As synchronous exceptions really only make sense against the current
task (otherwise how are you synchronous) remove the task parameter
from from force_sig_fault to make it explicit that is what is going
on.
The two known exceptions that deliver a synchronous exception to a
stopped ptraced task have already been changed to
force_sig_fault_to_task.
The callers have been changed with the following emacs regular expression
(with obvious variations on the architectures that take more arguments)
to avoid typos:
force_sig_fault[(]\([^,]+\)[,]\([^,]+\)[,]\([^,]+\)[,]\W+current[)]
->
force_sig_fault(\1,\2,\3)
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
Update the calls of force_sig_fault that pass in a variable that is
set to current earlier to explicitly use current.
This is to make the next change that removes the task parameter
from force_sig_fault easier to verify.
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
The send_sigtrap function is always called with tsk == current.
Make that obvious by removing the tsk parameter.
This also makes it clear that send_sigtrap always calls
force_sig_fault on the current task.
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
All of the remaining callers pass current into force_sig so
remove the task parameter to make this obvious and to make
misuse more difficult in the future.
This also makes it clear force_sig passes current into force_sig_info.
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
This patch set contains basic components for supporting the nds32 FPU,
such as exception handlers and context switch for FPU registers. By
default, the lazy FPU scheme is supported and the user can configure it via
CONFIG_LZAY_FPU.
Signed-off-by: Vincent Chen <vincentc@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
It may print too much information sometimes if the stack is wrong or
too big. This patch can limit the debug information in a page of stack.
Signed-off-by: Greentime Hu <greentime@andestech.com>
Use macro to replace the magic number.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
We are not using NDS32 ABI 2 for now, just remove the preprocessor
directives __NDS32_ABI_2.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
Function graph tracer has modified the return address to
'return_to_handler' on stack, and provide the 'ftrace_graph_ret_addr' to
get the real return address.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
The compiler predefined macro 'NDS32_ABI_2' had been removed, it should
use the '__NDS32_ABI_2' here.
Signed-off-by: Zong Li <zong@andestech.com>
Acked-by: Greentime Hu <greentime@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
Filling in struct siginfo before calling force_sig_info a tedious and
error prone process, where once in a great while the wrong fields
are filled out, and siginfo has been inconsistently cleared.
Simplify this process by using the helper force_sig_fault. Which
takes as a parameters all of the information it needs, ensures
all of the fiddly bits of filling in struct siginfo are done properly
and then calls force_sig_info.
In short about a 5 line reduction in code for every time force_sig_info
is called, which makes the calling function clearer.
Cc: Greentime Hu <green.hu@gmail.com>
Cc: Vincent Chen <deanbo422@gmail.com>
Acked-by: Vincent Chen <deanbo422@gmail.com>
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
Call clear_siginfo to ensure every stack allocated siginfo is properly
initialized before being passed to the signal sending functions.
Note: It is not safe to depend on C initializers to initialize struct
siginfo on the stack because C is allowed to skip holes when
initializing a structure.
The initialization of struct siginfo in tracehook_report_syscall_exit
was moved from the helper user_single_step_siginfo into
tracehook_report_syscall_exit itself, to make it clear that the local
variable siginfo gets fully initialized.
In a few cases the scope of struct siginfo has been reduced to make it
clear that siginfo siginfo is not used on other paths in the function
in which it is declared.
Instances of using memset to initialize siginfo have been replaced
with calls clear_siginfo for clarity.
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
As originally committed do_revisn would deliver a siginfo for SIGILL
with an si_code composed of random stack contents. That makes no
sense and is not something userspace can depend on. So simplify
the code and just use "force_sig(SIG_ILL, current)" instead.
Fixes: 2923f5ea77 ("nds32: Exception handling")
Cc: Vincent Chen <vincentc@andestech.com>
Cc: Greentime Hu <greentime@andestech.com>
Cc: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
Neither unhandled_interrupt nor unhandled_exceptions fills in any of the
siginfo fields whend sending SIGKILL. Further because it is SIGKILL
even if all of the fields were filled out appropriately it would be impossible
for the process to read any of the siginfo fields. So simplfy things and
just use force_sig instead of force_sig_info.
Fixes: 2923f5ea77 ("nds32: Exception handling")
Cc: Vincent Chen <vincentc@andestech.com>
Cc: Greentime Hu <greentime@andestech.com>
Cc: Arnd Bergmann <arnd@arndb.de>
Acked-by: Vincent Chen <vincentc@andestech.com>
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
Use the generic dump_stack() instead of nds32 one because they are doing
the same thing.
Signed-off-by: Greentime Hu <greentime@andestech.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
This patch includes the exception/interrupt entries, pt_reg structure and
related accessors.
/* Unaligned accessing handling*/
Andes processors cannot load/store information which is not naturally
aligned on the bus, i.e., loading a 4 byte data whose start address must
be divisible by 4. If unaligned data accessing is happened, data
unaligned exception will be triggered and user will get SIGSEGV or
kernel oops according to the unaligned address. In order to make user be
able to load/store data from an unaligned address, software load/store
emulation is implemented in arch/nds32/mm/alignment.c to address data
unaligned exception.
Unaligned accessing handling is disabled by default because it is not a
normal case. User can enable this feature by following steps.
A. Compile time:
1. Enable kernel config CONFIG_ALIGNMENT_TRAP
B. Run time:
1. Enter /proc/sys/nds32/unaligned_acess folder
2. Write 1 to file enable_mode to enable unaligned accessing
handling. User can disable it by writing 0 to this file.
3. Write 1 to file debug to show which unaligned address is under
processing. User can disable it by writing 0 to this file.
However, unaligned accessing handler cannot work if this unaligned
address is not accessible such as protection violation. On this
condition, the default behaviors for addressing data unaligned exception
still happen
Signed-off-by: Vincent Chen <vincentc@andestech.com>
Signed-off-by: Greentime Hu <greentime@andestech.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>