sgp40 is a gas sensor used for measuring the air quality.
This driver is reading the raw resistance value which can be passed to
an userspace algorithm for further calculation.
The raw value is also used to calculate an estimated absolute voc index
in the range from 0 to 500. For this purpose the raw_mean value of the
resistance for which the index value is 250 might be set up as a
calibration step. This can be done with in_resistance_calibbias.
Compensation of relative humidity and temperature is supported and can
be used by writing to output values of out_humidityrelative_raw and
out_temp_raw.
There is a predecesor sensor type (sgp30) already existing. This driver
module was not extended because the new sensor is quite different in its
i2c telegrams.
Signed-off-by: Andreas Klinger <ak@it-klinger.de>
Reported-by: kernel test robot <lkp@intel.com>
Link: https://lore.kernel.org/r/20210804154641.GA3237@arbad
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Sensor has support for both i2c and serial communication interfaces.
Both offer very similar set of features. Minor differences don't impact
overall functionality like doing measurements, etc.
Support for i2c have already been added, this patch adds support
for the latter ie. serial interface.
Signed-off-by: Tomasz Duszynski <tomasz.duszynski@octakon.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Move code responsible for handling i2c communication to a separate file.
Rationale for this change is preparation for adding support for serial
communication.
Signed-off-by: Tomasz Duszynski <tomasz.duszynski@octakon.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add serial interface driver for the SCD30 sensor.
Signed-off-by: Tomasz Duszynski <tomasz.duszynski@octakon.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add I2C interface driver for the SCD30 sensor.
Signed-off-by: Tomasz Duszynski <tomasz.duszynski@octakon.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add driver for Atlas EZO line of sensors with initial support for
CO2 the sensor. This is effectively ASCII strings proxied over I2C
due to these series of sensors being by default UART.
Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
SPS30 uses triggered buffer, but the dependency is not specified in the
Kconfig file. Fix this by selecting IIO_BUFFER and IIO_TRIGGERED_BUFFER
config symbols.
Cc: stable@vger.kernel.org
Fixes: 232e0f6dde ("iio: chemical: add support for Sensirion SPS30 sensor")
Signed-off-by: Petr Štetiar <ynezz@true.cz>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
IIO triggered buffer depends on IIO buffer which is missing from Kconfig
file. This should go unnoticed most of the time because there's a
chance something else has already enabled buffers. In some rare cases
though one might experience kbuild warnings about unmet direct
dependencies and build failures due to missing symbols.
Fix this by selecting IIO_BUFFER explicitly.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Fixes: a1d642266c ("iio: chemical: add support for Plantower PMS7003 sensor")
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Add SPDX license identifiers to all Make/Kconfig files which:
- Have no license information of any form
These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:
GPL-2.0-only
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Formatting of Kconfig files doesn't look so pretty, so just
take damp cloth and clean it up.
Signed-off-by: Enrico Weigelt, metux IT consult <info@metux.net>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Without IIO_TRIGGERED_BUFFER, this driver fails to link:
drivers/iio/chemical/pms7003.o: In function `pms7003_probe':
pms7003.c:(.text+0x21c): undefined reference to `devm_iio_triggered_buffer_setup'
pms7003.c:(.text+0x21c): relocation truncated to fit: R_AARCH64_CALL26 against undefined symbol `devm_iio_triggered_buffer_setup'
Fixes: a1d642266c ("iio: chemical: add support for Plantower PMS7003 sensor")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
I clearly messed up applying this patch. Not sure
how but the entire Kconfig block is missing. This
patch puts it back as it was in the original patch.
Reported-by: Andreas Brauchli <a.brauchli@elementarea.net>
Fixes: ce51412416 ("iio: chemical: sgp30: Support Sensirion SGP30/SGPC3 sensors")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add support for Plantower PMS7003 particulate matter sensor.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add support for Sensirion SPS30 particulate matter sensor.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Bosch BME680 is a 4-in-1 sensor with temperature, pressure, humidity
and gas sensing capability. It supports both I2C and SPI communication
protocol for effective data communication.
The device supports two modes:
1. Sleep mode
2. Forced mode
The measurements only takes place when forced mode is triggered and a
single TPHG cycle is performed by the sensor. The sensor automatically
goes to sleep after afterwards.
The device has various calibration constants/parameters programmed into
devices' non-volatile memory(NVM) during production and can't be altered
by the user. These constants are used in the compensation functions to
get the required compensated readings along with the raw data. The
compensation functions/algorithms are provided by Bosch Sensortec GmbH
via their API[1]. As these don't change during the measurement cycle,
therefore we read and store them at the probe. The default configs
supplied by Bosch are also set at probe.
0-day tested with build success.
GSoC-2018: https://summerofcode.withgoogle.com/projects/#6691473790074880
Mentor: Daniel Baluta
[1] https://github.com/BoschSensortec/BME680_driver
Datasheet:
https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME680-DS001-00.pdf
Note from Jonathan: The compensation functions are 'interesting' and
could do with a tidy up in future. However, they work so we can leave that
for another day.
Cc: Daniel Baluta <daniel.baluta@nxp.com>
Signed-off-by: Himanshu Jha <himanshujha199640@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
A software trigger such as hrtimer can be used to capture the data
that will be stored in the buffer.
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: Alison Schofield <amsfield22@gmail.com>
Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add support for CCS811 VOC sensor. This patch adds support
for reading current and voltage across the sensor and TVOC
and equivalent CO2 values.
Scale and offset values have been computed according to datasheet:
- For current: raw value is in microamps
=> 0.001 scale to convert to milliamps
- For voltage: 1.65V = 1023, therefore 1650mV = 1023
=> 1650.0/1023 = 1.612903 scale to convert to millivolts
- For eCO2: raw value range is from 400ppm to 8192ppm.
=> (val - 400) * (100 - 0) / (8192 - 400) + 0 =
(val - 400) * 0.01283367 => offset: -400, scale = 0.012834
to get a percentage value
-For TVOC: raw value range is from 0ppb to 1187ppb.
=> (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 =>
scale = 0.084246 for getting a percentage value
Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: Alison Schofield <amsfield22@gmail.com>
Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The newly added atlas-ph-sensor driver uses irq_work_queue, which
may not always be enabled:
ERROR: "irq_work_queue" [drivers/iio/chemical/atlas-ph-sensor.ko] undefined!
This adds a 'select' statement to Kconfig to ensure it's there
when we need it.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Fixes: 27dec00ecf ("iio: chemical: add Atlas pH-SM sensor support")
Reviewed-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for the Atlas Scientific pH-SM chemical sensor that can
detect pH levels of solutions in the range of 0-14.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for AMS iAQ-core continuous and pulsed VOC sensors.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Add support for VZ89X sensors VOC and CO2 reporting channels in
percentage which can be converted to part per million.
Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>