The ADM series of hotswap controllers support extending
the current measurement range by using a sensing resistor
value other than the typical 1 mOhm. For example, using a 0.5 mOhm
sensing resistor doubles the maximal current can be measured.
Current driver assumes a shunt resistor value of 1 mOhm in calculation,
meaning for other resistor values, hwmon will report scaled
current/power measurements. This patch parses device tree parameter
"shunt-resistor-micro-ohms", if there is one.
Signed-off-by: Kun Yi <kunyi@google.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
A negative page register value means that no page needs to be
selected. This is used by status register read operations and needs
to be accepted. The failure to do so so results in missed status
and limit registers.
Fixes: da8e48ab48 ("hwmon: (pmbus) Always call _pmbus_read_byte in core driver")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Seems like coefficient values for m, b and R under power have been
put in the wrong order. Rearranging them properly to get correct
values of coefficients for power.
For specs, please refer to table 7 (page 35) on
http://www.analog.com/media/en/technical-documentation/data-sheets/ADM1075.pdf
Fixes: 904b296f30 ("hwmon: (adm1275) Introduce configuration data structure for coeffcients")
Signed-off-by: Shikhar Dogra <shidogra@cisco.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
The adm1278 can optionally monitor the VOUT pin. This functionality is
not enabled at reset, so PMON_CONFIG needs to be modified in order to
enable it.
Signed-off-by: Yi Li <adamliyi@msn.com>
Signed-off-by: Joel Stanley <joel@jms.id.au>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
ADM1278 is mostly compatible to other chips of the same series.
Besides the usual difference in coefficients, it supports
a temperature sensor, and it can measure both input and output
voltage at the same time.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
ADM1293 and ADM1294 are mostly compatible with other chips of the same
series, but have more configuration options. There are also some
differences in register details.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Introduce have_vout, have_vaux_status, have_pin_max, and have_uc_fault
to simplify adding support for new chips.
Also simplify error returns where appropriate to return immediately
on error.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Each new chip supported by the driver has a new set of coefficients,
making hard-coding coefficients more and more cumbersome. Introduce
a datastructure and table to simplify configuration.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Since devm_kzalloc() is now used to allocate driver memory, the client
driver remove function has no purpose other than to call pmbus_do_remove().
This means we can get rid of it by redefining pmbus_do_remove() to use the
same prototype, and pointing to it directly.
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This patch converts the drivers in drivers/hwmon/* to use the
module_i2c_driver() macro which makes the code smaller and a bit simpler.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Cc: Corentin Labbe <corentin.labbe@geomatys.fr>
Cc: Dirk Eibach <eibach@gdsys.de>
Cc: "Mark M. Hoffman" <mhoffman@lightlink.com>
Cc: Steve Glendinning <steve.glendinning@smsc.com>
Cc: Riku Voipio <riku.voipio@iki.fi>
Cc: Guillaume Ligneul <guillaume.ligneul@gmail.com>
Cc: David George <david.george@ska.ac.za>
Cc: "Hans J. Koch" <hjk@hansjkoch.de>
Cc: Marc Hulsman <m.hulsman@tudelft.nl>
Cc: Rudolf Marek <r.marek@assembler.cz>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Since manufacturer and device ID are known, read and validate it.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
[Dan Carpenter <dan.carpenter@oracle.com>: Fixed memory leak]
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Always call _pmbus_read_byte() instead of pmbus_read_byte() in PMBus core
driver. With this change, device specific read functions can be implemented for
all registers.
Since the device specific read_byte function is now always called, we need to be
more careful with page validations. Only fail if the passed page number is larger
than 0, since -1 means "current page".
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
ADM1276 is mostly compatible to ADM1275, with added support for input power
measurement. Add support for it to the ADM1275 driver.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
ADM1275 supports a second current limit, which can be configured as either lower
or upper limit. Add support for it and report it as either lower or upper
critical current limit.
Also replace error return code EINVAL for unsupported pages with ENXIO as this
is more appropriate for the observed condition.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Driver remove functions have an error return value, but rarely return an error
in practice. If a driver does return an error from its remove function, the
driver won't be unloaded and is expected to stay alive.
pmbus_do_remove() is defined as returning an int, but always returns 0 (no
error). Calling code passes that return value on to high level driver
remove functions, but does not evaluate it and removes driver data even if
pmbus_do_remove() returned an error (which it in practice never does). Even if
this code could never cause a real problem, it is nevertheless conceptually
wrong.
To reduce confusion and simplify the code, change pmbus_do_remove() to be a void
function, and have PMBus client drivers always return zero in their driver
remove functions.
Reported-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Add support for voltage and current peak (historic maximum) attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
In VID mode, output voltages are measured and reported as VID values, and
have to be converted to voltages using VID conversion tables or functions.
Support is added for VR11 only at this time.
This patch enables support for PMBus devices supporting VID VR11 based output
voltage selection such as NCP4200 and NCP4208.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>