Remove the 31 bit syscalls from the syscall table. This is a separate patch
just in case I screwed something up so it can be easily reverted.
However the conversion was done with a script, so everything should be ok.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Add the new __NR_s390_pci_mmio_write and __NR_s390_pci_mmio_read
system calls to allow user space applications to access device PCI I/O
memory pages on s390x platform.
[ Martin Schwidefsky: some code beautification ]
Signed-off-by: Alexey Ishchuk <aishchuk@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Actually this also enable sys_setattr and sys_getattr, since I forgot to
increase NR_syscalls when adding those syscalls.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Now that all compat syscalls have been converted to use the
COMPAT_SYSCALL_DEFINE macros, we don't need to compat syscall
wrapper assembly code anymore.
So remove it and fix up the system call table accordingly.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
The compat syscall wrappers for sync_file_range and fallocate merged 32 bit
parameters into 64 bit parameters. Therefore they did more than just the
usual zero and/or sign extension of system call parameters.
So convert these two wrappers to full s390 specific compat sytem calls.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Introduce a new compat_wrap.c file which contains the s390 specific compat
system call wrappers.
The s390 specific system call wrappers only perform sign, zero and pointer
conversion of system call arguments before actually calling the non-compat
system call.
Therefore introduce COMPAT_SYSCALL_WRAPx macros which generate C code that
is nearly identical to the assembly code. This has the advantage that the
compile will generate correct code, and we avoid the frequent copy-paste
errors seen in the compat_wrapper.S file.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Convert s390 specific system calls to to the new COMPAT_SYSCALL_DEFINE macro.
This allows us to get rid of the assembly compat wrappers.
Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Pull VFS updates from Al Viro,
Misc cleanups all over the place, mainly wrt /proc interfaces (switch
create_proc_entry to proc_create(), get rid of the deprecated
create_proc_read_entry() in favor of using proc_create_data() and
seq_file etc).
7kloc removed.
* 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/viro/vfs: (204 commits)
don't bother with deferred freeing of fdtables
proc: Move non-public stuff from linux/proc_fs.h to fs/proc/internal.h
proc: Make the PROC_I() and PDE() macros internal to procfs
proc: Supply a function to remove a proc entry by PDE
take cgroup_open() and cpuset_open() to fs/proc/base.c
ppc: Clean up scanlog
ppc: Clean up rtas_flash driver somewhat
hostap: proc: Use remove_proc_subtree()
drm: proc: Use remove_proc_subtree()
drm: proc: Use minor->index to label things, not PDE->name
drm: Constify drm_proc_list[]
zoran: Don't print proc_dir_entry data in debug
reiserfs: Don't access the proc_dir_entry in r_open(), r_start() r_show()
proc: Supply an accessor for getting the data from a PDE's parent
airo: Use remove_proc_subtree()
rtl8192u: Don't need to save device proc dir PDE
rtl8187se: Use a dir under /proc/net/r8180/
proc: Add proc_mkdir_data()
proc: Move some bits from linux/proc_fs.h to linux/{of.h,signal.h,tty.h}
proc: Move PDE_NET() to fs/proc/proc_net.c
...
Allow user-space threads to use runtime instrumentation (RI). To enable RI
for a thread there is a new s390 specific system call, sys_s390_runtime_instr,
that takes as parameter a realtime signal number. If the RI facility is
available the system call sets up a control block for the calling thread with
the appropriate permissions for the thread to modify the control block.
The user-space thread can then use the store and modify RI instructions to
alter the control block and start/stop the instrumentation via RION/RIOFF.
If the user specified program buffer runs full RI triggers an external
interrupt. The external interrupt is translated to a real-time signal that
is delivered to the thread that enabled RI on that CPU. The number of
the real-time signal is the number specified in the RI system call. So,
user-space can select any available real-time signal number in case the
application itself uses real-time signals for other purposes.
The kernel saves the RI control blocks on task switch only if the running
thread was enabled for RI. Therefore, the performance impact on task switch
should be negligible if RI is not used.
RI is only enabled for user-space mode and is disabled for the supervisor
state.
Reviewed-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Jan Glauber <jang@linux.vnet.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>