According to the datasheet available at (1), the bottom four
bits are always zero and the actual voltage is 1.25x this value
in mV. Since the kernel API specifies that voltages should be in
uV, it should report 1250x the shifted value.
1) https://datasheets.maximintegrated.com/en/ds/MAX17040-MAX17041.pdf
Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Notify core through power_supply_changed() in case of changes in state
of charge and power supply status. This is useful for user-space to
efficiently update current battery level.
Signed-off-by: Matheus Castello <matheus@castello.eng.br>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
For configuration of fuel gauge alert for a low level state of charge
interrupt we add a function to config level threshold and a device tree
binding property to set it in flatned device tree node.
Now we can use "maxim,alert-low-soc-level" property with the values from
1% up to 32% to configure alert interrupt threshold.
Signed-off-by: Matheus Castello <matheus@castello.eng.br>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
According datasheet max17040 has a pin for alert host for low SOC.
This pin can be used as external interrupt, so we need to check for
interrupts assigned for device and handle it.
In handler we are checking and storing fuel gauge registers values
and send an uevent to notificate user space, so user space can decide
save work or turn off since the alert demonstrate that the battery may
no have the power to keep the system turned on for much longer.
Signed-off-by: Matheus Castello <matheus@castello.eng.br>
Reviewed-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We have a dedicated pointer for that, so use it. Much easier to read and
less computation involved.
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Replace GPL v2.0 and v2.0+ license statements with SPDX license
identifiers.
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The driver doesn't have a struct of_device_id table but supported devices
are registered via Device Trees. This is working on the assumption that a
I2C device registered via OF will always match a legacy I2C device ID and
that the MODALIAS reported will always be of the form i2c:<device>.
But this could change in the future so the correct approach is to have an
OF device ID table if the devices are registered via OF.
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
According to the datasheet, MAX17040 has six 16-bit registers.
Register reads and writes are only valid if all 16 bits are transferred.
Any write command that is terminated early is ignored.
So it's better to change register transacton length from 8 bits to 16 bits.
Signed-off-by: Liu Xiang <liu.xiang6@zte.com.cn>
Signed-off-by: Sebastian Reichel <sre@kernel.org>
This moves all power supply drivers from drivers/power/
to drivers/power/supply/. The intention is a cleaner
source tree, since drivers/power/ also contains frameworks
unrelated to power supply, like adaptive voltage scaling.
Signed-off-by: Sebastian Reichel <sre@kernel.org>