With commit 132f2d45fb ("can: c_can: add support to 64 message
objects") the number of message objects used for reception /
transmission depends on FIFO size.
The ethtools API support allows you to retrieve this info. Driver info
has been added too.
Link: https://lore.kernel.org/r/20210514165549.14365-2-dariobin@libero.it
Signed-off-by: Dario Binacchi <dariobin@libero.it>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Add SPDX license identifiers to all Make/Kconfig files which:
- Have no license information of any form
These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:
GPL-2.0-only
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
No need to manually copy debug settings into subdir Makefiles. kbuild
has a mechanism for inheriting, so let's use it.
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Bosch C_CAN controller is a full-CAN implementation which is compliant
to CAN protocol version 2.0 part A and B. Bosch C_CAN user manual can be
obtained from:
http://www.semiconductors.bosch.de/media/en/pdf/ipmodules_1/c_can/users_manual_c_can.pdf
This patch adds the support for this controller.
The following are the design choices made while writing the controller
driver:
1. Interface Register set IF1 has be used only in the current design.
2. Out of the 32 Message objects available, 16 are kept aside for RX
purposes and the rest for TX purposes.
3. NAPI implementation is such that both the TX and RX paths function
in polling mode.
Signed-off-by: Bhupesh Sharma <bhupesh.sharma@st.com>