Traditional SLI4 required the driver to clear Valid bits on
EQEs and CQEs after consuming them.
The new if_type=6 hardware will cycle the value for what is
valid on each queue itteration. The driver no longer has to
touch the valid bits. This also means all the cpu cache
dirtying and perhaps flush/refill's done by the hardware
in accessing the EQ/CQ elements is eliminated.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
New if_type=6 adapters support an additional BAR that provides
apertures to allow direct WQE to adapter push support - termed
Direct Packet Push (DPP). WQ creation differs slightly to ask for
a WQ to be DPP-ized. When submitting a WQE to a DPP WQ, it is
submitted to the host memory for the WQ normally, but is also
written by the host cpu directly to a BAR aperture. Write buffer
coalescing in hardware is (hopefully) turned on, enabling single
pci write operation support. The doorbell is thing rung to indicate
the WQE is available and was pushed to the aperture.
This patch:
- Updates the WQ Create commands for the DPP options
- Adds the bar mapping for if_type=6 DPP bar
- Adds the WQE pushing to the DDP aperture received from WQ create
- Adds a new module parameter to disable DPP operation if desired.
Default is enabled.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
New hardware supports a SLI-4 interface, but with a new if_type
variant of 6.
If_type=6 has a different PCI BAR map, separate EQ/CQ doorbells,
and some changes in doorbell formats.
Add the changes for the if_type into headers, adapter initialization
and control flows. Add new eq and cq handlers.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Up until now, all SLI-4 devices had the same doorbells at the same
bar locations. With newer hardware, there are now independent EQ and
CQ doorbells and the bar locations differ.
Prepare the code for new hardware by separating the eq/cq doorbell into
separate components. The components can be set based on if_type.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Up until now, an SLI-4 device had no variance in the way it handled
its EQs and CQs. With newer hardware, there are now differences in
doorbells and some differences in how entries are valid.
Prepare the code for new hardware by creating a sli4-based callout
table that can be set based on if_type.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Updated Copyright in files updated 11.4.0.7
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
I/O conditions on the nvme target may have the driver submitting to a
full hardware wq. The hardware wq is a shared resource among all nvme
controllers. When the driver hit a full wq, it failed the io posting
back to the nvme-fc transport, which then escalated it into errors.
Correct by maintaining a sideband queue within the driver that is added
to when the WQ full condition is hit, and drained from as soon as new WQ
space opens up.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Increased CQ and WQ sizes for SCSI FCP, matching those used for NVMe
development.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Increased the sizes of the SCSI WQ's and CQ's so that SCSI operation is
similar to that used by NVME. However, size increase restricted only to
those newer adapters that can support the larger WQE size, thus bigger
queue sizes.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
XRI_ABORTED_CQE completions were not being handled in the fast path.
They were being queued and deferred to the lpfc worker thread for
processing. This is an artifact of the driver design prior to moving
queue processing out of the isr and into a workq element. Now that queue
processing is already in a deferred context, remove this artifact and
process them directly.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Hardware queues are a fast staging area to push commands into the
adapter. The adapter should drain them extremely quickly. However,
under heavy io load, the host cpu is pushing commands faster than the
drain rate of the adapter causing the driver to resource busy commands.
Enlarge the hardware queue (wq & cq) to support a larger number of queue
entries (4x the prior size) before backpressure. Enlarging the queue
requires larger contiguous buffers (16k) per logical page for the
hardware. This changed calling sequences that were expecting 4K page
sizes that now must pass a parameter with the page sizes. It also
required use of a new version of an adapter command that can vary the
page size values.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Under heavy target nvme load duration, the lpfc irq handler is
encountering cpu lockup warnings.
Convert the driver to a shortened ISR handler which identifies the
interrupting condition then schedules a workq thread to process the
completion queue the interrupt was for. This moves all the real work
into the workq element.
As nvmet_fc upcalls are no longer in ISR context, don't set the feature
flags
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Add Buffer to buffer credit recovery support to the driver. This is a
negotiated feature with the peer that allows for both sides to detect
dropped RRDY's and FC Frames and recover credit.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Various oops including cpu LOCKUPs were seen.
For asynchronously received ius where the driver must assign exchange
resources, the resources were on a single get (free) list and put list
(finished, waiting to be put on get list). As all cpus are sharing the
lists, an interrupt for a receive frame may have to wait for all the
other cpus to place their done work onto the put list before it can
acquire the lock to pull from the list.
Fix by breaking the resource lists into per-cpu lists or at least more
than 1 list with cpu's sharing the lists). A cpu would allocate from the
free list for its own cpu, and put its done work on the its own put list
- avoiding the contention. As cpu load may vary, when empty, a cpu may
grab from another cpu, thereby changing resource distribution. But
searching for a resource only occurs on 1 or a few cpus until a single
resource can be allocated. if the condition reoccurs, it starts looking
at a different cpu.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Various oops being seen on being in the ISR too long and cpu lockups,
when under heavy load.
The amount of work being posted off of completion queues kept the ISR
running almost all the time
Correct the issue by limiting the amount of work per iteration.
[mkp: typo]
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Since unsol rcv ISR and command cmpl ISR both access/lock this list,
separate get/put lists will reduce contention.
Replaced
struct list_head lpfc_nvmet_ctx_list;
with
struct list_head lpfc_nvmet_ctx_get_list;
struct list_head lpfc_nvmet_ctx_put_list;
and all correpsonding locks and counters.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Administrator intervention is currently required to get good numbers
when switching from running latency tests to IOPS tests.
The configured interrupt coalescing values will greatly effect the
results of these tests. Currently, the driver has a single coalescing
value set by values of the module attribute. This patch changes the
driver to support auto-configuration of the coalescing value based on
the total number of outstanding IOs and average number of CQEs processed
per interrupt for an EQ. Values are checked every 5 seconds.
The driver defaults to the automatic selection. Automatic selection can
be disabled by the new lpfc_auto_imax module_parameter.
Older hardware can only change interrupt coalescing by mailbox
command. Newer hardware supports change via a register. The patch
support both.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
System panic with general protection fault during driver load
The driver uses a static array sli4_hba.handler_name to store the irq
handler names. If the io_channel_irqs exceeds the pre-allocated size
(32+1), then the driver will overwrite other fields of sli4_hba.
Fix: Dynamically allocate handler_name.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Too many work items being processed in IRQ context take a lot of CPU
time and cause problems.
With a recent change, we get out of the ISR after hitting entry_repost
work items on a queue. However, the actual values for entry repost are
still high. EQ is 128 and CQ is 128, this could translate into
processing 128 * 128 (16384) work items under IRQ context.
Set entry_repost in the actual queue creation routine now. Limit EQ
repost to 8 and CQ repost to 64 to further limit the amount of time
spent in the IRQ.
Fix fof IRQ routines as well.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Previous logic would just drop the IO.
Added logic to queue the IO to wait for an IO context resource from an
IO thats already in progress.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Currently IO resources are mapped 1 to 1 with RQ buffers posted
Added logic to separate RQE buffers from IO op resources
(sgl/iocbq/context). During initialization, the driver will determine
how many SGLs it will allocate for NVMET (based on what the firmware
reports) and associate a NVMET IOCBq and NVMET context structure with
each one.
Now that hdr/data buffers are immediately reposted back to the RQ, 512
RQEs for each MRQ is sufficient. Also, since NVMET data buffers are now
128 bytes, lpfc_nvmet_mrq_post is not necessary anymore as we will
always post the max (512) buffers per NVMET MRQ.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Large block writes to the nvme target were failing because the default
number of RQs posted was insufficient.
Expand the NVMET RQs to 2048 RQEs and ensure a minimum of 512 RQEs are
posted, no matter how many MRQs are configured.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
More debug messages added for nvme statistics.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
With 255 vports created a link trasition can casue a crash.
When going through discovery after a link bounce the driver is using
rpis before the cmd FCOE_POST_HDR_TEMPLATES completes. By doing that the
next rpi bumps the rpi range out of the boundary.
The fix it to increment the next_rpi only when the
FCOE_POST_HDR_TEMPLATE succeeds.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
The driver with nvme had this routine stubbed.
Right now XRI_ABORTED_CQE is not handled and the FC NVMET
Transport has a new API for the driver.
Missing code path, new NVME abort API
Update ABORT processing for NVMET
There are 3 new FC NVMET Transport API/ template routines for NVMET:
lpfc_nvmet_xmt_fcp_release
This NVMET template callback routine called to release context
associated with an IO This routine is ALWAYS called last, even
if the IO was aborted or completed in error.
lpfc_nvmet_xmt_fcp_abort
This NVMET template callback routine called to abort an exchange that
has an IO in progress
nvmet_fc_rcv_fcp_req
When the lpfc driver receives an ABTS, this NVME FC transport layer
callback routine is called. For this case there are 2 paths thru the
driver: the driver either has an outstanding exchange / context for the
XRI to be aborted or not. If not, a BA_RJT is issued otherwise a BA_ACC
NVMET Driver abort paths:
There are 2 paths for aborting an IO. The first one is we receive an IO and
decide not to process it because of lack of resources. An unsolicated ABTS
is immediately sent back to the initiator as a response.
lpfc_nvmet_unsol_fcp_buffer
lpfc_nvmet_unsol_issue_abort (XMIT_SEQUENCE_WQE)
The second one is we sent the IO up to the NVMET transport layer to
process, and for some reason the NVME Transport layer decided to abort the
IO before it completes all its phases. For this case there are 2 paths
thru the driver:
the driver either has an outstanding TSEND/TRECEIVE/TRSP WQE or no
outstanding WQEs are present for the exchange / context.
lpfc_nvmet_xmt_fcp_abort
if (LPFC_NVMET_IO_INP)
lpfc_nvmet_sol_fcp_issue_abort (ABORT_WQE)
lpfc_nvmet_sol_fcp_abort_cmp
else
lpfc_nvmet_unsol_fcp_issue_abort
lpfc_nvmet_unsol_issue_abort (XMIT_SEQUENCE_WQE)
lpfc_nvmet_unsol_fcp_abort_cmp
Context flags:
LPFC_NVMET_IOP - his flag signifies an IO is in progress on the exchange.
LPFC_NVMET_XBUSY - this flag indicates the IO completed but the firmware
is still busy with the corresponding exchange. The exchange should not be
reused until after a XRI_ABORTED_CQE is received for that exchange.
LPFC_NVMET_ABORT_OP - this flag signifies an ABORT_WQE was issued on the
exchange.
LPFC_NVMET_CTX_RLS - this flag signifies a context free was requested,
but we are deferring it due to an XBUSY or ABORT in progress.
A ctxlock is added to the context structure that is used whenever these
flags are set/read within the context of an IO.
The LPFC_NVMET_CTX_RLS flag is only set in the defer_relase routine when
the transport has resolved all IO associated with the buffer. The flag is
cleared when the CTX is associated with a new IO.
An exchange can has both an LPFC_NVMET_XBUSY and a LPFC_NVMET_ABORT_OP
condition active simultaneously. Both conditions must complete before the
exchange is freed.
When the abort callback (lpfc_nvmet_xmt_fcp_abort) is envoked:
If there is an outstanding IO, the driver will issue an ABORT_WQE. This
should result in 3 completions for the exchange:
1) IO cmpl with XB bit set
2) Abort WQE cmpl
3) XRI_ABORTED_CQE cmpl
For this scenerio, after completion #1, the NVMET Transport IO rsp
callback is called. After completion #2, no action is taken with respect
to the exchange / context. After completion #3, the exchange context is
free for re-use on another IO.
If there is no outstanding activity on the exchange, the driver will send a
ABTS to the Initiator. Upon completion of this WQE, the exchange / context
is freed for re-use on another IO.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
previous code did little more than log a message.
This patch adds abort path support, modeled after the SCSI code paths.
Currently addresses only the initiator path. Target path under
development, but stubbed out.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Update copyrights to 2017 for all files touched in this patch set
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
NVME Target: Receive buffer updates
Allocates buffer pools and configures adapter interfaces to handle
receive buffer (asynchronous FCP CMD ius, first burst data)
from the adapter. Splits by protocol, etc.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
NVME Target: Base modifications
This set of patches adds the base modifications for NVME target support
The base modifications consist of:
- Additional module parameters or configuration tuning
- Enablement of configuration mode for NVME target. Ties into the
queueing model put into place by the initiator basemods patches.
- Target-specific buffer pools, dma pools, sgl pools
[mkp: fixed space at end of file]
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
NVME Initiator: Tie in to NVME Fabrics nvme_fc LLDD initiator api
Adds the routines to:
- register and deregister the FC port as a nvme-fc initiator localport
- register and deregister remote FC ports as a nvme-fc remoteport
- binding of nvme queues to adapter WQs
- send/perform NVME LS's
- send/perform NVME FCP initiator io operations
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
NVME Initiator: Base modifications
This patch adds base modifications for NVME initiator support.
The base modifications consist of:
- Formal split of SLI3 rings from SLI-4 WQs (sometimes referred to as
rings as well) as implementation now widely varies between the two.
- Addition of configuration modes:
SCSI initiator only; NVME initiator only; NVME target only; and
SCSI and NVME initiator.
The configuration mode drives overall adapter configuration,
offloads enabled, and resource splits.
NVME support is only available on SLI-4 devices and newer fw.
- Implements the following based on configuration mode:
- Exchange resources are split by protocol; Obviously, if only
1 mode, then no split occurs. Default is 50/50. module attribute
allows tuning.
- Pools and config parameters are separated per-protocol
- Each protocol has it's own set of queues, but share interrupt
vectors.
SCSI:
SLI3 devices have few queues and the original style of queue
allocation remains.
SLI4 devices piggy back on an "io-channel" concept that
eventually needs to merge with scsi-mq/blk-mq support (it is
underway). For now, the paradigm continues as it existed
prior. io channel allocates N msix and N WQs (N=4 default)
and either round robins or uses cpu # modulo N for scheduling.
A bunch of module parameters allow the configuration to be
tuned.
NVME (initiator):
Allocates an msix per cpu (or whatever pci_alloc_irq_vectors
gets)
Allocates a WQ per cpu, and maps the WQs to msix on a WQ #
modulo msix vector count basis.
Module parameters exist to cap/control the config if desired.
- Each protocol has its own buffer and dma pools.
I apologize for the size of the patch.
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
----
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This avoids having to store the msix_entries array and simpliefies the
shutdown and cleanup path a lot.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Copyright updates
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Add recovery from adapter parity errors on some SLI4 adapters
Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Add logging for misconfigured optics acqe reported by fw.
Signed-off-by: Dick Kennedy <dick.kennedy@avagotech.com>
Signed-off-by: James Smart <james.smart@avagotech.com>
Reviewed-by: Hannes Reinicke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Dick Kennedy <dick.kennedy@avagotech.com>
Signed-off-by: James Smart <james.smart@avagotech.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Also has a little whitespace fixing.
Signed-off-by: Dick Kennedy <dick.kennedy@avagotech.com>
Signed-off-by: James Smart <james.smart@avagotech.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Update copyright to 2015
Signed-off-by: Dick Kennedy <dick.kennedy@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Signed-off-by: Dick Kennedy <dick.kennedy@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Fixed High priority issues from lpfc given by fortify source code scan.
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: Dick Kennedy <dick.kennedy@emulex.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Update Copyright on changed files from 8.3.45 patches
Missed this in the 8.3.45 push
Signed-off-by: James Smart <james.smart@emulex.com>
Reviewed-By: Dick Kennedy <dick.kennedy@emulex.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>