There are two regmap_update_bits() calls but only one of them has
return value check, which is odd. Add a return value check and
terminate the execution flow on failure just like the other call.
Signed-off-by: Dinghao Liu <dinghao.liu@zju.edu.cn>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The kernel test robot reports an unused variable in the
Z2 battery code caused by a recent commit.
Fixes: a3b4388ea1 ("power: supply: z2_battery: Convert to GPIO descriptors")
Reported-by: kernel test robot <lkp@intel.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Improve formatting of the code by removing unnecessary whitespaces.
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
A previous commit attempted to fix IRQ usage in a case where interrupt
is failed to initialize, but it missed couple more cases that could be
improved. The interrupt could be undefined and then everything related
to interrupt shouldn't be touched by driver. Secondly, we shouldn't ignore
errors that aren't directly related to enabling interrupt in hardware,
like enabling h/w write-access or requesting interrupt. Improve interrupt
initialization in the driver in order to handle the missing cases.
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The "pdata" local variable is not used in suspend/resume handlers since
commit 7776bcd241 ("power: supply: s3c-adc-battery: Convert to GPIO
descriptors"):
drivers/power/supply/s3c_adc_battery.c: In function ‘s3c_adc_bat_suspend’:
drivers/power/supply/s3c_adc_battery.c:405:28: warning: unused variable ‘pdata’ [-Wunused-variable]
drivers/power/supply/s3c_adc_battery.c: In function ‘s3c_adc_bat_resume’:
drivers/power/supply/s3c_adc_battery.c:422:28: warning: unused variable ‘pdata’ [-Wunused-variable]
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
CHARGE_NOW is expected by some user software (such as waybar)
instead of 'CAPACITY', in order to correctly calculate remaining battery
life.
Signed-off-by: Martin Ashby <martin@ashbysoft.com>
Reviewed-by: Tobias Schramm <t.schramm@manjaro.org>
Tested-by: Tobias Schramm <t.schramm@manjaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Use kobj_to_dev() instead of open-coding it
Signed-off-by: Jian Dong <dongjian@yulong.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The zte zx platform is getting removed, so this driver is no
longer needed.
Cc: Jun Nie <jun.nie@linaro.org>
Cc: Shawn Guo <shawnguo@kernel.org>
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The i2c_device_id bq25975 is repeated, and should be bq25960.
Signed-off-by: xinjian <xinjian@yulong.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The IRQ=0 could be a valid interrupt number in kernel because interrupt
numbers are virtual in a modern kernel. Hence fix the interrupt usage in
a case if interrupt is unavailable by not overriding the interrupt number
which is used by the driver.
Note that currently Nexus 7 is the only know device which uses SMB347
kernel diver and it has a properly working interrupt, hence this patch
doesn't fix any real problems, it's a minor cleanup/improvement.
Fixes: 99298de5df ("power: supply: smb347-charger: Replace mutex with IRQ disable/enable")
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The IRQ handler calls mod_delayed_work() on power->vbus_detect. However,
that work item is not initialized until after the IRQs are enabled. If
an IRQ is already pending when the driver is probed, the driver calls
mod_delayed_work() on an uninitialized work item, which causes an oops.
Fixes: bcfb7ae3f5 ("power: supply: axp20x_usb_power: Only poll while offline")
Signed-off-by: Samuel Holland <samuel@sholland.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
CHARGER_SBS should select REGMAP_I2C since it uses API(s) that are
provided by that Kconfig symbol.
Fixes these errors:
../drivers/power/supply/sbs-charger.c:149:21: error: variable ‘sbs_regmap’ has initializer but incomplete type
static const struct regmap_config sbs_regmap = {
../drivers/power/supply/sbs-charger.c:150:3: error: ‘const struct regmap_config’ has no member named ‘reg_bits’
.reg_bits = 8,
../drivers/power/supply/sbs-charger.c:155:23: error: ‘REGMAP_ENDIAN_LITTLE’ undeclared here (not in a function)
.val_format_endian = REGMAP_ENDIAN_LITTLE, /* since based on SMBus */
../drivers/power/supply/sbs-charger.c: In function ‘sbs_probe’:
../drivers/power/supply/sbs-charger.c:183:17: error: implicit declaration of function ‘devm_regmap_init_i2c’; did you mean ‘devm_request_irq’? [-Werror=implicit-function-declaration]
chip->regmap = devm_regmap_init_i2c(client, &sbs_regmap);
../drivers/power/supply/sbs-charger.c: At top level:
../drivers/power/supply/sbs-charger.c:149:35: error: storage size of ‘sbs_regmap’ isn’t known
static const struct regmap_config sbs_regmap = {
Fixes: feb583e37f ("power: supply: add sbs-charger driver")
Reported-by: Martin Mokrejs <mmokrejs@fold.natur.cuni.cz>
Signed-off-by: Randy Dunlap <rdunlap@infradead.org>
Tested-by: Martin Mokrejs <mmokrejs@fold.natur.cuni.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
current_now has to be negative during discharging and positive during
charging, the behavior seen is the other way round.
Tested on GTA04 with Openmoko battery.
Signed-off-by: Andreas Kemnade <andreas@kemnade.info>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
cm->emergency_stop will only be the value in the enumeration,
and cannot be less than zero, it will get an exception value.
So replace it with the corresponding value.
Signed-off-by: Junlin Yang <yangjunlin@yulong.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add support for SAMA7G5 by adding proper struct reg_config structure
and since SAMA7G5 is not currently on LPDDR setups the commit also
avoid the mapping of DDR controller.
Signed-off-by: Claudiu Beznea <claudiu.beznea@microchip.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Replace a comma between expression statements by a semicolon.
Signed-off-by: Zheng Yongjun <zhengyongjun3@huawei.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Replace a comma between expression statements by a semicolon.
Signed-off-by: Zheng Yongjun <zhengyongjun3@huawei.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
fixed the following coccicheck:
drivers/power/supply/ds2780_battery.c:627:60-61: WARNING opportunity for
kobj_to_dev()
drivers/power/supply/ds2780_battery.c:672:60-61: WARNING opportunity for
kobj_to_dev()
drivers/power/supply/ds2780_battery.c:640:60-61: WARNING opportunity for
kobj_to_dev()
drivers/power/supply/ds2780_battery.c:685:60-61: WARNING opportunity for
kobj_to_dev()
Signed-off-by: Tian Tao <tiantao6@hisilicon.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Currently REG_NAC (nominal available capacity) is mapped to
power-supply's CHARGE_NOW property. Some chips do not have
REG_NAC and do not expose CHARGE_NOW at the moment. Some
bq27xxx chips also have another register REG_RM (remaining
capacity). The difference between REG_NAC and REG_RM is load
compensation.
This patch adds register information for REG_RM for all
supported fuel gauges. On systems having REG_NAC it is
ignored, so behaviour does not change. On systems without
REG_NAC, REG_RM will be used to provide CHARGE_NOW
functionality.
As a result there are three more chips exposing CHARGE_NOW:
bq27z561, bq28z610 and bq34z100
Signed-off-by: Hermes Zhang <chenhuiz@axis.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Currently if the pointer battery is null there is a null pointer
dereference on the call to power_supply_put. Fix this by only
performing the put if battery is not null.
Addresses-Coverity: ("Dereference after null check")
Fixes: 4bff91bb32 ("power: supply: cpcap-charger: Fix missing power_supply_put()")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
There is no dynamic information in cpcap-battery's
power-supply description struct, so let's make it
static const.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Acked-by: Pavel Machek <pavel@ucw.cz>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Fix typo
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
[tony@atomide.com: separated out from charger changes]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add charge_now property for capacity reporting.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Arthur Demchenkov <spinal.by@gmail.com>
[tony@atomide.com: updated to apply for naming changes]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Calculate percentage using charge_full value provided.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Arthur Demchenkov <spinal.by@gmail.com>
[tony@atomide.com: updated to apply after dropping my earlier patch]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Save the battery empty and full states so we can use those to estimate
the battery capacity in the following patches.
If the user provides us with charge_full value (which it could save in a
permanent storage between reboots), initialize low and high counter_uah
with calculated values.
If we hit battery low once, we should stick on reporting it until the
charger is connected. This way low->counter_uah will be updated
properly, and that will allow us to get more accurate charge_full value.
Based on an earlier patch by Tony Lindgren with charge_full usage and
other improvments done by Arthur Demchenkov.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Co-developed-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Arthur Demchenkov <spinal.by@gmail.com>
[tony@atomide.com: combined earlier patches, updated comments]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add charge_full property and let user update it. This is needed for
capacity reporting in the following patches.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Arthur Demchenkov <spinal.by@gmail.com>
[tony@atomide.com: updated comments]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We now get battery full notification from cpcap-charger, so let's use that
for battery full status and charger disconnect.
Note that any current based battery full detection we have tried earlier is
flakey as it won't account for example for CPU load increasing the battery
current. Anyways, if current based battery full detection is also still
needed, we can reconsider adding it in addition to the charger status based
detection.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We want to have the battery update it's status when the charge is done,
and when the charger is disconnected. Otherwise the battery does not know
when it's full unless there's a userspace app polling the battery status.
To do this, we add supplied_to handling to cpcap-battery, and implement
power_supply_changed() for cpcap-charger. When cpcap-charger calls
power_supply_changed(), cpcap-battery will update it's status.
Let's also use new_state variable for the POWER_SUPPLY_STATUS_CHARGING
case to have unified handling for the switch.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Let's turn cpcap_charger_set_state() into separate cpcap_charger_enable()
and cpcap_charger_disable() to simplify things, and to allow managing
status separately. This can be then used for the follow-up patches to
make battery full status behave a bit nicer.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
We currently have both state and status, get rid of state and use
generic status instead.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Droid 4 has same problem as N900: it is often necessary to manually
tweak current draw from USB, for example when using thin charging cable.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
[tony@atomide.com: rebased, cleaned up whitespace issues, updated comments]
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Just get rid of the custom enumeration if favor of the standard one.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This should be only shown when debug is enabled.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
If we have a USB charger connected, reboot is flakey and often fails to
reboot the device with the charger LED staying on.
Let's fix this by implementing .shutdown.
Cc: Arthur Demchenkov <spinal.by@gmail.com>
Cc: Carl Philipp Klemm <philipp@uvos.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This patch adds battery gauge driver for Acer Iconia Tab A500 device.
The battery gauge function is provided via the Embedded Controller,
which is found on the Acer A500.
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Corrects BQ256XX_NUM_WD_VAL from value of "8" to "4" and fixes the issue when 'i'
is equal to array size then array index over runs the array
Fixes: 32e4978bb9 ("power: supply: bq256xx: Introduce the BQ256XX charger driver")
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Ricardo Rivera-Matos <r-rivera-matos@ti.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This immutable branch replaces legacy gpio API in wm97xx_battery and
z2_battery with new gpiod API, which involves the drivers in
power-supply and some mach-pxa board files.
Signed-off-by: Sebastian Reichel <sre@kernel.org>
-----BEGIN PGP SIGNATURE-----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=c7Ln
-----END PGP SIGNATURE-----
Merge tag 'ib-psy-pxa-for-5.12-signed' into psy-next
Immutable branch between mach-pxa and power-supply for for 5.12
This immutable branch replaces legacy gpio API in wm97xx_battery and
z2_battery with new gpiod API, which involves the drivers in
power-supply and some mach-pxa board files.
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This converts the WM97xx driver to use a GPIO descriptor
instead of passing a GPIO number thru platform data.
Like everything else in the driver, use a simple local
variable for the descriptor, it can only ever appear in
one instance anyway so it should not hurt.
After converting the driver I noticed that none of the
boardfiles actually define a meaningful GPIO line for
this, but hey, it is converted.
Cc: Haojian Zhuang <haojian.zhuang@gmail.com>
Cc: Robert Jarzmik <robert.jarzmik@free.fr>
Cc: linux-arm-kernel@lists.infradead.org
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Reviewed-by: Daniel Mack <daniel@zonque.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This converts the Palm Z2 battery driver to use GPIO descriptors.
Cc: Haojian Zhuang <haojian.zhuang@gmail.com>
Cc: Robert Jarzmik <robert.jarzmik@free.fr>
Cc: linux-arm-kernel@lists.infradead.org
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Reviewed-by: Daniel Mack <daniel@zonque.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This driver provides poweroff and reboot support for a system through
the ATC2603C and ATC2609A chip variants of the Actions Semi ATC260x
family of PMICs.
Signed-off-by: Cristian Ciocaltea <cristian.ciocaltea@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The only usage of it is to put its address in an array of pointers to
const static structs. Make it const to allow the compiler to put it in
read-only memory.
Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The only usage of it is to put its address in an array of pointers to
const static structs. Make it const to allow the compiler to put it in
read-only memory.
Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Add support for the LTC4162-L Li-Ion battery charger. The driver allows
reading back telemetry and to set some charging options like the input
current limit.
Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
The MAX8903 uses up to 5 different GPIO lines to control and
monitor charging.
When converting to use GPIO descriptors instead of the old
GPIO numbers the following side-refactorings were done:
- Decomission the platform data container struct as all
GPIO descriptors are now "live" members of the driver
state container. The "dc_valid" and "usb_valid" just
indicate the presence of a DC or USB charger detection
line, and this can be handled by just checking if
the optional GPIO descriptor for each is != NULL.
- The gpiolib will now respect the GPIO_ACTIVE_LOW flag
for each of the lines, meaning gpiod_get_value() for example
will return 1 (asserted) if a line is flagged as
active low and is also physically low. The same applies
to output lines, vice versa mutatis mutandis. The code
has been augmented to account for this in all sites.
- The terse parenthesis such as this:
gpio_set_value(pdata->cen, ta_in ? 0 :
(data->usb_in ? 0 : 1));
have been expanded to more readable if / else if / else
statements that are easier for humans to read.
- Comments were inserted to underscore polarity in each
case where it could be confusing to users of the old code.
One thing is notable: the device tree bindings does not show
an example of polarity assigned for the line "dcm-gpios"
DC current monitor, is assumed to be flagged GPIO_ACTIVE_HIGH
and driving it high (asserted) will achieve DC charger current
limits and driving it low will achieve USB charger current
limits. Device trees with this (optional) GPIO line defined
should definately be flagged as GPIO_ACTIVE_HIGH.
Cc: Chris Lapa <chris@lapa.com.au>
Cc: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>