Commit Graph

10 Commits

Author SHA1 Message Date
Matt Ranostay 0d15190f53 iio: chemical: atlas-ph-sensor: rename atlas-ph-sensor to atlas-sensor
Since the orginal scope of the driver was to only support
the pH product from Atlas it has evolved to other sensors.

Rename the file, driver name, and regmap to atlas-sensor which
reflects this, although keep CONFIG_ATLAS_PH_SENSOR to not cause
regressions with current configurations.

Signed-off-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-12-29 15:20:06 +00:00
Thomas Gleixner ec8f24b7fa treewide: Add SPDX license identifier - Makefile/Kconfig
Add SPDX license identifiers to all Make/Kconfig files which:

 - Have no license information of any form

These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:

  GPL-2.0-only

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-21 10:50:46 +02:00
Tomasz Duszynski a1d642266c iio: chemical: add support for Plantower PMS7003 sensor
Add support for Plantower PMS7003 particulate matter sensor.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2019-02-11 20:19:33 +00:00
Andreas Brauchli ce51412416 iio: chemical: sgp30: Support Sensirion SGP30/SGPC3 sensors
Support Sensirion SGP30 and SGPC3 multi-pixel I2C gas sensors

Supported Features:

* Indoor Air Quality (IAQ) concentrations for
  - tVOC (in_concentration_voc_input)
  - CO2eq (in_concentration_co2_input) - SGP30 only

  IAQ concentrations are periodically read out by a background thread
  to allow the sensor to maintain its internal baseline.

* Gas concentration signals
  - Ethanol (in_concentration_ethanol_raw)
  - H2 (in_concentration_h2_raw) - SGP30 only

https://www.sensirion.com/file/datasheet_sgp30
https://www.sensirion.com/file/datasheet_sgpc3

Signed-off-by: Andreas Brauchli <andreas.brauchli@sensirion.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-16 14:05:58 +00:00
Tomasz Duszynski 232e0f6dde iio: chemical: add support for Sensirion SPS30 sensor
Add support for Sensirion SPS30 particulate matter sensor.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-12-16 14:05:58 +00:00
Himanshu Jha 1b3bd85927 iio: chemical: Add support for Bosch BME680 sensor
Bosch BME680 is a 4-in-1 sensor with temperature, pressure, humidity
and gas sensing capability. It supports both I2C and SPI communication
protocol for effective data communication.

The device supports two modes:

1. Sleep mode
2. Forced mode

The measurements only takes place when forced mode is triggered and a
single TPHG cycle is performed by the sensor. The sensor automatically
goes to sleep after afterwards.

The device has various calibration constants/parameters programmed into
devices' non-volatile memory(NVM) during production and can't be altered
by the user. These constants are used in the compensation functions to
get the required compensated readings along with the raw data. The
compensation functions/algorithms are provided by Bosch Sensortec GmbH
via their API[1]. As these don't change during the measurement cycle,
therefore we read and store them at the probe. The default configs
supplied by Bosch are also set at probe.

0-day tested with build success.

GSoC-2018: https://summerofcode.withgoogle.com/projects/#6691473790074880
Mentor: Daniel Baluta
[1] https://github.com/BoschSensortec/BME680_driver
Datasheet:
https://ae-bst.resource.bosch.com/media/_tech/media/datasheets/BST-BME680-DS001-00.pdf

Note from Jonathan: The compensation functions are 'interesting' and
could do with a tidy up in future.  However, they work so we can leave that
for another day.

Cc: Daniel Baluta <daniel.baluta@nxp.com>
Signed-off-by: Himanshu Jha <himanshujha199640@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2018-07-28 11:38:46 +01:00
Narcisa Ana Maria Vasile a94c24a712 iio: chemical: ccs811: Add support for AMS CCS811 VOC sensor
Add support for CCS811 VOC sensor. This patch adds support
for reading current and voltage across the sensor and TVOC
and equivalent CO2 values.

Scale and offset values have been computed according to datasheet:
    - For current: raw value is in microamps
        => 0.001 scale to convert to milliamps
    - For voltage: 1.65V = 1023, therefore 1650mV = 1023
        => 1650.0/1023 = 1.612903 scale to convert to millivolts
    - For eCO2: raw value range is from 400ppm to 8192ppm.
        => (val - 400) * (100 - 0) / (8192 - 400) + 0 =
           (val - 400) * 0.01283367 => offset: -400, scale = 0.012834
           to get a percentage value
    -For TVOC: raw value range is from 0ppb to 1187ppb.
        => (val - 0) * 100 / (1187 - 0) + 0 = val * 0.0842459 =>
            scale = 0.084246 for getting a percentage value

Cc: Daniel Baluta <daniel.baluta@gmail.com>
Cc: Alison Schofield <amsfield22@gmail.com>
Signed-off-by: Narcisa Ana Maria Vasile <narcisaanamaria12@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2017-07-22 21:16:37 +01:00
Matt Ranostay 27dec00ecf iio: chemical: add Atlas pH-SM sensor support
Add support for the Atlas Scientific pH-SM chemical sensor that can
detect pH levels of solutions in the range of 0-14.

Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2016-01-30 16:27:17 +00:00
Matt Ranostay 466df4d0c1 iio: chemical: add AMS iAQ-core support
Add support for AMS iAQ-core continuous and pulsed VOC sensors.

Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2015-12-12 15:07:38 +00:00
Matt Ranostay cd8d97774f iio: chemical: add SGX VZ89x VOC sensor support
Add support for VZ89X sensors VOC and CO2 reporting channels in
percentage which can be converted to part per million.

Signed-off-by: Matt Ranostay <mranostay@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2015-09-23 20:23:26 +01:00