This commit adds support for the GENETv5 implementation.
The GENETv5 reports a major version of 6 instead of 5 so compensate
for this when verifying the configuration of the driver. Also the
EPHY revision is now contained in the MDIO registers of the PHY so
the EPHY revision of 0 in GENET_VER_FMT is expected for GENETv5.
Signed-off-by: Doug Berger <opendmb@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Have mdio_alloc() create the array of interrupt numbers, and
initialize it to POLLING. This is what most MDIO drivers want, so
allowing code to be removed from the drivers.
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This platform driver has a OF device ID table but the OF module
alias information is not created so module autoloading won't work.
Signed-off-by: Luis de Bethencourt <luisbg@osg.samsung.com>
Acked-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
All BCM7xxx integrated Gigabit PHYs have an issue in their MDIO
management controller which will make the initial read or write to them
to fail and return 0xffff. This is a real issue as the typical first
thing we do is read from MII_PHYSID1 and MII_PHYSID2 from get_phy_id()
to register a driver for these PHYs.
Coupled with the workaround in drivers/net/phy/bcm7xxx.c, this
workaround for the MDIO bus controller consists in scanning the list of
PHYs to do this initial read workaround for as part of the MDIO bus
reset routine which is invoked prior to mdiobus_scan().
Once we have a proper PHY driver/device registered, all workarounds are
located there (e.g: power management suspend/resume calls).
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Some Ethernet PHYs/switches such as Broadcom's BCM53125 have a hardware bug
which makes them not release the MDIO line during turn-around time. This gets
flagged by the UniMAC MDIO controller as a read failure, and we fail the read
transaction.
Check the MDIO bus phy_ignore_ta_mask bitmask for the PHY we are reading
from and if it is listed in this bitmask, ignore the read failure and
proceed with returning the data we read out of the controller.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
of_device_id is always used as const.
(See driver.of_match_table and open firmware functions)
Signed-off-by: Fabian Frederick <fabf@skynet.be>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/phy/mdio-bcm-unimac.c:195:37-38: unimac_mdio_ids is not NULL
terminated at line 195
Make sure of_device_id tables are NULL terminated
Generated by: scripts/coccinelle/misc/of_table.cocci
Signed-off-by: Fengguang Wu <fengguang.wu@intel.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add a generic UniMAC MDIO bus driver and its Device Tree binding, which
can be used by the BCMGENET driver as-is, and the upcoming Starfighter 2
Ethernet switch MDIO bus controller.
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>