While testing, it was observed that on some platforms the scale value
from iio sysfs for gyroscope is always 0 (E.g. Yoga 260). This results
in the final angular velocity component values to be zeros.
This is caused by insufficient precision of scale value displayed in sysfs.
If the precision is changed to nano from current micro, then this is
sufficient to display the scale value on this platform.
Since this can be a problem for all other HID sensors, increase scale
precision of all HID sensors to nano from current micro.
Results on Yoga 260:
name scale before scale now
--------------------------------------------
gyro_3d 0.000000 0.000000174
als 0.001000 0.001000000
magn_3d 0.000001 0.000001000
accel_3d 0.000009 0.000009806
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Neither sample frequency value nor hysteresis value can be set to be a
negative number, check and return "Invalid argument" if they are negative.
If not do this change, sample_frequency will be set into some unknown
value, read hysteresis value after write negative number will return
"Invalid argument".
Signed-off-by: Song Hongyan <hongyan.song@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio
This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.
Signed-off-by: Kweh, Hock Leong <hock.leong.kweh@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Current API only allows setting one offset in the field. This API
is extended to set multiple offsets in the field report.
Also update parameters in the users of this API.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reviewed-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Some hid sensor feature report can contain more than one reports.
This API can now support receiving multiple values from the feature
report.
Also update the parameters in the users of this API.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This fixes the following sparse warning:
CHECK drivers/iio/common/hid-sensors/hid-sensor-attributes.c
drivers/iio/common/hid-sensors/hid-sensor-attributes.c:346:5: warning:
symbol 'hid_sensor_get_reporting_interval' was not declared. Should it be static?
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Move the 'static' keyword to beginning of definition to silence the
following compilation warning:
drivers/iio/common/hid-sensors/hid-sensor-attributes.c:34:1: warning: ‘static’ is not at beginning of declaration [-Wold-style-declaration]
Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
For PROP_REPORT_INTERVAL, the spec does not mandate the presence
of the report interval unit in the feature report and expects the
default unit of measure to be used as milliseconds.
Currently, when the unit is not present, it gets set as zero leading
to issues in sampling frequency.
This patch sets the unit of measure to the default unit if it
is not defined by firmware.
Signed-off-by: Archana Patni <archana.patni@intel.com>
Signed-off-by: Subramony Sesha <subramony.sesha@intel.com>
Reviewed-by: Srinivas Pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The "i < " was missing in this condition.
Fixes: 5d02edfc39 ('iio: hid-sensors: Convert units and exponent')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Added interface to get poll value in milli-seconds. This value is
changed by changing sampling frequency. This API allows clients
to wait for at least some poll milli seconds before reading a new sample.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
HID sensor hub specify a default unit and alternative units. This
along with unit exponent can be used adjust scale. This change
change HID sensor data units to IIO defined units for each
sensor type. So in this way user space can use a simply use:
"(data + offset) * scale" to get final result.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The structure with common attributes for hid-sensors isn't specific
to the iio-subsystem, so rename it to hid_sensor_common.
Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The stuff in hid-sensor-attributes.h is needed by every piece which
uses hid-sensor-hub and merging it into hid-sensor-hub.h makes it accessible
from outside the iio subdirectory.
Signed-off-by: Alexander Holler <holler@ahsoftware.de>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This patch contains the common code, which is used by all HID sensors.
There are some common set of attributes, which every hid sensor
needs it. This patch contains all such attributes processing.
Also the trigger interface is common among all HID sensors. This
patch contains common trigger functions utilized by all HID sensors.
Signed-off-by: srinivas pandruvada <srinivas.pandruvada@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>