The QFN package is a new one.
There is a different initial setting to the chip of QFN and WLCSP package.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20200116091854.18095-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
Typically, the r0 (calibration data) and temperature were measured in the factory.
This information is written into the non-volatile area
where keeps data whether factory reset or OS update.
In Chromium OS case, the coreboot will read the info from VPD and create
the device property for each rt1011.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Tested-By: Cheng-Yi Chiang <cychiang@chromium.org>
Link: https://lore.kernel.org/r/20191016085845.11672-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
The factory test needs to know whether the calibration completed.
This flag helps to confirm the calibration completed or not.
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20190806091459.14382-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>
- The user level application could set the R0 temperature after booting system.
The degree Celsius of R0 temperature store in the non-volatile space
when doing R0 calibration.
- TDM1 ADC2DAT Swap controls use to control TDM slot2/3 data
Signed-off-by: Shuming Fan <shumingf@realtek.com>
Link: https://lore.kernel.org/r/20190806091435.14329-1-shumingf@realtek.com
Signed-off-by: Mark Brown <broonie@kernel.org>