Revert 'I2S Reference' to SOC_ENUM_EXT because the settings are specific
for some platforms, the default setting for 'I2S Reference' does nothing,
only some SoC platform need to configure it.
Previous 'I2S Reference' in SOC_ENUM format only toggles one bit of
RT1011_TDM1_SET_1 register, which isn't enough for specific platform.
Signed-off-by: Jack Yu <jack.yu@realtek.com>
Link: https://lore.kernel.org/r/20211111091705.20879-1-jack.yu@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
There are several things the patch adding the support for 'I2S Reference'
got wrong:
- "None" selection is in fact equals to last selected reference
- The custom put overrides RX/TX len, TDM slot sizes, etc
- the enum is useless in most part for the reference tracking
- there is no need for EXT control as there is a single bit in
RT1011_TDM1_SET_1 register (bit 7) which selects the reference
- it was using ucontrol->value.integer.value[0] in the put/get callbacks
which causesed access to 'I2S Reference' enum with alsamixer to fail
Complements: c3de683c4d ("ASoC: rt1011: Fix 'I2S Reference' enum control caused error")
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@linux.intel.com>
Link: https://lore.kernel.org/r/20211013123300.11095-1-peter.ujfalusi@linux.intel.com
Signed-off-by: Mark Brown <broonie@kernel.org>
For latest design, different package could use the same setting,
therefore the check of pack_id will no longer be used.
Signed-off-by: Jack Yu <jack.yu@realtek.com>
Link: https://lore.kernel.org/r/4cbe1cd3b8664140889132464c7dee7b@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
The QFN package is a new one.
There is a different initial setting to the chip of QFN and WLCSP package.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20200116091854.18095-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
Typically, the r0 (calibration data) and temperature were measured in the factory.
This information is written into the non-volatile area
where keeps data whether factory reset or OS update.
In Chromium OS case, the coreboot will read the info from VPD and create
the device property for each rt1011.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Tested-By: Cheng-Yi Chiang <cychiang@chromium.org>
Link: https://lore.kernel.org/r/20191016085845.11672-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
The factory test needs to know whether the calibration completed.
This flag helps to confirm the calibration completed or not.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20190806091459.14382-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
- The user level application could set the R0 temperature after booting system.
The degree Celsius of R0 temperature store in the non-volatile space
when doing R0 calibration.
- TDM1 ADC2DAT Swap controls use to control TDM slot2/3 data
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20190806091435.14329-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>