Javi Merino ea54cac906 thermal: power_allocator: round the division when divvying up power
In situations where there is an uneven number of cooling devices, the
division of power among them can lead to a milliwatt being dropped on
the floor due to rounding errors.  This doesn't sound like a lot, but
some devices only grant the lowest cooling device state for their
maximum power.  So for instance, if the granted_power is the maximum
power and all devices are getting their maximum power, one would get
max_power - 1, making it choose cooling device state 1, instead of 0.

Round the division to make the calculation more accurate.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-05-11 18:57:44 -07:00
Javi Merino 6828a4711f thermal: add trace events to the power allocator governor
Add trace events for the power allocator governor and the power actor
interface of the cpu cooling device.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Frederic Weisbecker <fweisbec@gmail.com>
Cc: Ingo Molnar <mingo@redhat.com>
Acked-by: Steven Rostedt <rostedt@goodmis.org>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-05-04 21:27:52 -07:00
Javi Merino 6b775e870c thermal: introduce the Power Allocator governor
The power allocator governor is a thermal governor that controls system
and device power allocation to control temperature.  Conceptually, the
implementation divides the sustainable power of a thermal zone among
all the heat sources in that zone.

This governor relies on "power actors", entities that represent heat
sources.  They can report current and maximum power consumption and
can set a given maximum power consumption, usually via a cooling
device.

The governor uses a Proportional Integral Derivative (PID) controller
driven by the temperature of the thermal zone.  The output of the
controller is a power budget that is then allocated to each power
actor that can have bearing on the temperature we are trying to
control.  It decides how much power to give each cooling device based
on the performance they are requesting.  The PID controller ensures
that the total power budget does not exceed the control temperature.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2015-05-04 21:27:52 -07:00