o Allow hierarchical cgroup creation for blkio controller
o Currently we disallow it as both the io controller policies (throttling
as well as proportion bandwidth) do not support hierarhical accounting
and control. But the flip side is that blkio controller can not be used with
libvirt as libvirt creates a cgroup hierarchy deeper than 1 level.
<top-level-cgroup-dir>/<controller>/libvirt/qemu/<virtual-machine-groups>
o So this patch will allow creation of cgroup hierarhcy but at the backend
everything will be treated as flat. So if somebody created a an hierarchy
like as follows.
root
/ \
test1 test2
|
test3
CFQ and throttling will practically treat all groups at same level.
pivot
/ | \ \
root test1 test2 test3
o Once we have actual support for hierarchical accounting and control
then we can introduce another cgroup tunable file "blkio.use_hierarchy"
which will be 0 by default but if user wants to enforce hierarhical
control then it can be set to 1. This way there should not be any
ABI problems down the line.
o The only not so pretty part is introduction of extra file "use_hierarchy"
down the line. Kame-san had mentioned that hierarhical accounting is
expensive in memory controller hence they keep it off by default. I
suspect same will be the case for IO controller also as for each IO
completion we shall have to account IO through hierarchy up to the root.
if yes, then it probably is not a very bad idea to introduce this extra
file so that it will be used only when somebody needs it and some people
might enable hierarchy only in part of the hierarchy.
o This is how basically memory controller also uses "use_hierarhcy" and
they also allowed creation of hierarchies when actual backend support
was not available.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Acked-by: Balbir Singh <balbir@linux.vnet.ibm.com>
Reviewed-by: Gui Jianfeng <guijianfeng@cn.fujitsu.com>
Reviewed-by: Ciju Rajan K <ciju@linux.vnet.ibm.com>
Tested-by: Ciju Rajan K <ciju@linux.vnet.ibm.com>
Signed-off-by: Jens Axboe <jaxboe@fusionio.com>
* 'for-2.6.37/core' of git://git.kernel.dk/linux-2.6-block: (39 commits)
cfq-iosched: Fix a gcc 4.5 warning and put some comments
block: Turn bvec_k{un,}map_irq() into static inline functions
block: fix accounting bug on cross partition merges
block: Make the integrity mapped property a bio flag
block: Fix double free in blk_integrity_unregister
block: Ensure physical block size is unsigned int
blkio-throttle: Fix possible multiplication overflow in iops calculations
blkio-throttle: limit max iops value to UINT_MAX
blkio-throttle: There is no need to convert jiffies to milli seconds
blkio-throttle: Fix link failure failure on i386
blkio: Recalculate the throttled bio dispatch time upon throttle limit change
blkio: Add root group to td->tg_list
blkio: deletion of a cgroup was causes oops
blkio: Do not export throttle files if CONFIG_BLK_DEV_THROTTLING=n
block: set the bounce_pfn to the actual DMA limit rather than to max memory
block: revert bad fix for memory hotplug causing bounces
Fix compile error in blk-exec.c for !CONFIG_DETECT_HUNG_TASK
block: set the bounce_pfn to the actual DMA limit rather than to max memory
block: Prevent hang_check firing during long I/O
cfq: improve fsync performance for small files
...
Fix up trivial conflicts due to __rcu sparse annotation in include/linux/genhd.h
Some documentation to provide help with tunables.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Acked-by: Jeff Moyer <jmoyer@redhat.com>
Signed-off-by: Jens Axboe <jaxboe@fusionio.com>
This patch fixes few usability and configurability issues.
o All the cgroup based controller options are configurable from
"Genral Setup/Control Group Support/" menu. blkio is the only exception.
Hence make this option visible in above menu and make it configurable from
there to bring it inline with rest of the cgroup based controllers.
o Get rid of CONFIG_DEBUG_CFQ_IOSCHED.
This option currently does two things.
- Enable printing of cgroup paths in blktrace
- Enables CONFIG_DEBUG_BLK_CGROUP, which in turn displays additional stat
files in cgroup.
If we are using group scheduling, blktrace data is of not really much use
if cgroup information is not present. To get this data, currently one has to
also enable CONFIG_DEBUG_CFQ_IOSCHED, which in turn brings the overhead of
all the additional debug stat files which is not desired.
Hence, this patch moves printing of cgroup paths under
CONFIG_CFQ_GROUP_IOSCHED.
This allows us to get rid of CONFIG_DEBUG_CFQ_IOSCHED completely. Now all
the debug stat files are controlled only by CONFIG_DEBUG_BLK_CGROUP which
can be enabled through config menu.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Acked-by: Divyesh Shah <dpshah@google.com>
Reviewed-by: Gui Jianfeng <guijianfeng@cn.fujitsu.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
Here is the document for blkio.weight_device
Signed-off-by: Gui Jianfeng <guijianfeng@cn.fujitsu.com>
Acked-by: Vivek Goyal <vgoyal@redhat.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
1) group_wait_time - This is the amount of time the cgroup had to wait to get a
timeslice for one of its queues from when it became busy, i.e., went from 0
to 1 request queued. This is different from the io_wait_time which is the
cumulative total of the amount of time spent by each IO in that cgroup waiting
in the scheduler queue. This stat is a great way to find out any jobs in the
fleet that are being starved or waiting for longer than what is expected (due
to an IO controller bug or any other issue).
2) empty_time - This is the amount of time a cgroup spends w/o any pending
requests. This stat is useful when a job does not seem to be able to use its
assigned disk share by helping check if that is happening due to an IO
controller bug or because the job is not submitting enough IOs.
3) idle_time - This is the amount of time spent by the IO scheduler idling
for a given cgroup in anticipation of a better request than the exising ones
from other queues/cgroups.
All these stats are recorded using start and stop events. When reading these
stats, we do not add the delta between the current time and the last start time
if we're between the start and stop events. We avoid doing this to make sure
that these numbers are always monotonically increasing when read. Since we're
using sched_clock() which may use the tsc as its source, it may induce some
inconsistency (due to tsc resync across cpus) if we included the current delta.
Signed-off-by: Divyesh Shah<dpshah@google.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
These stats are useful for getting a feel for the queue depth of the cgroup,
i.e., how filled up its queues are at a given instant and over the existence of
the cgroup. This ability is useful when debugging problems in the wild as it
helps understand the application's IO pattern w/o having to read through the
userspace code (coz its tedious or just not available) or w/o the ability
to run blktrace (since you may not have root access and/or not want to disturb
performance).
Signed-off-by: Divyesh Shah<dpshah@google.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
This includes both the number of bios merged into requests belonging to this
cgroup as well as the number of requests merged together.
In the past, we've observed different merging behavior across upstream kernels,
some by design some actual bugs. This stat helps a lot in debugging such
problems when applications report decreased throughput with a new kernel
version.
This needed adding an extra elevator function to capture bios being merged as I
did not want to pollute elevator code with blkiocg knowledge and hence needed
the accounting invocation to come from CFQ.
Signed-off-by: Divyesh Shah<dpshah@google.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
that include some minor fixes and addresses all comments.
Changelog: (most based on Vivek Goyal's comments)
o renamed blkiocg_reset_write to blkiocg_reset_stats
o more clarification in the documentation on io_service_time and io_wait_time
o Initialize blkg->stats_lock
o rename io_add_stat to blkio_add_stat and declare it static
o use bool for direction and sync
o derive direction and sync info from existing rq methods
o use 12 for major:minor string length
o define io_service_time better to cover the NCQ case
o add a separate reset_stats interface
o make the indexed stats a 2d array to simplify macro and function pointer code
o blkio.time now exports in jiffies as before
o Added stats description in patch description and
Documentation/cgroup/blkio-controller.txt
o Prefix all stats functions with blkio and make them static as applicable
o replace IO_TYPE_MAX with IO_TYPE_TOTAL
o Moved #define constant to top of blk-cgroup.c
o Pass dev_t around instead of char *
o Add note to documentation file about resetting stats
o use BLK_CGROUP_MODULE in addition to BLK_CGROUP config option in #ifdef
statements
o Avoid struct request specific knowledge in blk-cgroup. blk-cgroup.h now has
rq_direction() and rq_sync() functions which are used by CFQ and when using
io-controller at a higher level, bio_* functions can be added.
Signed-off-by: Divyesh Shah<dpshah@google.com>
Signed-off-by: Jens Axboe <jens.axboe@oracle.com>