This patch check periodically fully charged state of battery to protect
overcharge and overheat. If battery is fully charged, stop charging and
check droped voltage with 'fullbatt_vchkdrop_ms' period. When voltage of
battery is more droped than 'fullbatt_vchkdrop_uV' voltage,
charger-manager will restart charging for battery.
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
The comment says that charger_regulators is an array of
regulator_bulk_data, which is not true, since it's actually a pointer
to 'struct charger_regulator'.
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This patch remove unnecessary variable(cm->fullbatt_vchk_uV) by using
'desc->fullbatt_uV' field directly in fullbatt_handler() function
to check the state of battery.
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This patch support the protection of host device from over current.
The Charger-manager set proper current limit of charger(regulator) for
charging according to type of charger cable when external connector
is attached.
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This patch support that charger-manager use EXTCON(External Connector)
Subsystem to detect the state of charger cables for enabling or disabling
charger(regulator) and select the charger cable for charging among
a number of external cable according to policy of H/W board.
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
By using cm_notify_event function, charger driver can report several
charger events (e.g. battery full and external power in/out, etc) to
Charger-Manager. Charger-Manager can properly and immediately control
chargers by the reported event.
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Charger-Manager needs to check battery health in normal state
as well as suspend-to-RAM state. When the battery is fully charged,
Charger-Manager needs to determine when the chargers restart charging.
This patch allows Charger-Manager to monitor battery health in normal
state and handle operation for chargers after battery is fully charged.
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Charger Manager provides power-supply-class aggregating
information from multiple chargers and a fuel-gauge.
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Because battery health monitoring should be done even when suspended,
it needs to wake up and suspend periodically. Thus, userspace battery
monitoring may incur too much overhead; every device and task is woken
up periodically. Charger Manager uses suspend-again to provide
in-suspend monitoring.
This patch allows to monitor battery health in-suspend state.
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>