The equivalent of this is now done via macro magic when
the relevant register call is made. The actual structure
elements will shortly go away.
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Reviewed-by: Lars-Peter Clausen <lars@metafoo.de>
Environmental temperature sensor is a hid defined sensor,
it measures temperature.
More information can be found in:
http://www.usb.org/developers/hidpage/HUTRR39b.pdf
According to IIO ABI definition, IIO_TEMP data output unit is
milli degrees Celsius. Add the unit convert from degree to milli degree.
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>