Remove the global driver work queue and replace it with a workqueue
local to the adapter. The usage of this workqueue makes this the
correct place for the structure. In addition multiple adapters won't
block each other due to the serialization of the queued work.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The flag ZFCP_REQ_AUTO_CLEANUP was useless as the
ZFCP_STATUS_FSFREQ_CLEANUP flag is there for exactly the same purpose.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Remove the special case for NO_QTCB requests and optimize the
mempool and cache processing for fsfreqs. Especially use seperate
mempools for the zfcp_fsf_req and zfcp_qtcb structs.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The combination wait_queue/wakeup in conjunction with the flag
ZFCP_STATUS_FSFREQ_COMPLETED to signal the completion of an fsfreq
was not race-safe and can be better solved by a completion.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There is no need for the QDIO layer to have knowledge or do things
wich are done better by the FSF layer and vice versa. Straighten a
few things to improve vividness.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
An adapter shutdown implicitly closes all open ports. Make sure to
mark all WKA ports as offline, not only the directory server. Also
make sure that no pending wka port work is running when the adapter is
being removed.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When the FCP channel returns a series of commands with the error
status "test link", zfcp will send a series of ELS ADISC commands.
This is technically no problem, but it is enough to only issue one
test command per remote port. So, track whether a ELS ADISC command is
already pending, and do not send a new one if there is already a
pending command.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Using a bitwise OR to not set anything at all is pointless so remove
the useless statement.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The default trace level is to only trace failed FSF commands. Thus it
is not necessary to collect trace data for most FSF commands, since
it will be thrown away later. Restructure the FSF/HBA trace
infrastructure to first check the trace level in a inline function and
only do the expensive data collection for matching trace levels.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The default trace level is to only trace failed SCSI commands. Thus it
is not necessary to collect trace data for most SCSI commands since it
will be thrown away later. Restructure the SCSI trace infrastructure
to first check the trace level in a inline function and only do the
expensive data collection for matching trace levels.
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The struct zfcp_adapter includes everything related to the debug
traces. This introduces dependences between the definitions in
zfcp_def.h and zfcp_dbf.h. Move all debug related data structures to a
new data structure to break those dependencies and manage the debug
data in zfcp_dbf.[hc].
Reviewed-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In certain error scenarios ports, rports are getting attached,
validated and removed from the systems environment. Depending on the
layer this occurs asynchronously. This patch fixes the few races
which existed and ensures all references and cross references are
cleared at the time they're invalid. In addition fc transports
actions are only scheduled when required.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch is to add DM support for next generation of Dell PowerVault
storage array.
Signed-off-by: Yanqing Liu <Yanqing_Liu@Dell.com>
Acked-by: Chandra Seetharaman <sekharan@us.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Do not set max_id value received from FW. Once SAS transport layer is
introduced max_id value is missleading to SCSI mid layer. Use max_id to
infinite value.
logic of can queue of scsi host is changed.
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Universally, SCSI functions assume the lengths fed in are those of the buffer
to DMA data to, not the lengths of the data minus the header.
scsi_vpd_inquiry() assumed the latter and got it wrong, so fix up all the
functions to use the correct assumption (and fix a bug where INQUIRY in SCSI-2
dcannot go over 255).
[jejb: Matthew posted an identical version of this at the same time I did]
Signed-off-by: Matthew Wilcox <matthew@wil.cx>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
An IBM tape drive failed to complete a PERSISTENT RESERVE IN within the scsi
cmd timeout. Error recovery was initiated and it sequenced from abort through
taking the tape drive offline.
The device was taken offline because it repeatedly responded to the TUR command
issued by error recovery with a RESERVATION CONFLICT status. The tape drive
was reserved to another system. This is perfectly legitimate response to TUR,
and is one that an escalation of recovery is unlikely to clear. Further,
escalation of recovery can have undesirable side effects on the operation of
tape drives shared with other initiators.
Instead of escalating recovery, error recovery should treat the RESERVATION
CONFLICT response to the TUR as a good status, giving the issuer of the
command the opportunity to handle the timeout and reservation conflict.
Signed-off-by: Michael reed <mdr@sgi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In nsp_cs_config there is a wrong struct nsp_cs_configdata allocation.
It allocates only sizeof(pointer to nsp_cs_configdata) for a whole
structure. Add a dereference to the sizeof to allocate
sizeof(nsp_cs_configdata).
Signed-off-by: Jiri Slaby <jirislaby@gmail.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The allocated struct is manually zeroed after allocation, so avoid using
the (broken) kzalloc mempool (which does not re-zero previously used items
when they are returned to the pool).
Acked-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: Sage Weil <sage@newdream.net>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When the multiqueue mode fails to work, the driver falls back on single
queue mode. This ensures that the firmware is reinitialized with single
queue options and all the resources are readjusted accordingly.
Signed-off-by: Anirban Chakraborty <anirban.chakraborty@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The interrupt handler clears the interrupt status register for response
updates in the base queue while working in the multique mode. This could lead
to missing interrupt for async events, mail box completions etc. as these are
also handled in the base queue. The fix ensures that the interrupt bit is not
cleared for response updates in the ISR when the driver is working in
multiqueue mode.
Signed-off-by: Anirban Chakraborty <anirban.chakraborty@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
One byte added to make the IOCB structure satisfy
size requirements.
Signed-off-by: Shyam Sundar <shyam.sundar@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If vports are created and topology is changed to Loop only, the
driver continuously gets a LIP reset occurred and keeps trying to
enable the vport. Only manage requests during F_Port.
Signed-off-by: Lalit Chandivade <lalit.chandivade@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The RSCN processing is skipped if the event received is global and vha is not recipient.
Signed-off-by: Santosh Vernekar <santosh.vernekar@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Treat a global port-unavailable PORT_UPDATE (8014h) AEN as a
loop-down event. For this case, within the FCoE domain, the
'logical' interface has been terminated, but the driver will
not receive the classic LOOP_DOWN AEN.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Use scsi_dh_set_params() set parameters provided. Save the parameters in
parse_hw_handler() and use it in parse_path().
Reported-by: Eddie Williams <Eddie.Williams@steeleye.com>
Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com>
Tested-by: Eddie Williams <Eddie.Williams@steeleye.com>
Cc: Alasdair G Kergon <agk@redhat.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Handle the parameters provided by user thru multipath.
This handler expects only 2 parameters and their value can either be 0 or 1.
This code originates from the old dm-emc.c file. Appropriate changes have
been made to make it work in the new design.
Reported-by: Eddie Williams <Eddie.Williams@steeleye.com>
Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com>
Tested-by: Eddie Williams <Eddie.Williams@steeleye.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When we moved the device handler functionality from dm layer to SCSI layer
we dropped the parameter functionality.
This path adds an interface to scsi dh layer to set device handler
parameters.
Basically, multipath layer need to create a string with all the parameters
and call scsi_dh_set_params() after it called scsi_dh_attach() on a
device.
If a device handler provides such an interface it will handle the parameters
as it expects them.
Reported-by: Eddie Williams <Eddie.Williams@steeleye.com>
Signed-off-by: Chandra Seetharaman <sekharan@us.ibm.com>
Tested-by: Eddie Williams <Eddie.Williams@steeleye.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Now that hot add works correctly, if a new device is added, we're still
operating on stale enclosure data, so fix that by updating the enclosure
diagnostic pages when we get notified of a device hot add
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Right at the moment, hot removal of a device within an enclosure does
nothing (because the intf_remove only copes with enclosure removal not
with component removal). Fix this by adding a function to remove the
component. Also needed to fix the prototype of
enclosure_remove_device, since we know the device we've removed but
not the internal component number
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In a situation either with expanders or with multiple enclosure
devices, hot add doesn't always work. This is because we try to find
a single enclosure device attached to the host. Fix this by looping
over all enclosure devices attached to the host and also by making the
find loop recognise that the enclosure devices may be expander remote
(i.e. not parented by the host).
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
ipr_cmd_label[] isn't big enough for an eight byte string plus terminator.
Fix by shortening the string to seven bytes.
Signed-off-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When bnx2i_adapter_ready() fails, connection handle(cid) = 0 is wrongly freed
because 'cid' is not yet allocated for the endpoint. Fix is to initialize
bnx2i_ep->ep_iscsi_cid to '-1' in bnx2i_alloc_ep() and not in
bnx2i_ep_connect() to avoid releasing invalid 'cid'. There is already a check
in bnx2i_free_iscsi_cid() not to free invalid iscsi connection handle (-1)
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Without the fix bnx2i would fail tt->xmit_task() when link is down and
libiscsi would have already incremented session->cmdsn before calling bnx2i's
xmit_task() entry point and will just return the command to SCSI-ML when
xmit_task() fails. libiscsi does not retract the session->cmdsn as the command
was never sent on wire. It is generally good idea for LLD, bnx2i to accept
the scsi cmnd/nopout and let upper layer timeout and go though normal session
recovery process. When link is down, unsolicited nopout will not be accepted
by bnx2i and connection will never enter recovery state. This fix is required
for MPIO to work corectly
Signed-off-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The phys_dev was used only to locate common offload EM instance for all
FCoE instances on a eth devices in function fcoe_em_config, so just updated
fcoe_em_config to look for actual real eth device in locating common offload
EM instance and then no need to store phys_dev in fcoe_softc, so removes
phys_dev from fcoe_softc also.
Renames fcoe_softc real_dev to netdev and updates all its uses to use netdev.
So effectively no functional change, use of single netdev instead phys_dev
and real_dev saves one pointer memory in fcoe_softc, also real_dev used here
was confusing with vlan driver terminology since real_dev in vlan driver is
referred to physical eth device.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
I don't believe this check is needed any more in the current kernel, which,
if I understand correctly, is for compound page where only the first page
is supposed to get ref-counted.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
FC_FRAME_SG_LEN is 4 which is too small when offload is enabled. Actually, the
WARN_ON() in fc_fcp_send_data() should be:
WARN_ON(skb_shinfo(fp_skb(fp))->nr_frags > MAX_SKB_FRAGS);
But since we will not get anything more than 64K anyway, so there is no need
to do this anyway here. Therefore, I am getting rid of FC_FRAME_SG_LEN here
and the WARN_ON here.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>