Based on 1 normalized pattern(s):
this program is free software you can redistribute it and or modify
it under the terms and conditions of the gnu general public license
version 2 as published by the free software foundation this program
is distributed in the hope it will be useful but without any
warranty without even the implied warranty of merchantability or
fitness for a particular purpose see the gnu general public license
for more details you should have received a copy of the gnu general
public license along with this program if not write to the free
software foundation inc 51 franklin st fifth floor boston ma 02110
1301 usa
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 111 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Alexios Zavras <alexios.zavras@intel.com>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190530000436.567572064@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This patch adds support for Fabric Device Management
Interface as per FC-GS-4 spec. in libfc. Any driver
making use of libfc can enable fdmi state machine
for a given lport.
If lport has enabled FDMI support the lport state
machine will transition into FDMI after completing
the DNS states and before entering the SCR state.
The FDMI state transition is such that if there is an
error, it won't stop the lport state machine from
transitioning and the it will behave as if there was
no FDMI support.
The FDMI HBA attributes are registed with the Management
server via Register HBA (RHBA) command and the port
attributes are reigstered using the Register Port(RPA)
command.
Signed-off-by: Neerav Parikh <neerav.parikh@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Acked-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Currently the libfc Common Transport(CT) calls assume that
the CT requests are Name Server specific only. This patch
makes it more flexible to allow more FC-GS services to make
use of these routines.
Signed-off-by: Neerav Parikh <neerav.parikh@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Acked-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
fc_fill_fc_hdr() expects fc_frame as an argument. Introduce __fc_fill_fc_hdr to
accept fc_frame_header as an argument.
Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add functions to fill in an FC header given a request header.
These reduces code lines in fc_lport and fc_rport and works
without an exchange/sequence assigned.
fc_fill_reply_hdr() fills a header for a final reply frame.
fc_fill_hdr() which is similar but allows specifying the
f_ctl parameter.
Add defines for F_CTL values FC_FCTL_REQ and FC_FCTL_RESP.
These can be used for most request and response sequences.
v2 of patch adds a line to copy the frame encapsulation
info from the received frame.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch creates a port_id member in struct fc_lport.
This allows libfc to just deal with fc_lport instances
instead of calling into the fc_host to get the port_id.
This change helps in only using symbols necessary for
operation from the libfc structures. libfc still needs
to change the fc_host_port_id() if the port_id changes
so the presentation layer (scsi_transport_fc) can provide
the user with the correct value, but libfc shouldn't
rely on the presentation layer for operational values.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Customers and certification tests have pointed out that we don't
show up on the switch management software as an initiator.
On some MDS switches 'show fcns database' command shows libfc
initiators as 'fcp' not 'fcp:init' like other initiators.
On others switches, I think the switch gets the features by doing a PRLI,
but it may be only certain models or under certain configurations.
Fix this by registering our FC4 features with the RFF_ID CT request
after local port login and after the RFT_ID.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The strncpy for RSPN_ID and RSNN_NN requests was padding
past the allocated frame size.
Get the string length before filling in the ct header.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The code that filled in the name server RNN_ID (register node name)
request had somehow gotten a line in it from the RFT_ID code
which copies 32 bytes of data over the relatively short payload.
This caused some corruption and hangs.
Simply deleted the extraneous line.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic port name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Register the fc_host symbolic name as the symbolic node name
with the fabric name server.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
One could interpret FC-GS-5 to say that an explicit RNN_ID is required
before RSNN_NN is allowed to succeed, which is why RNN_ID was not obsoleted
along with RPN_ID acording to this document:
ftp://ftp.t11.org/t11/member/fc/gs-5/05-546v2.pdf
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add FDISC ELS handling to libfc and libfcoe, treat it the same as FLOGI where
appropriate.
Add checking for NPIV support in the FLOGI LS_ACC service parameters.
Signed-off-by: Chris Leech <christopher.leech@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When an RSCN indicates changes to individual remote ports,
don't blindly log them out and then back in. Instead, determine
whether they're still in the directory, by doing GPN_ID.
If that is successful, call login, which will send ADISC and reverify,
otherwise, call logoff. Perhaps we should just delete the rport,
not send LOGO, but it seems safer.
Also, fix a possible issue where if a mix of records in the RSCN
cause us to queue disc_ports for disc_single and then we decide
to do full rediscovery, we leak memory for those disc_ports queued.
So, go through the list of disc_ports even if doing full discovery.
Free the disc_ports in any case. If any of the disc_single() calls
return error, do a full discovery.
The ability to fill in GPN_ID requests was added to fc_ct_fill().
For this, it needs the FC_ID to be passed in as an arg.
The did parameter for fc_elsct_send() is used for that, since the
actual D_DID will always be 0xfffffc for all CT requests so far.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When rport_login is called on an rport that is already thought
to be logged in, use ADISC. If that fails, redo PLOGI.
This is less disruptive after fabric changes that don't affect
the state of the target.
Implement the sending of ADISC via fc_els_fill.
Add ADISC state to the rport state machine. This is entered from READY
and returns to READY after successful completion. If it fails, the rport
is either logged off and deleted or re-does PLOGI.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
tt.elsct_send is used by both FCP and by the rport state machine.
After further patches, these two modules will use different
structures for the remote port.
So, change elsct_send to use the FC_ID instead of the fc_rport_priv
as its argument. It currently only uses the FC_ID anyway.
For CT requests the destination FC_ID is still implicitly 0xfffffc.
After further patches the did arg on CT requests will be used to
specify the FC_ID being inquired about for GPN_ID or other queries.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The rport and discovery modules deal with remote ports
before fc_remote_port_add() can be done, because the
full set of rport identifiers is not known at early stages.
In preparation for splitting the fc_rport/fc_rport_priv allocation,
make fc_rport_priv the primary interface for the remote port and
discovery engines.
The FCP / SCSI layers still deal with fc_rport and
fc_rport_libfc_priv, however.
Signed-off-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch adds the /sys/module/libfc/parameters/debug_logging
file to sysfs as a module parameter. It accepts an integer
bitmask for logging. Currently it supports:
bit
LSB 0 = general libfc debugging
1 = lport debugging
2 = disc debugging
3 = rport debugging
4 = fcp debugging
5 = EM debugging
6 = exch/seq debugging
7 = scsi logging (mostly error handling)
the other bits are not used at this time.
The patch converts all of the libfc source files to use
these new macros and removes the old FC_DBG macro.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
libFC is composed of 4 blocks supported by an exchange manager
and a framing library. The upper 4 layers are fc_lport, fc_disc,
fc_rport and fc_fcp. A LLD that uses libfc could choose to
either use libfc's block, or using the transport template
defined in libfc.h, override one or more blocks with its own
implementation.
The EM (Exchange Manager) manages exhcanges/sequences for all
commands- ELS, CT and FCP.
The framing library frames ELS and CT commands.
The fc_lport block manages the library's representation of the
host's FC enabled ports.
The fc_disc block manages discovery of targets as well as
handling changes that occur in the FC fabric (via. RSCN events).
The fc_rport block manages the library's representation of other
entities in the FC fabric. Currently the library uses this block
for targets, its peer when in point-to-point mode and the
directory server, but can be extended for other entities if
needed.
The fc_fcp block interacts with the scsi-ml and handles all
I/O.
Signed-off-by: Robert Love <robert.w.love@intel.com>
[jejb: added include of delay.h to fix ppc64 compile prob spotted by sfr]
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>