The cdn_dp_pd_event_work is using drm_helper_hpd_irq_event to update the
connector status, this function is used to update all connectors of
drm_device. Therefore, the detect of other connector will be call, when
cdn_dp_pd_event_work is triggered, every time. It is not necessary, and
it may cause system crash. replace drm_helper_hpd_irq_event with
drm_kms_helper_hotplug_event, only update cdn-dp status.
Signed-off-by: Chris Zhong <zyw@rock-chips.com>
Tested-by: Guenter Roeck <groeck@chromium.org>
Reviewed-by: Guenter Roeck <groeck@chromium.org>
If the driver is in suspended mode, the dp block may be disabled, and
chip registers may not be accessible. Yet, the worker may be triggered
in this situation by an extcon event. If that happens, the following crash
will be seen.
cdn-dp fec00000.dp: [drm:cdn_dp_pd_event_work] *ERROR* Enable dp failed -19
cdn-dp fec00000.dp: [drm:cdn_dp_pd_event_work] Connected, not enabled. Enabling cdn
Bad mode in Error handler detected, code 0xbf000002 -- SError
CPU: 1 PID: 10357 Comm: kworker/1:2 Not tainted 4.4.21-05903-ge0514ea #1
Hardware name: Google Kevin (DT)
Workqueue: events cdn_dp_pd_event_work
task: ffffffc0cda67080 ti: ffffffc0b9b80000 task.ti: ffffffc0b9b80000
PC is at cdn_dp_clock_reset+0x30/0xa8
LR is at cdn_dp_enable+0x1e0/0x69c
...
Call trace:
[<ffffffc0005a7e24>] cdn_dp_pd_event_work+0x58/0x3f4
[<ffffffc0002397f0>] process_one_work+0x240/0x424
[<ffffffc00023a28c>] worker_thread+0x2fc/0x424
[<ffffffc00023f5fc>] kthread+0x10c/0x114
[<ffffffc000203dd0>] ret_from_fork+0x10/0x40
Problem is two-fold: The worker should not run while suspended, and the
suspend function should not call cdn_dp_disable() while the worker is
running.
Signed-off-by: Guenter Roeck <groeck@chromium.org>
Signed-off-by: Sean Paul <seanpaul@chromium.org>
Signed-off-by: Chris Zhong <zyw@rock-chips.com>
If no monitor is connected, suspend/resume cycles result in firmware
load errors because the driver attempts to load the firmware while
the system is in suspend state. This results in a kernel warning and
traceback.
Loading the firmware during boot fixes the problem. Note that we can not
just call schedule_work conditionally in cdn_dp_pd_event() if the insertion
status changed. The problem would still be seen if a monitor is connected
for the first time during suspend.
Signed-off-by: Guenter Roeck <groeck@chromium.org>
Signed-off-by: Sean Paul <seanpaul@chromium.org>
Signed-off-by: Chris Zhong <zyw@rock-chips.com>
Add support for cdn DP controller which is embedded in the rk3399
SoCs. The DP is compliant with DisplayPort Specification,
Version 1.3, This IP is compatible with the rockchip type-c PHY IP.
There is a uCPU in DP controller, it need a firmware to work,
please put the firmware file to /lib/firmware/rockchip/dptx.bin. The
uCPU in charge of aux communication and link training, the host use
mailbox to communicate with the ucpu.
The dclk pin_pol of vop must not be invert for DP.
Signed-off-by: Chris Zhong <zyw@rock-chips.com>
[seanpaul fixed up some races between the worker and modeset]
[seanpaul squashed ~15 commits from chromium.org gerrit]
Signed-off-by: Sean Paul <seanpaul@chromium.org>
[groeck fixed compilation errors when building as module]
Signed-off-by: Guenter Roeck <groeck@chromium.org>