The newer 2711 and 7211 chips have two PWM controllers and failure to
dynamically allocate the PWM base would prevent the second PWM
controller instance being probed for succeeding with an -EEXIST error
from alloc_pwms().
Fixes: e5a06dc5ac ("pwm: Add BCM2835 PWM driver")
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Reviewed-by: Nicolas Saenz Julienne <nsaenzjulienne@suse.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This suppresses error messages in case the PWM clock isn't ready yet.
Signed-off-by: Stefan Wahren <wahrenst@gmx.net>
Reviewed-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
The range check for period_ns was written under assumption of a fixed
PWM clock. With clk-bcm2835 driver the PWM clock is a dynamic one.
So fix this by doing the range check on the period register value.
Signed-off-by: Stefan Wahren <wahrenst@gmx.net>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
The PWM config can be triggered via sysfs, so we better suppress the
error message in case of an invalid period to avoid kernel log spamming.
Signed-off-by: Stefan Wahren <wahrenst@gmx.net>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
If sending IR with carrier of 455kHz using the pwm-ir-tx driver, the
carrier ends up being 476kHz. The clock is set to bcm2835-pwm with a
rate of 10MHz.
A carrier of 455kHz has a period of 2198ns, but the arithmetic truncates
this to 2100ns rather than 2200ns. So, use DIV_ROUND_CLOSEST() to reduce
rounding errors, and we have a much more accurate carrier of 454.5kHz.
Reported-by: Andreas Christ <andreas@christ-faesch.ch>
Signed-off-by: Sean Young <sean@mess.org>
Acked-by: Stefan Wahren <wahrenst@gmx.net>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This adds support for the third (optional) pwm cell to specify the
polarity, which is needed by display backlights for example.
Signed-off-by: Stefan Wahren <stefan.wahren@i2se.com>
Reviewed-by: Eric Anholt <eric@anholt.net>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
It's possible that the PWM clock becomes an orphan. So better check the
result of clk_get_rate() in order to prevent a division by zero.
Signed-off-by: Stefan Wahren <stefan.wahren@i2se.com>
Reviewed-by: Eric Anholt <eric@anholt.net>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Currently pwm-bcm2835 assumes a fixed clock rate and stores the
resulting scaler in the driver structure. But with the upcoming
PWM clock support for clk-bcm2835 the rate could change, so
calculate the scaler in the ->config() callback.
Signed-off-by: Stefan Wahren <stefan.wahren@i2se.com>
Reviewed-by: Eric Anholt <eric@anholt.net>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>