For INT3403 sensor PTYP field is mandatory. But some platforms didn't
have this field for sensors. This cause load failure for int3403 driver.
This change checks for the presence of _TMP method and if present, then
treats this device as a sensor.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
When ACPI sends notification for trip point change re-read trips and
notify thermal core, so that this can be passed to user space thermal
controller.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Separated the code for reading trip points from int340x_thermal_zone_add to
a standalone function int340x_thermal_read_trips. This standlone
interface to read is exported so that int340x drivers can re-read trips
on ACPI notification for trip point change.
Also the appropriate notification events are sent by int340x driver based
on the acpi event using int340x_thermal_zone_device_update().
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Using APIs from int340x thermal zone module to add and remove thermal
zones.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
drivers/thermal/int340x_thermal/int3403_thermal.c:468:3-8: No need to set .owner here. The core will do it.
Remove .owner field if calls are used which set it automatically
Generated by: scripts/coccinelle/api/platform_no_drv_owner.cocci
Signed-off-by: Fengguang Wu <fengguang.wu@intel.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
The thermal_zone_device_unregister() function tests whether its argument
is NULL and then returns immediately. Thus the test around the call
is not needed.
This issue was detected by using the Coccinelle software.
Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Thermal hysteresis represents a temperature difference.
But the original code treats it as a temperature value,
Convert it from tenths of degree Kelvin to Milli-Celsius
by deducing 273200. This is not right.
Kelvin and Celsius have same degree size. From temperature
difference view, the conversion between tenths of degree
Kelvin unit and Milli-Celsius unit is just to multiply 100.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
ACPI INT3403 device object can be used to retrieve temperature date
from temperature sensors present in the system, and to expose
device' performance control.
The previous INT3403 thermal driver supports temperature reporting only,
thus remove it and introduce this new & enhanced one.
Signed-off-by: Lan Tianyu <tianyu.lan@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>