS interface is
the same between the two models. Keep the same compatible string but
accept either BPA-RS600 or BPD-RS600 in the PMBUS_MFR_MODEL.

Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Link: https://lore.kernel.org/r/20210708220618.23576-1-chris.packham@alliedtelesis.co.nz
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-17 14:54:25 -07:00
Dan Carpenter 9e25f01b5f hwmon: (pmbus/dps920ab) Delete some dead code
The debugfs_create_dir() function returns error pointers, it doesn't
return NULL.  But debugfs functions don't need to be checked in normal
situations and we can just delete this code.

Fixes: 1f442e213ce5 ("hwmon: (pmbus) Add driver for Delta DPS-920AB PSU")
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Link: https://lore.kernel.org/r/YMyjmR54ErLtc1sH@mwanda
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-06-18 12:45:58 -07:00
Robert Marko 3efbcee8d4 hwmon: (pmbus) Add driver for Delta DPS-920AB PSU
This adds support for the Delta DPS-920AB PSU.

Only missing feature is fan control which the PSU supports.

Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Link: https://lore.kernel.org/r/20210607103431.2039073-1-robert.marko@sartura.hr
[groeck: Add MODULE_IMPORT_NS(PMBUS);]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-06-17 04:21:46 -07:00
Erik Rosen 317f9d808a hwmon: (pmbus/pim4328) Add PMBus driver for PIM4006, PIM4328 and PIM4820
Add hardware monitoring support for Flex power interface modules PIM4006,
PIM4328 and PIM4820.

Signed-off-by: Erik Rosen <erik.rosen@metormote.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-06-17 04:21:46 -07:00
Erik Rosen 5e86f128d9 hwmon: (pmbus) Allow phase function even if it's not on page
Allow the use of a phase function even if it does not exist on
the associated page.

Signed-off-by: Erik Rosen <erik.rosen@metormote.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-06-17 04:21:46 -07:00
Erik Rosen e8e00c83a2 hwmon: (pmbus) Add support for reading direct mode coefficients
Add support for reading and decoding direct format coefficients to
the PMBus core driver. If the new flag PMBUS_USE_COEFFICIENTS_CMD
is set, the driver will use the COEFFICIENTS register together with
the information in the pmbus_sensor_attr structs to initialize
relevant coefficients for the direct mode format.

Signed-off-by: Erik Rosen <erik.rosen@metormote.com>
[groeck: Initialize ret with -EINVAL in pmbus_init_coefficients()]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>