This change adds support for the Analog Devices Generic AXI ADC IP core.
The IP core is used for interfacing with analog-to-digital (ADC) converters
that require either a high-speed serial interface (JESD204B/C) or a source
synchronous parallel interface (LVDS/CMOS).
Usually, some other interface type (i.e SPI) is used as a control interface
for the actual ADC, while the IP core (controlled via this driver), will
interface to the data-lines of the ADC and handle the streaming of data
into memory via DMA.
Because of this, the AXI ADC driver needs the other SPI-ADC driver to
register with it. The SPI-ADC needs to be register via the SPI framework,
while the AXI ADC registers as a platform driver. The two cannot be ordered
in a hierarchy as both drivers have their own registers, and trying to
organize this [in a hierarchy becomes] problematic when trying to map
memory/registers.
There are some modes where the AXI ADC can operate as standalone ADC, but
those will be implemented at a later point in time.
DocLink: https://wiki.analog.com/resources/fpga/docs/axi_adc_ip
Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Now that all channel SigmaDelta IIO channel macros have been localized,
remove the generic ones.
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Before this patch the ad_sigma_delta implementation hardcoded
the irq trigger type to low, assuming that all Sigma-Delta ADCs
have the same interrupt-type.
This patch allows all drivers using the ad_sigma_delta layer to set the
irq trigger type to the one specified in the datasheet.
Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch exports the ad_sd_calibrate function in order to be able to
call it from outside ad_sigma_delta.
There are cases where the option to calibrate one channel at a time is
necessary (ex. system calibration for zero scale and full scale).
Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Based on 1 normalized pattern(s):
licensed under the gpl 2
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 135 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Allison Randal <allison@lohutok.net>
Reviewed-by: Richard Fontana <rfontana@redhat.com>
Reviewed-by: Alexios Zavras <alexios.zavras@intel.com>
Reviewed-by: Steve Winslow <swinslow@gmail.com>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190528170026.071193225@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
For devices from the SigmaDelta family we need to keep CS low when doing a
conversion, since the device will use the MISO line as a interrupt to
indicate that the conversion is complete.
This is why the driver locks the SPI bus and when the SPI bus is locked
keeps as long as a conversion is going on. The current implementation gets
one small detail wrong though. CS is only de-asserted after the SPI bus is
unlocked. This means it is possible for a different SPI device on the same
bus to send a message which would be wrongfully be addressed to the
SigmaDelta device as well. Make sure that the last SPI transfer that is
done while holding the SPI bus lock de-asserts the CS signal.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Alexandru Ardelean <Alexandru.Ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Some newer devices from the Sigma-Delta ADC family do have their data
register at a different address than the current default address. Add a
parameter to the ad_sigma_delta_info struct which allows to override the
default address.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Fix the following sparse warnings:
CHECK drivers/iio/adc/stm32-dfsdm-adc.c
symbol 'stm32_dfsdm_get_buff_cb' was not declared. Should it be static?
symbol 'stm32_dfsdm_release_buff_cb' was not declared. Should it be static?
BTW, move interrupt.h to sort headers alphabetically.
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The `ad7780` driver does not implement setting/getting the sampling
frequency.
For the ad7780/ad7781 devices, the control is done via an external pin,
and the ad7170/ad7171 devices have a fixed sampling rate (so, no control).
For these devices, and similar other that may be added later on,
a AD_SD_CHANNEL_NO_SAMPLE_FREQ() macro has been added, which doesn't set
the IIO_CHAN_INFO_SAMP_FREQ flag.
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This code offers a way to handle PDM audio microphones in
ASOC framework. Audio driver should use consumer API.
A specific management is implemented for DMA, with a
callback, to allows to handle audio buffers efficiently.
Signed-off-by: Arnaud Pouliquen <arnaud.pouliquen@st.com>
Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Since most of the SD ADCs have the option of reseting the serial
interface by sending a number of SCLKs with CS = 0 and DIN = 1,
a dedicated function that can do this is usefull.
Needed for the patch: iio: ad7793: Fix the serial interface reset
Signed-off-by: Dragos Bogdan <dragos.bogdan@analog.com>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This driver predates the availability of IIO_CHAN_INFO_SAMP_FREQ
attribute wherein usage has some advantages like it can be accessed by
in-kernel consumers as well as reduces the code size.
Therefore, use IIO_CHAN_INFO_SAMP_FREQ to implement the
sampling_frequency attribute instead of using IIO_DEV_ATTR_SAMP_FREQ()
macro.
Move code from the functions associated with IIO_DEV_ATTR_SAMP_FREQ()
into respective read and write hooks with the mask set to
IIO_CHAN_INFO_SAMP_FREQ.
Signed-off-by: Eva Rachel Retuya <eraretuya@gmail.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
The original info_mask is going away in favour of the broken out versions.
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Acked-by: Lars-Peter Clausen <lars@metafoo.de>
Most devices from the Analog Devices Sigma Delta family use a similar scheme for
communication with the device. This includes register access, as well as trigger
handling. But each device sub-family has different features and different
register layouts (some even have no registers at all) and thus it is impractical
to try to support all of the devices by the same driver. This patch adds a
common base library for Sigma Delta converter devices. It will be used by
individual drivers.
This code is mostly based on the three existing Sigma Delta drivers the AD7192,
AD7780 and AD7793, but has been improved for more robustness and flexibility.
Signed-off-by: Lars-Peter Clausen <lars@metafoo.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>