Since commit 84af7a6194 ("checkpatch: kconfig: prefer 'help' over
'---help---'"), the number of '---help---' has been gradually
decreasing, but there are still more than 2400 instances.
This commit finishes the conversion. While I touched the lines,
I also fixed the indentation.
There are a variety of indentation styles found.
a) 4 spaces + '---help---'
b) 7 spaces + '---help---'
c) 8 spaces + '---help---'
d) 1 space + 1 tab + '---help---'
e) 1 tab + '---help---' (correct indentation)
f) 1 tab + 1 space + '---help---'
g) 1 tab + 2 spaces + '---help---'
In order to convert all of them to 1 tab + 'help', I ran the
following commend:
$ find . -name 'Kconfig*' | xargs sed -i 's/^[[:space:]]*---help---/\thelp/'
Signed-off-by: Masahiro Yamada <masahiroy@kernel.org>
Add SPDX license identifiers to all Make/Kconfig files which:
- Have no license information of any form
These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:
GPL-2.0-only
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
The only driver based on MSCAN at the moment is for PPC machines,
so it makes no sense to present the menu on M68K. The menu will always
be empty there.
Signed-off-by: Jean Delvare <jdelvare@suse.de>
Cc: Wolfgang Grandegger <wg@grandegger.com>
Cc: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
This patch adds an 'if CAN_DEV...endif' Block around the CAN driver
symbols in drivers/net/can/Kconfig. So the 'depends on CAN' dependencies
can be removed.
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
The main differences compared to the MSCAN on the MPC5200 are:
- More flexibility in choosing the CAN source clock and frequency:
Three different clock sources can be selected: "ip", "ref" or "sys".
For the latter two, a clock divider can be defined as well. If the
clock source is not specified by the device tree, we first try to
find an optimal CAN source clock based on the system clock. If that
is not possible, the reference clock will be used.
- The behavior of bus-off recovery is configurable:
To comply with the usual handling of Socket-CAN bus-off recovery,
"recovery on request" is selected (instead of automatic recovery).
Note that only MPC5121 Rev. 2 and later is supported.
Signed-off-by: Wolfgang Grandegger <wg@denx.de>
Reviewed-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
- move Kconfig entries to the subdirectory
- do remaining renames of mpc52xx to mpc5xxx
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>