Commit Graph

101 Commits

Author SHA1 Message Date
Petr Machata 169327d585 net: bridge: Propagate extack to switchdev
ndo_bridge_setlink has been updated in the previous patch to have extack
available, and changelink RTNL op has had this argument since the time
extack was added. Propagate both through the bridge driver to eventually
reach br_switchdev_port_vlan_add(), where it will be used by subsequent
patches.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Acked-by: Jiri Pirko <jiri@mellanox.com>
Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Acked-by: Ivan Vecera <ivecera@redhat.com>
Acked-by: Roopa Prabhu <roopa@cumulusnetworks.com>
Reviewed-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-12-12 16:34:21 -08:00
Ido Schimmel 5a6db04ca8 net: bridge: Extend br_vlan_get_pvid() for bridge ports
Currently, the function only works for the bridge device itself, but
subsequent patches will need to be able to query the PVID of a given
bridge port, so extend the function.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Reviewed-by: Petr Machata <petrm@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-30 17:06:28 -08:00
David S. Miller f2be6d710d Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net 2018-11-19 10:55:00 -08:00
Nikolay Aleksandrov 9d332e69c1 net: bridge: fix vlan stats use-after-free on destruction
Syzbot reported a use-after-free of the global vlan context on port vlan
destruction. When I added per-port vlan stats I missed the fact that the
global vlan context can be freed before the per-port vlan rcu callback.
There're a few different ways to deal with this, I've chosen to add a
new private flag that is set only when per-port stats are allocated so
we can directly check it on destruction without dereferencing the global
context at all. The new field in net_bridge_vlan uses a hole.

v2: cosmetic change, move the check to br_process_vlan_info where the
    other checks are done
v3: add change log in the patch, add private (in-kernel only) flags in a
    hole in net_bridge_vlan struct and use that instead of mixing
    user-space flags with private flags

Fixes: 9163a0fc1f ("net: bridge: add support for per-port vlan stats")
Reported-by: syzbot+04681da557a0e49a52e5@syzkaller.appspotmail.com
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-17 21:38:44 -08:00
Michał Mirosław 5978f8a9fb bridge: use __vlan_hwaccel helpers
This removes assumption than vlan_tci != 0 when tag is present.

Signed-off-by: Michał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-08 20:45:04 -08:00
Li RongQing 1a3aea2534 net: bridge: fix a possible memory leak in __vlan_add
After per-port vlan stats, vlan stats should be released
when fail to add vlan

Fixes: 9163a0fc1f ("net: bridge: add support for per-port vlan stats")
CC: bridge@lists.linux-foundation.org
cc: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
CC: Roopa Prabhu <roopa@cumulusnetworks.com>
Signed-off-by: Zhang Yu <zhangyu31@baidu.com>
Signed-off-by: Li RongQing <lirongqing@baidu.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-10-15 22:53:52 -07:00
Nikolay Aleksandrov 9163a0fc1f net: bridge: add support for per-port vlan stats
This patch adds an option to have per-port vlan stats instead of the
default global stats. The option can be set only when there are no port
vlans in the bridge since we need to allocate the stats if it is set
when vlans are being added to ports (and respectively free them
when being deleted). Also bump RTNL_MAX_TYPE as the bridge is the
largest user of options. The current stats design allows us to add
these without any changes to the fast-path, it all comes down to
the per-vlan stats pointer which, if this option is enabled, will
be allocated for each port vlan instead of using the global bridge-wide
one.

CC: bridge@lists.linux-foundation.org
CC: Roopa Prabhu <roopa@cumulusnetworks.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-10-12 10:18:58 -07:00
Nikolay Aleksandrov be3664a038 net: bridge: convert group_addr_set option to a bit
Convert group_addr_set internal bridge opt to a bit.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Stephen Hemminger <stephen@networkplumber.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-09-26 10:04:23 -07:00
Nikolay Aleksandrov ae75767ec2 net: bridge: add bitfield for options and convert vlan opts
Bridge options have usually been added as separate fields all over the
net_bridge struct taking up space and ending up in different cache lines.
Let's move them to a single bitfield to save up space and speedup lookups.
This patch adds a simple API for option modifying and retrieving using
bitops and converts the first user of the API - the bridge vlan options
(vlan_enabled and vlan_stats_enabled).

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Stephen Hemminger <stephen@networkplumber.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-09-26 10:04:22 -07:00
Andy Shevchenko 459479da97 bridge: Switch to bitmap_zalloc()
Switch to bitmap_zalloc() to show clearly what we are allocating.
Besides that it returns pointer of bitmap type instead of opaque void *.

Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-08-31 23:13:04 -07:00
Petr Machata 9c86ce2c1a net: bridge: Notify about bridge VLANs
A driver might need to react to changes in settings of brentry VLANs.
Therefore send switchdev port notifications for these as well. Reuse
SWITCHDEV_OBJ_ID_PORT_VLAN for this purpose. Listeners should use
netif_is_bridge_master() on orig_dev to determine whether the
notification is about a bridge port or a bridge.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-31 14:13:44 -04:00
Petr Machata dbd6dc752c net: bridge: Extract br_vlan_add_existing()
Extract the code that deals with adding a preexisting VLAN to bridge CPU
port to a separate function. A follow-up patch introduces a need to roll
back operations in this block due to an error, and this split will make
the error-handling code clearer.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-31 14:13:43 -04:00
Petr Machata d66e434896 net: bridge: Extract boilerplate around switchdev_port_obj_*()
A call to switchdev_port_obj_add() or switchdev_port_obj_del() involves
initializing a struct switchdev_obj_port_vlan, a piece of code that
repeats on each call site almost verbatim. While in the current codebase
there is just one duplicated add call, the follow-up patches add more of
both add and del calls.

Thus to remove the duplication, extract the repetition into named
functions and reuse.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Reviewed-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-31 14:13:42 -04:00
Petr Machata 2b18d79e73 net: bridge: Allow bridge master in br_vlan_get_info()
Mirroring offload in mlxsw needs to check that a given VLAN is allowed
to ingress the bridge device. br_vlan_get_info() is the function that is
used for this, however currently it only supports bridge port devices.
Extend it to support bridge masters as well.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-05-10 17:50:51 -04:00
Petr Machata 4d4fd36126 net: bridge: Publish bridge accessor functions
Add a couple new functions to allow querying FDB and vlan settings of a
bridge.

Signed-off-by: Petr Machata <petrm@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-04-30 12:42:40 -04:00
Ido Schimmel 0e5a82efda bridge: Fix VLAN reference count problem
When a VLAN is added on a port, a reference is taken on the
corresponding master VLAN entry. If it does not already exist, then it
is created and a reference taken.

However, in the second case a reference is not really taken when
CONFIG_REFCOUNT_FULL is enabled as refcount_inc() is replaced by
refcount_inc_not_zero().

Fix this by using refcount_set() on a newly created master VLAN entry.

Fixes: 2512775985 ("net, bridge: convert net_bridge_vlan.refcnt from atomic_t to refcount_t")
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-02-26 15:15:53 -05:00
Nikolay Aleksandrov f418af6343 bridge: vlan: signal if anything changed on vlan add
Before this patch there was no way to tell if the vlan add operation
actually changed anything, thus we would always generate a notification
on adds. Let's make the notifications more precise and generate them
only if anything changed, so use the new bool parameter to signal that the
vlan was updated. We cannot return an error because there are valid use
cases that will be broken (e.g. overlapping range add) and also we can't
risk masking errors due to calls into drivers for vlan add which can
potentially return anything.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Toshiaki Makita <makita.toshiaki@lab.ntt.co.jp>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-10-29 11:03:43 +09:00
Reshetova, Elena 2512775985 net, bridge: convert net_bridge_vlan.refcnt from atomic_t to refcount_t
refcount_t type and corresponding API should be
used instead of atomic_t when the variable is used as
a reference counter. This allows to avoid accidental
refcounter overflows that might lead to use-after-free
situations.

Signed-off-by: Elena Reshetova <elena.reshetova@intel.com>
Signed-off-by: Hans Liljestrand <ishkamiel@gmail.com>
Signed-off-by: Kees Cook <keescook@chromium.org>
Signed-off-by: David Windsor <dwindsor@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-07-04 22:35:16 +01:00
Ido Schimmel 1f51445af3 bridge: Export VLAN filtering state
It's useful for drivers supporting bridge offload to be able to query
the bridge's VLAN filtering state.

Currently, upon enslavement to a bridge master, the offloading driver
will only learn about the bridge's VLAN filtering state after the bridge
device was already linked with its slave.

Being able to query the bridge's VLAN filtering state allows such
drivers to forbid enslavement in case resource couldn't be allocated for
a VLAN-aware bridge and also choose the correct initialization routine
for the enslaved port, which is dependent on the bridge type.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-05-26 15:18:44 -04:00
Yotam Gigi df2c43343b bridge: Fix error path in nbp_vlan_init
Fix error path order in nbp_vlan_init, so if switchdev_port_attr_set
call failes, the vlan_hash wouldn't be destroyed before inited.

Fixes: efa5356b0d ("bridge: per vlan dst_metadata netlink support")
CC: Roopa Prabhu <roopa@cumulusnetworks.com>
Signed-off-by: Yotam Gigi <yotamg@mellanox.com>
Acked-by: Roopa Prabhu <roopa@cumulusnetworks.com>
Reviewed-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-03-01 14:55:28 -08:00
Roopa Prabhu 11538d039a bridge: vlan dst_metadata hooks in ingress and egress paths
- ingress hook:
    - if port is a tunnel port, use tunnel info in
      attached dst_metadata to map it to a local vlan
- egress hook:
    - if port is a tunnel port, use tunnel info attached to
      vlan to set dst_metadata on the skb

CC: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Roopa Prabhu <roopa@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-02-03 15:21:22 -05:00
Roopa Prabhu efa5356b0d bridge: per vlan dst_metadata netlink support
This patch adds support to attach per vlan tunnel info dst
metadata. This enables bridge driver to map vlan to tunnel_info
at ingress and egress. It uses the kernel dst_metadata infrastructure.

The initial use case is vlan to vni bridging, but the api is generic
to extend to any tunnel_info in the future:
    - Uapi to configure/unconfigure/dump per vlan tunnel data
    - netlink functions to configure vlan and tunnel_info mapping
    - Introduces bridge port flag BR_LWT_VLAN to enable attach/detach
    dst_metadata to bridged packets on ports. off by default.
    - changes to existing code is mainly refactor some existing vlan
    handling netlink code + hooks for new vlan tunnel code
    - I have kept the vlan tunnel code isolated in separate files.
    - most of the netlink vlan tunnel code is handling of vlan-tunid
    ranges (follows the vlan range handling code). To conserve space
    vlan-tunid by default are always dumped in ranges if applicable.

Use case:
example use for this is a vxlan bridging gateway or vtep
which maps vlans to vn-segments (or vnis).

iproute2 example (patched and pruned iproute2 output to just show
relevant fdb entries):
example shows same host mac learnt on two vni's and
vlan 100 maps to vni 1000, vlan 101 maps to vni 1001

before (netdev per vni):
$bridge fdb show | grep "00:02:00:00:00:03"
00:02:00:00:00:03 dev vxlan1001 vlan 101 master bridge
00:02:00:00:00:03 dev vxlan1001 dst 12.0.0.8 self
00:02:00:00:00:03 dev vxlan1000 vlan 100 master bridge
00:02:00:00:00:03 dev vxlan1000 dst 12.0.0.8 self

after this patch with collect metdata in bridged mode (single netdev):
$bridge fdb show | grep "00:02:00:00:00:03"
00:02:00:00:00:03 dev vxlan0 vlan 101 master bridge
00:02:00:00:00:03 dev vxlan0 src_vni 1001 dst 12.0.0.8 self
00:02:00:00:00:03 dev vxlan0 vlan 100 master bridge
00:02:00:00:00:03 dev vxlan0 src_vni 1000 dst 12.0.0.8 self

CC: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: Roopa Prabhu <roopa@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2017-02-03 15:21:22 -05:00
Nikolay Aleksandrov a60c090361 bridge: netlink: export per-vlan stats
Add a new LINK_XSTATS_TYPE_BRIDGE attribute and implement the
RTM_GETSTATS callbacks for IFLA_STATS_LINK_XSTATS (fill_linkxstats and
get_linkxstats_size) in order to export the per-vlan stats.
The paddings were added because soon these fields will be needed for
per-port per-vlan stats (or something else if someone beats me to it) so
avoiding at least a few more netlink attributes.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-02 22:27:06 -04:00
Nikolay Aleksandrov 6dada9b10a bridge: vlan: learn to count
Add support for per-VLAN Tx/Rx statistics. Every global vlan context gets
allocated a per-cpu stats which is then set in each per-port vlan context
for quick access. The br_allowed_ingress() common function is used to
account for Rx packets and the br_handle_vlan() common function is used
to account for Tx packets. Stats accounting is performed only if the
bridge-wide vlan_stats_enabled option is set either via sysfs or netlink.
A struct hole between vlan_enabled and vlan_proto is used for the new
option so it is in the same cache line. Currently it is binary (on/off)
but it is intentionally restricted to exactly 0 and 1 since other values
will be used in the future for different purposes (e.g. per-port stats).

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-05-02 22:27:06 -04:00
Xin Long 047831a9b9 bridge: a netlink notification should be sent when those attributes are changed by br_sysfs_br
Now when we change the attributes of bridge or br_port by netlink,
a relevant netlink notification will be sent, but if we change them
by ioctl or sysfs, no notification will be sent.

We should ensure that whenever those attributes change internally or from
sysfs/ioctl, that a netlink notification is sent out to listeners.

Also, NetworkManager will use this in the future to listen for out-of-band
bridge master attribute updates and incorporate them into the runtime
configuration.

This patch is used for br_sysfs_br. and we also need to remove some
rtnl_trylock in old functions so that we can call it in a common one.

For group_addr_store, we cannot make it use store_bridge_parm, because
it's not a string-to-long convert, we will add notification on it
individually.

Signed-off-by: Xin Long <lucien.xin@gmail.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-04-13 22:42:33 -04:00
Ido Schimmel 7fbac984f3 bridge: switchdev: Offload VLAN flags to hardware bridge
When VLANs are created / destroyed on a VLAN filtering bridge (MASTER
flag set), the configuration is passed down to the hardware. However,
when only the flags (e.g. PVID) are toggled, the configuration is done
in the software bridge alone.

While it is possible to pass these flags to hardware when invoked with
the SELF flag set, this creates inconsistency with regards to the way
the VLANs are initially configured.

Pass the flags down to the hardware even when the VLAN already exists
and only the flags are toggled.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-02-18 11:18:11 -05:00
Elad Raz 404cdbf089 bridge: add vlan filtering change for new bridged device
Notifying hardware about newly bridged port vlan-aware changes.

Signed-off-by: Elad Raz <eladr@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-01-06 14:42:41 -05:00
Elad Raz 6b72a77020 bridge: add vlan filtering change notification
Notifying hardware about bridge vlan-aware changes.

Signed-off-by: Elad Raz <eladr@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2016-01-06 14:42:40 -05:00
Ido Schimmel 6ff64f6f92 switchdev: Pass original device to port netdev driver
switchdev drivers need to know the netdev on which the switchdev op was
invoked. For example, the STP state of a VLAN interface configured on top
of a port can change while being member in a bridge. In this case, the
underlying driver should only change the STP state of that particular
VLAN and not of all the VLANs configured on the port.

However, current switchdev infrastructure only passes the port netdev down
to the driver. Solve that by passing the original device down to the
driver as part of the required switchdev object / attribute.

This doesn't entail any change in current switchdev drivers. It simply
enables those supporting stacked devices to know the originating device
and act accordingly.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-12-15 11:58:20 -05:00
Ido Schimmel eca1e006cf bridge: vlan: Use rcu_dereference instead of rtnl_dereference
br_should_learn() is protected by RCU and not by RTNL, so use correct
flavor of nbp_vlan_group().

Fixes: 907b1e6e83 ("bridge: vlan: use proper rcu for the vlgrp
member")
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Acked-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-11-02 16:27:39 -05:00
Ido Schimmel ddd611d3ff bridge: vlan: Use correct flag name in comment
The flag used to indicate if a VLAN should be used for filtering - as
opposed to context only - on the bridge itself (e.g. br0) is called
'brentry' and not 'brvlan'.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Acked-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-11-02 15:40:11 -05:00
Ido Schimmel 07bc588fc1 bridge: vlan: Prevent possible use-after-free
When adding a port to a bridge we initialize VLAN filtering on it. We do
not bail out in case an error occurred in nbp_vlan_init, as it can be
used as a non VLAN filtering bridge.

However, if VLAN filtering is required and an error occurred in
nbp_vlan_init, we should set vlgrp to NULL, so that VLAN filtering
functions (e.g. br_vlan_find, br_get_pvid) will know the struct is
invalid and will not try to access it.

Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-11-02 15:40:10 -05:00
Nikolay Aleksandrov f409d0ed87 bridge: vlan: move back vlan_flush
Ido Schimmel reported a problem with switchdev devices because of the
order change of del_nbp operations, more specifically the move of
nbp_vlan_flush() which deletes all vlans and frees vlgrp after the
rx_handler has been unregistered. So in order to fix this move
vlan_flush back where it was and make it destroy the rhtable after
NULLing vlgrp and waiting a grace period to make sure noone can see it.

Reported-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-13 04:57:58 -07:00
Nikolay Aleksandrov b8d02c3cac bridge: vlan: drop unnecessary flush code
As Ido Schimmel pointed out the vlan_vid_del() code in nbp_vlan_flush is
unnecessary (and is actually a remnant of the old vlan code) so we can
remove it.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-13 04:57:56 -07:00
Nikolay Aleksandrov 907b1e6e83 bridge: vlan: use proper rcu for the vlgrp member
The bridge and port's vlgrp member is already used in RCU way, currently
we rely on the fact that it cannot disappear while the port exists but
that is error-prone and we might miss places with improper locking
(either RCU or RTNL must be held to walk the vlan_list). So make it
official and use RCU for vlgrp to catch offenders. Introduce proper vlgrp
accessors and use them consistently throughout the code.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Reviewed-by: Ido Schimmel <idosch@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-13 04:57:52 -07:00
Jiri Pirko 0944d6b5a2 bridge: try switchdev op first in __vlan_vid_add/del
Some drivers need to implement both switchdev vlan ops and
vid_add/kill ndos. For that to work in bridge code, we need to try
switchdev op first when adding/deleting vlan id.

Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Signed-off-by: Ido Schimmel <idosch@mellanox.com>
Acked-by: Scott Feldman <sfeldma@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-12 19:35:20 -07:00
Roopa Prabhu 3741873b4f bridge: allow adding of fdb entries pointing to the bridge device
This patch enables adding of fdb entries pointing to the bridge device.
This can be used to propagate mac address of vlan interfaces
configured on top of the vlan filtering bridge.

Before:
$bridge fdb add 44:38:39:00:27:9f dev bridge
RTNETLINK answers: Invalid argument

After:
$bridge fdb add 44:38:39:00:27:9f dev bridge

Signed-off-by: Roopa Prabhu <roopa@cumulusnetworks.com>
Reviewed-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-12 05:11:58 -07:00
Nikolay Aleksandrov 0f963b7592 bridge: netlink: add support for default_pvid
Add IFLA_BR_VLAN_DEFAULT_PVID to allow setting/getting bridge's
default_pvid via netlink.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-04 16:46:07 -07:00
Nikolay Aleksandrov 6be144f62f bridge: vlan: use br_vlan_should_use to simplify __vlan_add/del
The checks that lead to num_vlans change are always what
br_vlan_should_use checks for, namely if the vlan is only a context or
not and depending on that it's either not counted or counted
as a real/used vlan respectively.
Also give better explanation in br_vlan_should_use's comment.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-04 16:43:50 -07:00
Nikolay Aleksandrov 2ffdf508d2 bridge: vlan: drop master_flags from __vlan_add
There's only one user now and we can include the flag directly.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-04 16:43:49 -07:00
Nikolay Aleksandrov f8ed289fab bridge: vlan: use br_vlan_(get|put)_master to deal with refcounts
Introduce br_vlan_(get|put)_master which take a reference (or create the
master vlan first if it didn't exist) and drop a reference respectively.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-04 16:43:48 -07:00
Nikolay Aleksandrov 586c2b573e bridge: vlan: use rcu list for the ordered vlan list
When I did the conversion to rhashtable I missed the required locking of
one important user of the vlan list - br_get_link_af_size_filtered()
which is called:
br_ifinfo_notify() -> br_nlmsg_size() -> br_get_link_af_size_filtered()
and the notifications can be sent without holding rtnl. Before this
conversion the function relied on using rcu and since we already use rcu to
destroy the vlans, we can simply migrate the list to use the rcu helpers.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-04 16:43:47 -07:00
Jiri Pirko 9e8f4a548a switchdev: push object ID back to object structure
Suggested-by: Scott Feldman <sfeldma@gmail.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Acked-by: Scott Feldman <sfeldma@gmail.com>
Reviewed-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-03 04:49:40 -07:00
Jiri Pirko 648b4a995a switchdev: bring back switchdev_obj and use it as a generic object param
Replace "void *obj" with a generic structure. Introduce couple of
helpers along that.

Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Acked-by: Scott Feldman <sfeldma@gmail.com>
Reviewed-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-03 04:49:39 -07:00
Jiri Pirko 8f24f3095d switchdev: rename switchdev_obj_vlan to switchdev_obj_port_vlan
Make the struct name in sync with object id name.

Suggested-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Acked-by: Scott Feldman <sfeldma@gmail.com>
Reviewed-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-03 04:49:38 -07:00
Jiri Pirko 57d80838da switchdev: rename SWITCHDEV_OBJ_* enum values to SWITCHDEV_OBJ_ID_*
Suggested-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: Jiri Pirko <jiri@mellanox.com>
Acked-by: Scott Feldman <sfeldma@gmail.com>
Reviewed-by: Vivien Didelot <vivien.didelot@savoirfairelinux.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-03 04:49:36 -07:00
Nikolay Aleksandrov 248234ca02 bridge: vlan: don't pass flags when creating context only
We should not pass the original flags when creating a context vlan only
because they may contain some flags that change behaviour in the bridge.
The new global context should be with minimal set of flags, so pass 0
and let br_vlan_add() set the master flag only.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-01 18:24:05 -07:00
Nikolay Aleksandrov 263344e64c bridge: vlan: fix possible null ptr derefs on port init and deinit
When a new port is being added we need to make vlgrp available after
rhashtable has been initialized and when removing a port we need to
flush the vlans and free the resources after we're sure noone can use
the port, i.e. after it's removed from the port list and synchronize_rcu
is executed.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-01 18:24:05 -07:00
Nikolay Aleksandrov 77751ee8ae bridge: vlan: move pvid inside net_bridge_vlan_group
One obvious way to converge more code (which was also used by the
previous vlan code) is to move pvid inside net_bridge_vlan_group. This
allows us to simplify some and remove other port-specific functions.
Also gives us the ability to simply pass the vlan group and use all of the
contained information.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-01 18:24:04 -07:00
Nikolay Aleksandrov 468e794458 bridge: vlan: fix possible null vlgrp deref while registering new port
While a new port is being initialized the rx_handler gets set, but the
vlans get initialized later in br_add_if() and in that window if we
receive a frame with a link-local address we can try to dereference
p->vlgrp in:
br_handle_frame() -> br_handle_local_finish() -> br_should_learn()

Fix this by checking vlgrp before using it.

Signed-off-by: Nikolay Aleksandrov <nikolay@cumulusnetworks.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2015-10-01 18:24:04 -07:00