pr_err() messages should end with a new-line to avoid other messages being
concatenated.
Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Reviewed-by: Andreas Färber <afaerber@suse.de>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
The Actions Semi S500 SoC provides four timers, 2Hz0/1 and 32-bit TIMER0/1.
Use TIMER0 as clocksource and TIMER1 as clockevents.
Based on LeMaker linux-actions tree.
An S500 datasheet can be found on the LeMaker Guitar pages:
http://www.lemaker.org/product-guitar-download-29.html
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Andreas Färber <afaerber@suse.de>